Midea Commercial & VRF systems to BACnet MSTP Interface - 1 unitThe INBACMID001I100 Midea-BACnet gateway allows fully bi-directional communication between Midea Commercial and VRF units and BACnet MSTP networks. The INBACMID001I100 gateway is wired directly to a Midea indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint, but the monitoring of errors, alarms and some int..
Industrial gate with the Panasonic ECOi and PACi system to the BACnet MSTP interface
Panasonic-BACnet gateway enables fully bidirectional communication between Panasonic ECOi and PACi and BACnet MSTP networks.
Features:
The BTL mark ensures full interoperability with BACnet devices
Only supports BACnet MS/TP
Configuration via built-in DIP switches
Quick and easy installation (connect and set DP-SW)
No external power required
Simultaneous ..
Toshiba VRF and Digital systems to BACnet MSTP Interface. The INBACTOS001R100 Toshiba-BACnet gateway allows fully bi-directional communication between Toshiba VRF and Digital Air Conditioner units and BACnet MSTP networks.The gateway is wired directly to the indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint, but the monitoring of errors, alarms and some internal var..
Bosch Commercial & VRF systems to Modbus RTU Interface - 1 unitThe INMBSACA001I000 Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks.Features:Modbus RTU (EIA485) slave deviceConfiguration from both onboard DIP-switches and Modbus RTUQuick and easy installation (plug and set the DP-SW)Simultaneous control of the AC unit by the IR remote controller and by Mod..
Midea VRF systems and commercial lines to Modbus Gateway for 1 indoor unit. The INMBSMID001I000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Midea VRF and commercial lines solutions from a Modbus installation.The gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units connected to the system. This allows not only the control and monitor..
LG VRF systems to Modbus Interface. IntesisBox LG-RC-MBS-1 (INMBSLGE001R000) allows monitoring and control, fully bi-directionally, all the functioning parameters of LG VRF Air Conditioners into Modbus RTU (RS-485) networks.The gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variable..
Mitsubishi Electric AC units to Modbus Interface. IntesisBox ME-AC-MBS-1 (INMBSMIT001I000) allows monitoring and control, fully bi-directionally, all the functioning parameters of Mitsubishi Electric Domestic and Mr.Slim Air Conditioners into Modbus RTU (RS-485) networks.The ME-AC-MBS-1 (INMBSMIT001I000) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temper..
Mitsubishi Heavy Industries FD and KX6 systems to Modbus Interface. IntesisBox MH-RC-MBS-1 (INMBSMHI001R000) allows monitoring and control, fully bi-directionally, all the functioning parameters of Mitsubishi Heavy Industries FD and KX6 (VRV) Air Conditioners into Modbus RTU (RS-485) networks.Features:Reduced dimensionsQuick and easy installationExternal power not requiredDirect connection to MODBUS RTU (RS-485) networks. Up to 63 MH-RC-MBS-1 dev..
Panasonic Etherea AC units to Modbus Interface. IntesisBox PA-AC-MBS-1 (INMBSPAN001I100) allows monitoring and control, fully bi-directionally, all the functioning parameters of Panasonic Etherea Air Conditioners into Modbus RTU (RS-485) networks.The PA-AC-MBS-1 (INMBSPAN001I100) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the mo..
Panasonic ECOi and PACi systems to Modbus Interface. IntesisBox PA-RC2-MBS-1 (INMBSPAN001R000) allows monitoring and control, fully bi-directionally, functioning parameters of PANASONIC ECOi and PACi Air Conditioners into Modbus RTU (RS-485) networks.The PA-RC2-MBS-1 (INMBSPAN001R000) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but t..
Modbus RTU (RS-485) Interface for Samsung air conditioners. IntesisBox SM-RC-MBS-1 (INMBSSAM001R000) allows monitoring and control, fully bi-directionally, all the functioning parameters of Samsung Commercial and VRF Air Conditioners into Modbus RTU (RS-485) networks.The SM-RC-MBS-1 (INMBSSAM001R000) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperatur..
Samsung NASA Air Conditioners to Modbus Interface. IntesisBox SM-RC2-MBS-1 (INMBSSAM001R100) allows monitoring and control, fully bi-directionally, all the functioning parameters of Samsung NASA Air Conditioner units into Modbus RTU (RS-485) networks.The SM-RC2-MBS-1 (INMBSSAM001R100) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but t..