Menu
Your Cart

BACnet MSTP to Modbus RTU converters - Efficient automation integration

BACnet MSTP to Modbus RTU Converters - Reliable Solutions for Industrial Automation

BACnet MSTP to Modbus RTU converters are advanced devices that provide efficient data exchange between systems based on BACnet MSTP and Modbus RTU protocols. The BACnet MSTP protocol is widely used in building automation, supporting HVAC management, lighting control, fire detection and alarm systems, power supply and CCTV monitoring. As one of the most popular protocols in industrial control systems, Modbus RTU is often used in devices such as PLCs and SCADA systems. With BACnet MSTP to Modbus RTU converters, it is possible to easily integrate the two standards, allowing central monitoring and control of diverse systems.

Versatility and reliability in demanding environments

Our BACnet MSTP to Modbus RTU converters are designed to operate reliably in a wide variety of industrial environments. Thanks to their immunity to electromagnetic interference, they are used in environments with high electromagnetic field strengths, such as production facilities and server rooms. Their wide operating temperature range, from -40°C to 85°C, makes them suitable for both indoor and outdoor installations. The robust design and the ability to be quickly and securely mounted on a DIN rail ensure easy installation and a long service life for the devices, even in harsh industrial environments.

Intuitive configuration and advanced features

Every BACnet MSTP to Modbus RTU converter available in our range comes with free software for easy device configuration. Intuitive tools allow you to quickly adjust parameters such as baud rate, data priorities or RS-232, RS-485 and Ethernet connector configuration. This makes the integration of BACnet MSTP devices into Modbus RTU systems efficient. The universal communication interfaces ensure wide compatibility, enabling interfacing with a variety of devices.

BACnet MSTP to Modbus RTU converter applications

  • Building automation: Integration of HVAC, lighting control, access control and fire alarm systems with Modbus RTU devices.
  • SCADA and monitoring systems: Seamless data exchange between BACnet MSTP devices and Modbus RTU-capable PLCs.
  • Infrastructure upgrades: Enabling new devices to interface with existing installations based on Modbus RTU and BACnet MSTP.
  • Industrial control systems: Production process management, equipment monitoring and industrial system automation.
  • Protocol integration: Efficient synchronisation of Modbus RTU and BACnet MSTP systems in a single, consistent automation environment.

Why choose our converters?

Our BACnet MSTP to Modbus RTU converters are distinguished by their reliability, flexibility and ease of configuration. They make it possible to connect devices from different manufacturers, allowing you to efficiently expand your existing automation systems. Key benefits include:

  • Resistance to electromagnetic interference.
  • Robust design and wide operating temperature range.
  • Ease of installation thanks to DIN rail mounting.
  • Free, intuitive configuration software.
  • Compatibility with popular interfaces such as RS-232, RS-485 and Ethernet.

Contact our team of experts

If you need help selecting the right BACnet MSTP to Modbus RTU converter or have questions about our products, please contact us. Our specialists will be happy to advise you and help you choose the best solution to suit your needs. Contact us today and find out how our converters can enhance your automation systems.

HD67671-MSTP-2-A1 - BACnet MSTP slave to RS-232 Modbus Master converter, slim housing A, DIN rail mount, 2000 BACnet objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67671-MSTP-2-A1
Industrial BACnet MSTP slave to RS-232 Modbus master converter, housing type A (slim), DIN rail mount.HD67671 allows you to connect a BACnet Master (for example a Supervisory System, etc) with some Modbus slaves. Converter is easy to configure thanks to free SW676..
329.00 €
HD67671-MSTP-4-A1 -  BACnet MSTP slave to Modbus master converter, housing type A, DIN rail mount, 2000 BACnet objects HD67671-MSTP-4-A1 -  BACnet MSTP slave to Modbus master converter, housing type A, DIN rail mount, 2000 BACnet objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67671-MSTP-4-A1
Industrial BACnet MSTP slave to RS-485 Modbus master converter, housing type A (slim), DIN rail mount.HD67671 allows you to connect a BACnet Master (for example a Supervisory System, etc) with some Modbus slaves. Converter is easy to configure thanks to free SW6767..
329.00 €
HD67672-MSTP-2-A1 - BACnet MSTP slave to RS-232 Modbus slave converter, slim DIN rail converter, up to 2048 objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67672-MSTP-2-A1
Industrial BACnet MSTP slave to RS-232 Modbus slave converter, housing type A (slim), DIN rail mount.HD67672 allows you to connect a BACnet Master (for example a Supervisory System, etc) with a Modbus Master (for example a PLC, HMI, etc) in order to exchange the in..
329.00 €
HD67672-MSTP-4-A1 - BACnet MSTP slave to RS-485 Modbus slave converter, housing type A, DIN rail mount, 2048 objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67672-MSTP-4-A1
Industrial BACnet MSTP slave to RS-485 Modbus slave converter, housing type A (slim), DIN rail mount.HD67672 allows you to connect a BACnet Master (for example a Supervisory System, etc) with a Modbus Master (for example a PLC, HMI, etc) in order to exchange the in..
329.00 €
HD67712-MSTP-2-A1 - BACnet MSTP master to RS-232 Modbus slave converter, housing type A, DIN rail mount, 1024 objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67712-MSTP-2-A1
Industrial BACnet MSTP master to RS-232 Modbus slave converter, housing type A (slim), DIN rail mount.HD67712 is a BACnet Master / Modbus Slave Converter and it allows you to connect some BACnet slaves with a Modbus Master (for example a PLC, HMI). Converter is ea..
329.00 €
HD67712-MSTP-4-A1 - BACnet MSTP master to RS-485 Modbus slave converter, housing type A (slim), DIN rail mount, 1024 objects
2 years warranty 3-4 days
Brand: ADF Web Model: HD67712-MSTP-4-A1
Industrial BACnet MSTP master to RS-485 Modbus slave converter, housing type A (slim), DIN rail mount.HD67712 is a BACnet Master / Modbus Slave Converter and it allows you to connect some BACnet slaves with a Modbus Master (for example a PLC, HMI). Converter is ea..
329.00 €
IN7004851000000 - Modbus RTU/TCP to BACnet Gateway 100 Points
3 years warranty 5-7 days
Brand: Intesis Model: IN7004851000000
Industrial Modbus RTU/TCP to BACnet Gateway (100 points).  The IN7004851000000 model is a compact yet highly functional gateway that enables bidirectional integration of Modbus RTU or TCP devices with BACnet systems – supporting both BACnet IP and MS/TP. It is ide..
649.00 €
INBACMBM2500000 - Modbus RTU or TCP to BACnet Gateway 250 Points
3 years warranty 5-7 days
Brand: Intesis Model: INBACMBM2500000
INModbus RTU or TCP to BACnet Gateway 250 points. The INBACMBM2500000 gateway from Intesis is an industrial-grade solution designed to enable seamless integration of Modbus RTU and Modbus TCP slave devices into BACnet-based systems. This versatile gateway suppor..
1,007.00 €
INBACMBM6000000 - Modbus RTU/TCP to BACnet IP/MSTP Gateway 600 Points
3 years warranty 5-7 days
Brand: Intesis Model: INBACMBM6000000
Modbus RTU/TCP to BACnet IP/MSTP Gateway 600 Points. The INBACMBM6000000 gateway from Intesis (HMS Networks) enables transparent, bidirectional integration of Modbus RTU and Modbus TCP slave devices into BACnet ecosystems supporting BACnet IP and BACnet MS/TP. W..
1,164.00 €
INBACMBM1K20000 - Modbus RTU or TCP to BACnet Gateway 1200 Points
3 years warranty 5-7 days
Brand: Intesis Model: INBACMBM1K20000
Modbus RTU or TCP to BACnet Gateway 1200 Points. The INBACMBM1K20000 gateway by Intesis (previously IBOX-BAC-MBM) is a powerful and compact solution that enables seamless integration of Modbus RTU and Modbus TCP slave devices with BACnet-based building automatio..
1,947.00 €
INBACMBM3K00000 - Modbus RTU or TCP to BACnet Gateway 3000 Points
3 years warranty 5-7 days
Brand: Intesis Model: INBACMBM3K00000
Modbus RTU or TCP to BACnet Gateway 3000 points. The INBACMBM3K00000 gateway offers seamless integration of Modbus RTU and Modbus TCP slave devices into BACnet IP or BACnet MS/TP-based systems. It supports up to 3000 data points, making it ideal for large-scale ..
2,754.00 €
Showing 1 to 11 of 11 (1 Pages)