SCR-4-TD
5-10 days
Safety monitoring relay with combined Time Delay IDEM SCR-4-TD.
The SCR-4-TD Range of all purpose Safety Monitoring Relays combine time delayed and non time delayed contacts in a compact 22.5mm housing.
This permits dangerous components of a system to be switched off quickly and safely, whilst at the same time other circuits are still supplied with voltage for up to 30 seconds (adjustable on the SCR-4-TD by a potentiometer).
Features:
- Force guided safety output contacts - available in 3 variants
- Standards: EN60204-1, ISO13849-1, EN62061
- Single or Dual Channel input with LED indication of input status.
- Redundancy and cycle monitoring.
- Feedback loop for monitoring contacts or expansion modules.
- Short circuit and earth fault monitoring.
- 22.5mm Din Rail Mounting.
Specification:
Standards:
- EN60204-1
- ISO13849-1:
- Performance Level: e
- Category (ISO13849-1): Non Delayed: 4; Delayed: 3
- MTTFd: 73.36 years
- DC (average): 99% Delayed: 90%
- Proof Test Interval (Life): 10 years
- Safety Data Annual Usage: 261 days per year/16 hours per day; Test cycle 180 seconds/cycle; Low load AC1
- EN62061:
- SILCL: Non Delayed: 3
- Proof Test Interval (life): 20 years
- Hardware Fault Tolerance: 1
- DC (average): 99% Delayed: 90%
- PFHd: 4.22 x 10-8
- PFHd: Delayed: 8.84 x 10-8
Safety Classification and Reliability Data:
- Monitored Safety Inputs Circuits: 2NC or 1NC
- Safety Switching Outputs: 4NC
- Delayed Time: 1-30 seconds continuously adjustable
- Operating Voltage: 24Vac/dc
- Supply Deviation: +/-10%
- Control Voltage at S11: 24Vdc
- Control Current S11 to S14: 190mA approx.
- Monitored Reset Circuit Loop: Auto or Monitored Manual Reset
- Maximum Line Conductor Cross Section: 2.5 sq mm
- Maximum Length of Control Line: 1000m with 0.75 sq mm
- Contact Material: AgNi
- Indication - Green:
- LED1 internal relay K1 energised
- LED2 internal relay K2 energised
- LED1 and LED2 OSSD closed
- Contact Service Life: Mechanical 1x107; Electrical 1x105
- Safety Contact Breaking Capacity:
- AC: 250V, 1500VA, 6A, ohmic; 230V, 4A for AC15
- DC: 24V, 30W, 1.25A, ohmic; 24V, 30W, 2.0A for DC-13
- External Fuse Protection - Safety Outputs: 4A slow blow or 6A quick blow
- Minimum Voltage and Current: 24V, 20mA dc
- Response Time on Output Opening: 90ms
- Rated Insulation Voltage: 250V
- Protection: IP20
- Rated Impulse Withstand Voltage: 4kV
- Operating Temperature: -15°C ~ 40°C
- Mounting: 22.5mm DIN rail
- Weight: 250g approx.
Warranty: 36 months
Ordering Information:
- SCR-4-TD-1 180005 - Terminal type: Standard Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 3NC; Delayed output contacts: 1NC
- SCR-4-TD-1 180006 - Terminal type: Standard Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 2NC; Delayed output contacts: 2NC
- SCR-4-TD-1 180007 - Terminal type: Standard Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 1NC; Delayed output contacts: 3NC
- SCR-4-TD-1 180005-P - Terminal type: Pluggable Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 3NC; Delayed output contacts: 1NC
- SCR-4-TD-1 180006-P - Terminal type: Pluggable Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 2NC; Delayed output contacts: 2NC
- SCR-4-TD-1 180007-P - Terminal type: Pluggable Screw Terminals; Supply voltage: 24VAC/VDC; Switch input circuits: 2NC; Instant output contacts: 1NC; Delayed output contacts: 3NC
Industrial grade | |
IP rating | IP20 |
Operating temperature | -15°C to 40°C |
Input voltage | 24VAC, 24VDC |
Manufacturer's warranty | 36 months |
Mount | DIN rail |