Fujitsu VRF systems to Modbus TCP-RTU - 16 unitsThe newer version of this device is IN775FGL00SO000The Fujitsu interface has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a BMS, SCADA, PLC or any other device working as a Modbus master. The Fujitsu interface has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a BMS, SCADA, PLC or any other device..
Hisense VRF systems to Modbus Gateway for 16 indoor units. The newer version of this device is IN770AIR00SO000The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Hisense VRF systems from a BMS, SCADA, PLC or any other device working as a Modbus Master.The gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units connected to the system. Thi..
Hisense VRF systems to Modbus Gateway, for 64 indoor units. The newer version of this device is IN770AIR00MO000The INMBSHIS064O000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Hisense VRF systems from a BMS, SCADA, PLC or any other device working as a Modbus Master.The gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units connected to..
Hitachi VRF systems to Modbus Gateway for 16 indoor units. The newer version of this device is IN770AIR00SO000The INMBSHIT016O000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Hitachi VRF systems from a BMS, SCADA, PLC or any other device working as a Modbus Master.The INMBSHIT016O000 gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor uni..
Hitachi VRF systems to Modbus Gateway for 64 indoor units. The newer version of this device is IN770AIR00MO000The INMBSHIT064O000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Hitachi VRF systems from a BMS, SCADA, PLC or any other device working as a Modbus Master.The INMBSHIT064O000 gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor uni..
Midea VRF systems and commercial lines to Modbus Gateway for 4 indoor units. The newer version of this device is IN770AIR00SO000The INMBSMID004I000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Midea VRF and commercial lines solutions from a Modbus installation.The INMBSMID004I000 gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units c..
Midea VRF systems and commercial lines to Modbus Gateway for 8 indoor units. The newer version of this device is IN770AIR00SO000The INMBSMID008I000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Midea VRF and commercial lines solutions from a Modbus installation.The INMBSMID008I000 gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units c..
Midea VRF systems and commercial lines to Modbus Gateway for 32 indoor units. The newer version of this device is IN770AIR00MO000The INMBSMID032I000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Midea VRF and commercial lines solutions from a Modbus installation.The INMBSMID032I000 gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units ..
Mitsubishi Electric Citiy Multi systems to Modbus Gateway. The newer version of this device is IN770AIR00SO000INMBSMIT050C000 Modbus Server - MITSUBISHI ELECTRIC AC (RAC, PAC, VRF) 50 Groups. City Multi with AG-150A, G-50A, GB-50A or GB-50ADA, AE-200, EW-50. The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Mitsubishi Electric City Multi systems from a BMS, SCADA, PLC or any other device working a..
Mitsubishi Electric Citiy Multi systems to Modbus Gateway. The newer version of this device is IN770AIR00MO000INMBSMIT100C000 Modbus Server - MITSUBISHI ELECTRIC AC (RAC, PAC, VRF) 100 Groups. City Multi with AG-150A, G-50A, GB-50A or GB-50ADA, AE-200, EW-50. The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Mitsubishi Electric City Multi systems from a BMS, SCADA, PLC or any other device working ..
Panasonic ECOi, ECOg and PACi systems to Modbus TCP/RTU Interface for 16 units. The newer version of this device is IN770AIR00SO000The INMBSPAN016O000 IntesisBox Gateway has been specially designed to allow bi-directional control and monitoring of Panasonic VRF systems through the CZ-CFUNC2 adaptor from a BMS, SCADA, PLC or any other device working as a Modbus Master.The INMBSPAN016O000 gateway is directly connected to the outdoor units communica..
Panasonic ECOi, ECOg and PACi systems to Modbus TCP/RTU Interface for 64 units.The newer version of this device is IN770AIR00MO000The INMBSPAN064O000 IntesisBox Gateway has been specially designed to allow bi-directional control and monitoring of Panasonic VRF systems through the CZ-CFUNC2 adaptor from a BMS, SCADA, PLC or any other device working as a Modbus Master.The INMBSPAN064O000 gateway is directly connected to the outdoor units communicat..