IN485MIT001A000 – Mitsubishi Ecodan interface to BACnet MS/TP and Modbus RTU, DIN rail mount

BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
3 year warranty Quantity discount 5-7 days
BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
BACnet MS/TP and Modbus RTU gateway for Mitsubishi Ecodan – IN485MIT001A000 | Intesis
IN485MIT001A000 – Mitsubishi Ecodan interface to BACnet MS/TP and Modbus RTU, DIN rail mount
  • Stock: 5-7 days
  • Brand: Intesis
  • Model: IN485MIT001A000
1,363.00 zł
2 pieces or more 1,294.85 zł
5 pieces or more 1,267.59 zł
10 pieces or more 1,226.70 zł
26 pieces or more 1,158.55 zł
51 pieces or more 1,035.88 zł

IN485MIT001A000 – industrial communication gateway for Mitsubishi Electric Ecodan heat pumps, supporting BACnet MS/TP and Modbus RTU protocols, DIP switch configuration, DIN rail or wall mount.

The IN485MIT001A000 from Intesis enables the integration of Mitsubishi Electric Ecodan air-to-water heat pumps into building management systems using BACnet MS/TP or Modbus RTU. It acts as a gateway that communicates with the Ecodan outdoor unit through a dedicated interface and provides real-time monitoring and control capabilities to the BMS.

The device is powered directly from the Ecodan unit and does not require an external power supply. Configuration is handled entirely via integrated DIP switches (SW1, SW2, SW3), allowing the selection of protocol type (BACnet or Modbus), baud rate, MAC/Slave address, temperature units, and RS-485 bus termination. No additional configuration software is required – the gateway is ready for use immediately after installation.

The gateway provides full two-way communication with a single Mitsubishi Ecodan system and supports over 100 data points including operating mode, zone temperatures, pump and compressor status, energy metering, DHW management, and error codes. It allows simultaneous control via both the original Mitsubishi controller and the building automation system. The integration ensures that all relevant parameters and operating states of the Ecodan unit can be monitored and adjusted remotely from BACnet or Modbus networks.

Certified by BTL (BACnet Testing Laboratories), the gateway ensures full interoperability with BACnet-based systems. It enables control of operating mode (heating/cooling), DHW setpoints, flow temperature, auxiliary heater status, and time-based scheduling (including Holiday mode). The Virtual Temperature function allows the use of external temperature readings from the BMS as reference values for controlling the heat pump.

Advanced monitoring functions include energy consumption in kWh, operating hours, defrost status, refrigerant leak detection, legionella prevention mode, and electric heater operation. All data points are accessible via BACnet objects (AI, AO, BI, BO, MI, MO) or Modbus registers for maximum compatibility across automation systems. LED indicators on the housing provide immediate visual feedback on communication activity and device errors.

Main features:
  • Integration of Mitsubishi Ecodan heat pumps with BACnet MS/TP and Modbus RTU networks.
  • Simple configuration via DIP switches – no software required.
  • Compatible with DHW control and two heating zones.
  • Powered directly from the Ecodan unit – no external power supply needed.
  • Over 100 data points for complete monitoring and control of the heat pump system.
  • Built-in bus termination and galvanic isolation 1000 VDC.
  • DIN rail or wall mounting, compact size 93 × 53 × 58 mm.
  • BTL certified, compliant with CE and RoHS standards.
  • 3-year manufacturer warranty by HMS Intesis.

Technical specifications:
  • Communication interface: BACnet MS/TP or Modbus RTU (EIA-485, 3-pin terminal B-A-SG).
  • Connection to Ecodan unit: dedicated connector (AC Unit port, 1.5 m cable included).
  • Configuration: DIP switches (SW1–SW3) – mode, baud rate, address, temperature, termination.
  • Baud rate: 2400–115200 bps, auto-detection (8-N-1 / 8-N-2).
  • Power supply: from the Ecodan unit (no external power required).
  • Isolation: 1000 VDC between communication ports.
  • LED indicators: 2 (communication and error status).
  • Enclosure: PC UL94 V-0, RAL 7035, IP20 protection rating.
  • Operating temperature: 0…+70 °C; humidity 5–95% RH (non-condensing).
  • Dimensions: 93 × 53 × 58 mm; weight 85 g.
  • Mounting: DIN rail or wall mount.

Warranty and certifications:
  • BTL (BACnet Testing Laboratories)
  • CE, RoHS compliant
  • Manufacturer warranty: 3 years

Contact Consteel Electronics expert for integration support →

Example of integration


Daikin to BACnet MS/TP Gateway – Model IN485MIT001A000 for HVAC Integration | Intesis by HMS

Daikin to BACnet MS/TP Gateway – Model IN485MIT001A000 for HVAC Integration | Intesis by HMS

General technical parameters
Protocol support BACnet MS/TP
Industrial grade
Casing Plastics
Operating temperature 0°C to 70°C
Certificates & standards CE, RoHS, BTL
Manufacturer's warranty 3 years
Mount DIN rail

Write a review

Note: HTML is not translated!
Bad Good
1

We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!

Do you have a question about a product? Write to us!

We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.