Search
Search Criteria
Products meeting the search criteria
Brand: ADF Web
Model: HD67117-A4
Isolated CANopen bus line extender, CANopen bus repeater. Housing type A (slim), Mini-Fit Connectors, Galvanic Isolation: 3KV, DIN rail mount. Characteristics:Resolves your extension line problemsIdeal for galvanized isolationDifferent transmission speed settings possible (in different branches)Mountable on DIN railInterconnects two branches of different speedsAdapted for use in motors and devices with electromagnetic disturbancesSpecifications:P..
925.90 zł
Brand: ADF Web
Model: HD67117M
Isolated CANopen bus line extender, CANopen bus repeater. Housing type: Small Size, Terminal Blocks Connetors, DIN rail mount. Characteristics:Resolves your extension line problemsIdeal for galvanized isolationDifferent transmission speed settings possible (in different branches)Mountable on DIN railInterconnects two branches of different speedsAdapted for use in motors and devices with electromagnetic disturbancesSpecifications:Ports: 2x CANCAN2..
925.90 zł
Brand: ADF Web
Model: HD67117R
Isolated CANopen bus line extender, CANopen bus repeater. Housing type R, DIN rail mount, terminal blocks connectors, galvanic isolation: 3KVCharacteristics:Resolves your extension line problemsIdeal for galvanized isolationDifferent transmission speed settings possible (in different branches)Mountable on DIN railInterconnects two branches of different speedsAdapted for use in motors and devices with electromagnetic disturbancesSpecifications:Por..
925.90 zł
Brand: ADF Web
Model: HD67181-A4
Industrial isolated CAN 2.0A and 2.0B bus line extender, CAN bus repeater, housing type A (slim), Mni-Fit Connectors, Galvanic Isolation: 3KV, DIN rail mount. Characteristics:Resolves your extension line problemsIdeal for galvanized isolationDifferent transmission speed settings possible (in different branches)Mountable on DIN railInterconnects two branches of different speedsAdapted for use in motors and devices with electromagnetic disturbances..
925.90 zł
Brand: ADF Web
Model: HD67181R
Industrial CAN to Repeater, Extender bus line. Housing type: R, Terminal Blocks Connectors, Galvanic Isolation: 3KV HD67181R is repeater with a 3kV isolation between the two CAN bus.Characteristics:Electrical isolation ISO 11898/ISO IEC 11801Allows extension of a line segment (without lowering the Baud Rate)Possible different baud rate setting (into different branches)Multi-Mode Optic Fiber up to 2000 metersSpecificactions:Ports: 2xCANData Rates ..
925.90 zł
Brand: ICPDAS
Model: CAN-2057C CR
CANopen Slave Module with 16 Isolated Open Collector Digital Outputs. CAN-2057C module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital input status and set the configuration by using standard CANopen protocol. CAN-2057C has passed the validation of the CiA CANopen Conformance Test tool. Therefore, you can use it with standard CANopen master easily by applying the EDS file. CAN-2057C has 16-channel isolated o..
991.70 zł
Brand: ICPDAS
Model: CAN-2053C CR
CANopen slave module with 16 Isolated Digital Inputs (Sink/Source). CAN-2053C module follows the DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital input status and set the configuration by using standard CANopen protocol. CAN-2053C has passed the validation of the CiA CANopen Conformance Test tool. Therefore, you can use it with standard CANopen master easily by applying the EDS file. CAN-2053C has 16-channel isolated sin..
1,019.90 zł
Brand: ICPDAS
Model: CAN-2054C CR
CANopen Slave Module with 8 Digital Inputs and 8 Digital Outputs. CAN-2054C module follows the CiA DS-301 version 4.02 and DSP-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2054C has passed the validation of the CiA CANopen conformance test tool. Therefore, you can use it with standard CANopen master easily by applying the EDS file. CAN-2054C has isolated sink/source in..
1,048.10 zł
Brand: ICPDAS
Model: CAN-2055C CR
CANopen Slave Module with 8 Digital Inputs and 8 Digital Outputs. CAN-2055C module follows the CiA-301 version 4.02 and CiA-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2055C has passed the validation of the CiA CANopen conformance test tool. Therefore, you can use it with standard CANopen master easily by applying the EDS file. CAN-2055C has 8 isolated sink/source inp..
1,048.10 zł
Brand: ICPDAS
Model: CAN-2060C CR
CANopen I/O module with 4 Digital Inputs and 4 Relay Outputs. CAN-2060C module follows the CiA-301 version 4.02 and CiA-401 version 2.1. You can access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2060C has passed the validation of the CiA CANopen conformance test tool. Therefore, you can use it with standard CANopen master easily by applying the EDS file. CAN-2060C has 4 isolated sink/source input c..
1,048.10 zł
Brand: ICPDAS
Model: CAN-2088C CR
CANopen Slave Module with 8 PWM and 8 Digital Inputs with High-Speed Counters. PWM (Pulse width modulation) is a powerful technique for controlling analog circuits. It uses digital outputs to generate a waveform with variant duty cycle and frequency to control analog circuits. CAN-2088C is a PWM slave module of CANopen protocol. It has 8 PWM output channels and 8 high speed counter channels. It can be used to develop powerful and cost effective a..
1,264.30 zł
Brand: ADF Web
Model: HD67042-A1
Industrial CAN to CANopen converter, housing type A (slim), DIN rail mount. HD67042-A1 allows the communication between CAN and CANopen networks, converter automaticly generates GSD file that allows to integrate the converter to the system very quickly. Converter is easy to install and configure thanks to free SW67042 software.Configuration:Thanks to the SW67042 software on your PC you can:Define the parameters of CAN lineDefine the parameters of..
1,287.80 zł