MBus to Modbus converters for meter reading, up to 250 meters at once

M-Bus to Modbus converters and gateways

Industrial M-Bus to Modbus Converters

In this section of our shop, you will find a wide range of M-Bus to Modbus converters that allow seamless integration of M-Bus meters with Modbus-based control systems. These devices support both Modbus TCP (Ethernet) and Modbus RTU (RS-485/RS-232), enabling flexible communication with PLCs, building automation systems (BMS), HVAC controllers, SCADA systems, and energy management platforms. Whether you are integrating gas, water, electricity, or thermal energy meters — our converters offer stable, scalable and easy-to-deploy solutions for industrial environments.

What Makes Our M-Bus to Modbus Converters Stand Out?

Each converter in our lineup is designed for use in demanding industrial applications. Devices are mounted on standard DIN rails, built with EMC-resistant enclosures, and capable of operating in extreme temperatures ranging from -40°C to +85°C. Most models are housed in compact metal enclosures, making them ideal for installation in electrical cabinets, junction boxes, or remote field enclosures.

Our converters support communication with all M-Bus-compliant meters, including popular manufacturers such as Kamstrup, BMeters, Apator, Schrack, Astat and many others. They act as Modbus slaves, making the meter data directly accessible from any SCADA or controller using Modbus read commands.

Flexible Connectivity Options

The converters are equipped with the following communication ports:

  • M-Bus (master) – screw terminals for direct connection of up to 250 M-Bus meters
  • RS-485 / RS-232 – for Modbus RTU communication with serial devices
  • Ethernet (RJ45) – for Modbus TCP communication and web-based configuration

Depending on the model, the converters support 20, 40, 80, 160, or 250 M-Bus devices. The number of supported meters determines the power requirements of the device, with typical consumption ranging from 4W to 30W. All devices comply with M-Bus transmission standards, including max bus length of 350 meters (JYStY N*2*0.8mm cable), baud rates between 300 and 9600 bps, and bus voltage levels.

Reliable and Configurable M-Bus Integration

Each M-Bus to Modbus converter comes bundled with free configuration software. The included Scan & Decode tool allows you to scan the entire M-Bus network, automatically detect connected meters, and map meter variables to Modbus registers. It also supports mathematical transformations (e.g., multiplying/dividing values for scaling) and manual register mapping for custom integration.

For applications that require extending the length of the M-Bus or isolating separate meter groups, we also offer a full line of M-Bus repeaters and isolators. These devices ensure reliable operation even in large or complex meter networks.

Where Are These Converters Used?

M-Bus to Modbus gateways are commonly used in:

  • Smart building systems (heating, ventilation, air conditioning)
  • Energy management and billing systems
  • Remote meter reading (gas, water, heat, electricity)
  • Industrial automation and factory control networks
  • Public utilities and smart city infrastructure

Why Choose Our M-Bus to Modbus Solutions?

  • Industrial-grade reliability and DIN rail design
  • Up to 250 meters supported per converter
  • Support for both Modbus TCP and Modbus RTU
  • Free intuitive software for fast configuration
  • Proven compatibility with leading meter brands
  • Wide temperature range and high EMC resistance

Explore our full range of M-Bus to Modbus converters and choose the model that best suits your application. For project consultations, custom integration support or technical advice, contact our team — we’ll help you build a reliable and future-ready communication infrastructure.

INMBSMEB0200000 - M-Bus gateway to Modbus up to 500 points and 20 devices
3 year warranty Quantity discount 5-7 days
Brand: Intesis Model: INMBSMEB0200000
INMBSMEB0200000 – M-Bus to Modbus Gateway for 500 Points and 20 Devices.  The INMBSMEB0200000 gateway from Intesis is designed to enable bidirectional integration between M-Bus meters and Modbus-based systems such as BMS, SCADA or industrial PLCs. It supports up to 20 M-Bus devices and makes available up to 500 data points in the Modbus network, allowing precise and scalable metering integration for energy, water, gas and heat consumpti..
3,525.00 zł
INMBSMEB0600000 - M-Bus gateway to Modbus, 1500 points, 60 devices
3 year warranty Quantity discount 5-7 days
Brand: Intesis Model: INMBSMEB0600000
INMBSMEB0600000 – M-Bus to Modbus RTU/TCP Gateway for 60 Devices and 1500 Data Points.  The INMBSMEB0600000 IntesisBox gateway enables seamless bidirectional communication between M-Bus metering systems and any Modbus TCP or Modbus RTU master device such as BMS, SCADA or PLC. Supporting up to 60 M-Bus devices and 1500 Modbus data points, this gateway is ideal for large commercial and industrial automation environments where centralized ..
4,935.00 zł
INMBSMEB1200000 - M-Bus gateway to Modbus, 3000 points, for 120 meters
3 year warranty Quantity discount 5-7 days
Brand: Intesis Model: INMBSMEB1200000
INMBSMEB1200000 – M-Bus to Modbus RTU/TCP Gateway for 120 Devices and 3000 Data Points.  The INMBSMEB1200000 is a high-capacity industrial M-Bus to Modbus gateway developed by Intesis to facilitate bidirectional communication between up to 120 M-Bus devices and any Modbus RTU or Modbus TCP-based system such as BMS, SCADA or PLC. With support for up to 3000 data points, it provides an ideal solution for energy monitoring in large buildin..
6,815.00 zł