Znajdź produkty TELE-FONIKA Kable w najniższych cenach.

Zdjęcie TELE-FONIKA Kable

OnGcrekgż-G (Z) 6/10 kV
To be confirmed
Brand: TELE-FONIKA Kable Model: OnGcrekgż-G (Z) 6/10 kV
Mining wires shielded for rated voltage 6/10 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989The color of the insulation of the veins: NaturalScreen on the insulation of working cores: GP semiconductor rubber according to PN-E 29100: 1989Tire..
0,00 zł
OnZGcekż-GW (A) 0.6/1 kV
To be confirmed
Brand: TELE-FONIKA Kable Model: OnZGcekż-GW (A) 0.6/1 kV
Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV. Construction:Working, protective and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228Separator: On operating wires made of polyester filmInsulation: IEP heat-resistant rubber according to PN-89 / E-29100Screen on the working veins and on the sheath of the auxiliary veins: In the form of a roll with a conductive band and a braid of..
0,00 zł
OpGcrekgż-G (S) 6/10 kV
To be confirmed
Brand: TELE-FONIKA Kable Model: OpGcrekgż-G (S) 6/10 kV
Mining wires shielded for rated voltage 6/10 kV. Construction:Working and protective conductors: Copper multi-wire classes 5 or 5c according to PN-E-90160: 1988Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989The color of the insulation of the veins: NaturalScreen on the insulation of working cores: GP semiconductor rubber according to PN-E 29100: 1989..
0,00 zł
OpnZGcekż-G 0.6/1 kV
To be confirmed
Brand: TELE-FONIKA Kable Model: OpnZGcekż-G 0.6/1 kV
Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV.Construction:Working, protective and auxiliary cores: Copper tinned multi-wire class 5 acc. PN-EN 60228Separator: Coils made of polyester film on working veinsInsulation: IEP heat-resistant rubber according to PN-89 / E-29100Color of insulation:Working: blue, natural, red3 auxiliary: blue, natural, red6 auxiliary: 2 blue, 2 natural, 2 redScreen on w..
0,00 zł
PSKD
To be confirmed
Brand: TELE-FONIKA Kable Model: PSKD
Field fiber optic cables for special applications. PSKD fiber optic cables are lightweight and durable (max. Tensile force 2.5 kN) thanks to the use of two layers of aramid fiber reinforcement. Exceptional flexibility of cables, especially at low temperatures (a positive test of 100,000 rewinding cycles) has been achieved by using a special material such as polyurethane. The use of polyurethane in the flameproof version means that the cables can ..
0,00 zł
PSY
To be confirmed
Brand: TELE-FONIKA Kable Model: PSY
Flat shot wire. Construction:Wire: Copper wire type Dm with properties according to PN-83 / E-90150Structure of the wire: 35x0.25 mm according to WT-77 / K-095Diameter of the wire: 1.75 mmInsulation: Made of plain PVC's SG (acc. To PN-C-89265-2: 1998)Insulation thickness: Rated 0.8 mm, negative deviations of thickness should not exceed 0.1 mm + 10% of the nominal thicknessInsulation color: Red and greenCenter: Two insulated conductors arranged in..
0,00 zł
RPX, YRPX, YnRPX
To be confirmed
Brand: TELE-FONIKA Kable Model: RPX, YRPX, YnRPX
Radio lines. RPX - radio (P) cable (R) with polyethylene insulation (X). YRPX - a (P) broadcast cable (R) with polyethylene insulation (X) and a PVC (Y) sheath. YnRPX - radio (P) cable (R) with polyethylene isolation (X) and flame retardant polyvinyl chloride (Yn).Characteristic:Example of marking: TFKABLE 1 RPX 2x0,9 / year of production / metric print every 1 meterApplication: The cables are designed for making radio installations inside buildi..
0,00 zł
S-XOTKtsd
To be confirmed
Brand: TELE-FONIKA Kable Model: S-XOTKtsd
Optotelecommunications tube cables, self-supporting, octal.S-XOTKtsd - self-supporting cable, figure-eight (S), with polyethylene (X) coating, optotelecommunication (OTK), horn (loose tube), with dry center seal (ts), completely dielectric support element (d).Construction:Optical fiber:Singlemode (J)Singlemode with non-zero offset dispersion (Jn)Multimode (G/50)Multimode (G/62.5)Tube: Central with optical fibers, filled with thixotropic gelSealin..
0,00 zł
SDY 1x0.6, 1x0.75, 2x0.6
To be confirmed
Brand: TELE-FONIKA Kable Model: SDY 1x0.6, 1x0.75, 2x0.6
Protective shot wire. Construction:Veins: Round solid one; Diameter 0.6 mm, 0.75 mmInsulation: PVC, Colors of insulation according to ZN-TF-50, Thickness: 0.6 mm, 0.75 mmCenter: Insulated wire of copper wire or two twisted insulated wiresCharacteristic:Application: A protective blasting cable for connecting the circuits of electric fuses with a blasting line in all mining plants where blasting works are performed, including in the methane fields ..
0,00 zł
SF/UTP
To be confirmed
Brand: TELE-FONIKA Kable Model: SF/UTP
Shielded teleinformation cables. Category 6 teleinformation cables with steam bundles, with a core insulation made of polyethylene or foam with a single layer of polyethylene, screened, with a coating made of PVC. The cable center is protected with an estropholic film, an estrofolic film screen sprayed with aluminum and covered with a screen made of a mesh of tinned copper wires.Construction:Cable wires: Soft copper wireCore insulation: Solid pol..
0,00 zł
SIF 300/500V
To be confirmed
Brand: TELE-FONIKA Kable Model: SIF 300/500V
Single-core cables with silicone rubber insulation. Designed for use in places with high ambient temperature, for internal wiring of lighting fixtures, control devices and distributors and heating devices.They do not contain halogens, have a high flash point, very good dielectric properties at elevated temperatures, high resistance to many chemicals (oxygen, ozone, vegetable and animal fats, vegetable oils, soap solutions, alcohols, ammonia, weak..
0,00 zł
SY 1x1.2 mm
To be confirmed
Brand: TELE-FONIKA Kable Model: SY 1x1.2 mm
Shot wire. Construction:Veins: One-round round, 1.2 mm diameterInsulation: PVC, natural color, 0.8 mm thickCharacteristic:Application: Blasting cable for connecting the circuits of electric detonators with a blasting line in all mining plants where blasting works are performedWire veil resistance at 20 ° C, max .: 5.5 Ohm / 100 mInsulation resistance: 20 MOhm x kmInsulation resistance for test voltage: 5000 V; 1 minute, constant voltageMinimum be..
0,00 zł