CANopen Slave Module with 16 Isolated Open Collector Digital Outputs. CAN-2057C module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital input status and set the configuration by using standard CANopen protocol. CAN-2057C has passed the validation of the CiA CANopen..
CANopen slave module with 16 Isolated Digital Inputs (Sink/Source). CAN-2053C module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital input status and set the configuration by using standard CANopen protocol. CAN-2053C has passed the validation of the CiA CANopen C..
CANopen Slave Module with 8 Digital Inputs and 8 Digital Outputs. CAN-2054C module follows the CiA DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2054C has passed the validation of the CiA CANopen c..
CANopen Slave Module with 8 Digital Inputs and 8 Digital Outputs. CAN-2055C module follows the CiA-301 version 4.02 and CiA-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2055C has passed the validation of the CiA CANopen conf..
CANopen I/O module with 4 Digital Inputs and 4 Relay Outputs. CAN-2060C module follows the CiA-301 version 4.02 and CiA-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2060C has passed the validation of the CiA CANopen conforma..
CANopen Slave Module with 8 PWM and 8 Digital Inputs with High-Speed Counters. PWM (Pulse width modulation) is a powerful technique for controlling analog circuits. It uses digital outputs to generate a waveform with variant duty cycle and frequency to control analog circuits. CAN-2088C is a PWM sla..
CANopen Remote I/O Unit with 2 Expansion Slots. The CAN-8x23 main control unit is specially designed for the slave device of CANopen protocol. It follows the CANopen Spec DS-301 V4.02 and DSP-401 V2.1, and supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC c..
DeviceNet Remote I/O Unit with 2 I/O Expansion Slots. The CAN-8124/CAN-8224 main control unit is specially designed for the slave device of DeviceNet protocol. It follows the Specification of DeviceNet. In order to expand I/O channel more flexible, an CAN-8x24 supports 1/2/4 slot(s) for I/O expansio..
CANopen Slave Module with 8 Differential Analog Inputs. CANopen is one kind of the network protocols based on the CAN bus and mainly used for embedded network system, such as industrial machine control , vehicle control system, factory automation, medical equipment control, remote data acquisition, ..
CANopen Slave Module with 8 Thermocouple Inputs. Include CAN-2018C module and a CN-1824 daughter board. CAN-2018C/S module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the thermocouple input status and set the configuration by using standard CANopen protocol. CAN-2018C/S h..
CANopen slave module with 6 Analog Inputs, 2 Analog Outputs, 1 Digital Output and 2 Digital Inputs. CAN-2026C module follows the CiA-301 version 4.02 and CiA-401 version 2.1. You can access the analog/digital I/O status and set the configuration by using standard CANopen protocol. CAN-2026C has pass..
CANopen Slave Module with 10 Universal Analog Inputs. Include CAN-2019C module and a DB-1820 daughter board. CAN-2019C/S module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the thermocouple input status and set the configuration by using standard CANopen protocol. CAN-2019..
CANopen slave module with 8 Analog RTD Inputs. CANopen is one kind of the network protocols based on the CAN bus and mainly used for embedded network system, such as industrial machine control, vehicle control system, factory automation, medical equipment control, remote data acquisition, environmen..
CANopen Slave Module with 4 Analog Outputs. The CAN-2024C module follows the CiA DS-301 version 4.02 and DSP-401 version 2.1. It is easy to access the analogue I/O status and set the configuration by using the standard CANopen protocol. The CAN-2024C has passed the validation of the CiA CANopen Conf..
CANopen Remote I/O Unit with 4 Expansion Slots. The CAN-8x23 main control unit is specially designed for the slave device of CANopen protocol. It follows the CANopen Spec DS-301 V4.02 and DSP-401 V2.1, and supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC c..
DeviceNet Remote I/O Unit with 4 I/O Expansion Slots. The CAN-8124/CAN-8224 main control unit is specially designed for the slave device of DeviceNet protocol. It follows the Specification of DeviceNet. In order to expand I/O channel more flexible, an CAN-8x24 supports 1/2/4 slot(s) for I/O expansio..
CANopen Remote I/O Unit with 8 Expansion Slots. The CAN-8x23 main control unit is specially designed for the slave device of CANopen protocol. It follows the CANopen Spec DS-301 V4.02 and DSP-401 V2.1, and supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC c..