Toshiba VRF and Digital systems to Modbus Interface. IntesisBox TO-RC-MBS-1 (INMBSTOS001R000) allows monitoring and control, fully bi-directionally, functioning parameters of Toshiba VRF and Digital Air Conditioners into Modbus RTU (RS-485) networks.The TO-RC-MBS-1 (INMBSTOS001R000) gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the..
Samsung NASA units to BACnet MSTP Interface - 1 unitThe INMBSSAM001R100 interfaces allow a complete and natural integration of Samsung NASA air conditioners into BACnet MS/TP (EIA-485 / RS-485) networks.Features:Reduced dimensions. 93 x 53 x 58 mm / 3.7” x 2.1” x 2.3”Quick and easy installationMountable on DIN rail, wall, or even inside the indoor unit of ACExternal power supply not requiredDirect connection to BACnet MS/TP (EIA-485 / RS-485) net..
Daikin VRV and Sky systems to Wi-Fi interface. IntesisBox DK-RC-WMP-1 INWMPDAI001R000 allows a complete and natural integration of Daikin air conditioners into IP based control systems. Compatible with SKY Air and VRV Air Conditioners commercialized by Daikin.The aim of this integration is to monitor and control your Daikin VRV air conditioning system, remotely, from your Control Center using any commercial SCADA or monitoring software that inclu..
Fujitsu RAC and VRF systems to Wi-Fi. IntesisBox FJ-RC-WMP-1 INWMPFGL001R000 allows a complete and natural integration of Fujitsu Air Conditioners into IP based control systems. Compatible with Domestic Air and VRF Air Conditioners commercialized by Fujitsu.The aim of this integration is to monitor and control your Fujitsu Air Conditioning system, remotely, from your Control Center using any commercial SCADA or monitoring software that includes t..
LG domestic and VRV AC units to Wi-Fi interface. IntesisBox LG-RC-WMP-1 (INWMPLGE001R000) interface allows a complete and natural integration of Mitsubishi Electric air conditioners into IP based control systems. Compatible with VRF line models commercialized by LG.The aim of this integration is to monitor and control your LG Air Conditioning system, remotely, from your Control Center using any commercial SCADA or monitoring software that include..
Mitsubishi Heavy Industries FD and KX6 systems to Wi-Fi Interface. IntesisBox MH-RC-WMP-1 (INWMPMHI001R000) interface allows a complete and natural integration of Mitsubishi Heavy Industries air conditioners into IP based control systems. Compatible with RAC Series, FD Series, KX6 and KXR6 (VRF) models commercialized by Mitsubishi Heavy Industries.The aim of this integration is to monitor and control your Mitsubishi Heavy Industries air condition..
Industrial CANopen to Modbus RTU master (RS232 or RS485) converter, housing type A (slim), DIN rail mount. HD67001 allows you to connect some Modbus RTU slaves with an existing CANopen network. Converter is easy to configure thanks to free SW67001 software.Configuration:Thanks to SW67001 software on your PC, you can:Define that the CANopen frame of the CANopen are reading from ModbusDefine that the CANopen frame of the CANopen are writing from Mo..
Industrial CANopen to Modbus RTU slave (RS232 or RS485) converter, housing type A (slim), DIN rail mount. HD67002 allows you to connect a CANopen network with a Modbus RTU Master (for example a PLC, HMI, etc.) in order to exchange the informations between the networks. Converter is easy to configure thanks to free SW67002 software.Configuration:Thanks to SW67002 software on your PC you can:Define that the SDO of the CANopen are accessible from Mo..
Industrial CAN 2.0 to Modbus RTU master (RS-232 or RS-485) industrial converter, housing type A (slim), DIN rail mount. HD67011 allows you to connect some Modbus Slaves with an existing CAN network. Converter is easy to configure thanks to free SW67011 software.Configuration:Thanks to SW67011 software on your PC, you can:Define which Modbus Registers are reading from CANbus frameDefine which Modbus Registers are writing from CANbus frameCharacte..
Industrial CAN 2.0 to Modbus RTU slave (RS232 or RS485) industrial converter, housing type A (slim), DIN rail mount. HD67012 allows you to connect a CAN network with a Modbus Master (for example a PLC, HMI, etc.) in order to exchange the informations between the networks. Converter is easy to configure thanks to free SW67012 software. Configuration:Thanks to SW67012 software on your PC, you can:Define that the CANbus frame of the CANbus are readi..
Industrial MBus Slave to Serial Converter, housing type B (wide), DIN rail mount. HD67018 allows to read/write M-Bus Slaves devices on RS485 (like Caleffi meters, etc.) with a Standard MBus Master (M-Bus physical layer). Converter is easy to install and configure thanks to free software SW67018.Configuration:Thanks to SW67018 software on your PC, you can:Define the parameters of M-Bus lineDefine the parameters of serial (RS232/RS485) lineUpdate t..
MBus to RS-232 - Converter (for Analog Modem connection, Master MBus: up to 40 slaves), housing type B (wide), DIN rail mount. This series allows to comunicate with the Slaves M‐bus remotely, using an Analog Modem or a GSM Modem. Moreover it is possible to connect directly to the device using a Null‐Modem serial cable. Converter is easy to configure thanks to free SW67023 software.Characteristics:European standard EN 1434Microprocessor controlCon..