Industrial MBus to RS232 converter, master Mbus up to 250 slaves, housing type B (wide), DIN rail mount. This series allows to read/write MBus Slaves by RS-232, ensuring galvanic isolation between MBus and RS-232. HD67021 is a configurable device with logic inside and it allows to connect up to 250 MBus Slaves to RS-232. Converter is easy to configure thanks to free SW67021 software.Configuration:Thanks to SW67021 software on your PC you can:Defi..
Industrial MBus to RS485 converter, master MBus up to 250 slaves, housing type B (wide), DIN rail mount. This series allows to read/write MBus Slaves by RS-485, ensuring galvanic isolation between MBus and RS-485. HD67022 is a configurable device with logic inside and it allows to connect up to 250 MBus Slaves to RS-485. Converter is easy to configure thanks to free SW67021 software.Configuration:Thanks to SW67021 software on your PC you can:Defi..
MBus to RS-232 - Converter (for Analog Modem connection, Master MBus: up to 250 slaves), housing type B (wide), DIN rail mount. This series allows to comunicate with the Slaves M‐bus remotely, using an Analog Modem or a GSM Modem. Moreover it is possible to connect directly to the device using a Null‐Modem serial cable. Converter is easy to configure thanks to free SW67023 software.Characteristics:European standard EN 1434Microprocessor controlCo..
Industrial MBus meters analyzer, scanner & sniffer, master MBus up to 250 slaves, housing type B (wide), DIN rail mount. Devices from the series MBus analyzers, scanners allows, among others, on the diagnosis of MBus devices, eavesdropping on bus communication, sending strings and changing the meter settings, such as changing the primary/secondary ID address, changing the transmission speed, etc. (for more information, refer to the instructio..
Industrial MBus Wireless to Modbus TCP Slave Converter, housing type B (wide), DIN rail mount. Support up to 80 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 169MHz, S1&T1 supoprted. The HD67083-B2-169MHz-80 is a MBus Wireless to Modbus TCP Slave Converter and allows you to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a Modbus TCP net (like a PLC, a PC exc). Converter i..
Industrial MBus Wireless to Modbus TCP Slave Converter, housing type B (wide), DIN rail mount. Support up to 80 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 433MHz, S1&T1 supoprted. The HD67083-B2-433MHz-80 is a MBus Wireless to Modbus TCP Slave Converter and allows you to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a Modbus TCP net (like a PLC, a PC exc). Converter is eas..
Industrial MBus Wireless to Modbus TCP Slave Converter, housing type B (wide), DIN rail mount. Support up to 80 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 868MHz, S1&T1 supoprted. The HD67083-B2-868MHz-80 is a MBus Wireless to Modbus TCP Slave Converter and allows you to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a Modbus TCP net (like a PLC, a PC exc). Converter is eas..
Industrial MBus Wireless to BACnet IP Slave Converter, housing type B (wide), DIN rail mount. Support up to 40 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 169MHz, N1&N2 supoprted. HD67086-IP-B2-169MHz-40 allow to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a BACnet net (like a Supervisory System exc). Converter is easy to install and configure thanks to free software SW67..
Industrial MBus Wireless to BACnet IP Slave Converter, housing type B (wide), DIN rail mount. Support up to 40 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 433MHz, S1&T1 supoprted. HD67086-IP-B2-433MHz-40 allow to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a BACnet net (like a Supervisory System exc). Converter is easy to install and configure thanks to free software SW67..
Industrial MBus Wireless to BACnet IP Slave Converter, housing type B (wide), DIN rail mount. Support up to 40 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 868MHz, S1&T1 supoprted. HD67086-IP-B2-868MHz-40 allow to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a BACnet net (like a Supervisory System exc). Converter is easy to install and configure thanks to free software SW67..
Industrial MBus Wireless to BACnet MSTP Slave Converter, housing type B (wide), DIN rail mount. Support up to 40 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 169MHz, N1&N2 supoprted. HD67086-MSTP-B2-169MHz-40 allow to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a BACnet net (like a Supervisory System exc). Converter is easy to install and configure thanks to free software ..
Industrial MBus Wireless to BACnet MSTP Slave Converter, housing type B (wide), DIN rail mount. Support up to 40 MBus slaves and up to 32 MBus Wireless slaves, wMBus @ 433MHz, S1&T1 supoprted. HD67086-MSTP-B2-433MHz-40 allow to monitor some MBus Wireless meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a BACnet net (like a Supervisory System exc). Converter is easy to install and configure thanks to free software ..