Search
Search Criteria
Products meeting the search criteria
Brand: TELE-FONIKA Kable
Model: FLAME-X 950 NKOGs 0,6/1 kV
Halogen-free and fire-resistant electric ship cables with low smoke emission. Compliant with IEC 60092-353. Construction:Conductors: Circular or circular compacted stranded bare or tinned copper class 2 acc. to IEC 60228Insulation: Special cross-linked compound HF S 95 acc. to IEC 60092-351Inner covering:special flame-retardant, halogen-free compound for cables up to 16 mm2tape bedding and special flame-retardant, halogen-free compound for cables..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FLAME-X 950 NKOGsekw 0,6/1 kV
Halogen-free and fire retardant low-emission marine power cables, shielded. Compliant with IEC 60092-353. Construction:Conductors: Circular or circular compacted stranded bare or tinned copper class 2 acc. to IEC 60228Insulation: Special cross-linked compound HF S 95 acc. to IEC 60092-351Inner covering:special flame-retardant, halogen-free compound for cables up to 16 mm2tape bedding and special flame-retardant, halogen-free compound for cables 2..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FLAME-X 950 NTKOGsekw (IB) 150/250V (300V)
Halogen-free and fire-resistant telecommunication, measuring and signaling ship cables with low smoke emission jointly shielded with copper wires. Compliant with IEC 60092-376.Construction:Core: Copper bare or tinned round multi-wire class 2 according to IEC 60228Insulation: Special crosslinked HF S 95 mixture according to IEC 60092-351Armor (screen): Braid made of copper wires in contact with a grounding wire made of copper wiresFilling: Tape or..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FLAME-X 950 NTKOGsekwf 150/250V (300V)
Halogen-free and fire-proof telecommunication, measuring and signaling ship cables with low smoke emission jointly shielded with aluminum-polyester tape. Compliant with IEC 60092-376. Construction:Conductors: Circular stranded tinned copper class 5 acc. to IEC 60228Insulation: Special cross-linked compound HF S 95 acc. to IEC 60092-351Inner covering: Lapped with non-hygroscopic tapeCollective screen: Of aluminium/polyester tape with the metallic ..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker KONS 0,6/1 kV
Halogen-free low-emission marine power cable, single-core. Compliant with IEC 60092-353. Construction:Conductors: Copper bare or tinned multi-wire flexible class 5 according to IEC 60228Insulation: Halogen- free polyolefin compound type HF 90 acc. to IEC 60092-351Colour of Insulation: Black, red, blue, white, green/yellow, Outer suitable colour may be usedTechnical Data:Maximum conductor operating temperature: +90°CLowest ambient temperature for ..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NKOXS 0,6/1 kV
Halogen-free low-emission marine power cable, single and multi-core. Compliant with IEC 60092-353. Construction:Conductors:circular stranded bare or tinned copper class 2 1 to 6 mm2circular compacted stranded bare or tinned copper class 2 10 to 300 mm2circular stranded bare or tinned copper class 5sector shaped 35 to 300 mm2 acc. to IEC 60228Insulation: Cross-linked polyethylene HF XLPE 90°C, > 35 mm2 cross-linked polyolefin compound HF 90 acc..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NKOXSekw 0,6/1 kV
Halogen-free electric ship cables with low smoke emission, single and multi-wire shielded. Compliant with IEC 60092-353. Construction:Conductors:circular stranded bare or tinned copper class 2 1 to 6 mm2circular compacted stranded bare or tinned copper class 2 10 to 300 mm2circular stranded bare or tinned copper class 5sector shaped 35 to 300 mm2 acc. to IEC 60228Insulation: Cross-linked polyethylene HF XLPE 90°C, > 35 mm2 cross-linked polyole..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NTKOXSekf/ekw 150/250V (300V)
Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, with pairs (triples) individually shielded with aluminum-polyester tape and collectively shielded with copper wires. Construction:Conductors: Circular stranded copper class 2 acc. to IEC 60228Insulation: Cross-linked polyethylene HF-XLPE 90°C acc. to IEC 60092-351Individually pair screen: Of aluminium/polyester tape with the metallic contact with a tinned..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NTKOXSekf/ekw IB 150/250V (300V)
Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, with pairs (triples) individually shielded with aluminum-polyester tape and jointly shielded with copper wires (with extruded internal IB filling). Construction:Conductors: Circular stranded copper class 2 acc. to IEC 60228Insulation: Cross-linked polyethylene HF-XLPE 90°C acc. to IEC 60092-351Individually pair screen: Of aluminium/polyester tape with the..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NTKOXSekf/ekwf 150/250V (300V)
Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, with vapor in individually shielded aluminum-polyester tape and jointly shielded with aluminum-polyester tape. Construction:Conductors: Circular stranded bare or tinned copper class 2 or class 5 acc. to IEC 60228Insulation: Cross-linked polyethylene HF-XLPE 90°C acc. to IEC 60092-351Individually pair screen: Of aluminium/polyester tape with the metallic c..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NTKOXSekw 150/250V (300V)
Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, multi-core or multi-pair (three-phase), jointly shielded with copper wires. Compliant with IEC 60092-376. Construction:Conductors: Circular stranded bare or tinned copper class 2 or class 5 acc. to IEC 60228Insulation: Cross-linked polyethylene HF-XLPE 90ºC acc. to IEC 60092-351Inner covering: Lapped with non-hygroscopic tapeArmour (screen): Copper wire b..
0.00 zł
Brand: TELE-FONIKA Kable
Model: FlameBlocker NTKOXSekw IB 150/250V (300V)
Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, multi-core or multi-pair (triple), jointly shielded with copper wires (with extruded internal IB filling). Construction:Conductors: Circular stranded bare or tinned copper class 2 or class 5 acc. to IEC 60228Insulation: Cross-linked polyethylene HF-XLPE 90ºC acc. to IEC 60092-351Inner covering: Lapped with non-hygroscopic tapeArmour (screen): Copper wire ..
0.00 zł