HD67504 Industrial CANopen to Modbus TCP Master converter with slim housing

CANopen to Modbus TCP Master Converter – model HD67504 | ADFweb
2 year warranty Quantity discount 3-4 days
HD67504 Industrial CANopen to Modbus TCP Master converter with slim housing
  • Stock: 3-4 days
  • Brand: ADF Web
  • Model: HD67504-A1
1,701.40 zł
3 pieces or more 1,616.33 zł
10 pieces or more 1,531.26 zł
26 pieces or more 1,446.19 zł
51 pieces or more 1,276.05 zł

Industrial CANopen to Modbus TCP master converter, housing type A (slim), DIN rail mount.

HD67504 allows to communicate Modbus TCP slave with CANopen network. Converter is easy to install and configure thanks to free SW67504 software. It provides a reliable and cost-effective way to integrate CANopen devices with Modbus TCP systems commonly used in industrial automation. By using this converter, engineers can easily connect controllers, sensors, and field devices across different protocols without complex programming. Its compact slim housing (type A) makes it ideal for installations where limited space on DIN rails is available. The device is particularly useful in applications such as building automation, production lines, and energy monitoring, where interoperability between systems is essential. The simplicity of setup allows both experienced integrators and beginners to quickly put the device into operation. Moreover, thanks to the robust design, the converter ensures stable performance in demanding industrial environments with wide temperature ranges.

Configuration:

Thanks to the SW67504 software on your PC you can:
  • Define the parameters for the CANopen bus
  • Define the parameters for the Modbus TCP line
  • Define CANopen frames with which it is possible to read/write Modbus data
  • Update the device
The configuration tool offers a user-friendly graphical interface that guides you through the setup process. Defining CANopen frames makes it possible to map Modbus registers in a flexible way, tailored to the needs of each installation. Engineers can monitor the communication status in real time, which simplifies commissioning and troubleshooting. Firmware updates via the same software extend the product life cycle and allow adaptation to new requirements. With these tools, integration of Modbus TCP devices into CANopen systems becomes straightforward and efficient. Even complex automation projects can be handled without specialized programming knowledge. This reduces installation time, minimizes errors, and provides a more robust overall system performance.

Characteristics:

  • Electrical isolation between Ethernet – CAN, Power Supply – Ethernet, Power Supply – CAN
  • Bi-directional information exchange between CANopen and Modbus TCP
  • Mountable on 35 mm DIN rail
The presence of full galvanic isolation between all main interfaces increases safety and prevents damage caused by ground loops or electrical noise. Bidirectional communication ensures that both Modbus TCP and CANopen devices can exchange commands and data seamlessly. This is especially important in automation systems where monitoring and control must occur simultaneously. The slim DIN rail housing makes installation simple, even in dense control cabinets. Combined with its light weight and small dimensions, the HD67504 fits perfectly in compact automation systems. The converter has been designed for long-term use, with stable operation even under intensive industrial workloads. It is a durable and dependable solution for companies seeking to connect two widely used industrial communication standards.

Specifications:

  • Ports: 1x CAN; 1x Ethernet
  • CAN 2.0 connector: Terminal block
  • Ethernet connector: RJ45
  • Data Rates CANopen: From 10K to 1Mbps
  • Data Rates Modbus: 10/100 MHz Autosensing
  • Power supply: 8...19VAC; 8...35VDC
  • Operating temperature: -40°C/+85°C (-40°F/+185°F)
  • Dimensions: 120 mm x 23 mm x 107 mm (DxWxH)
  • Weight: 200g approx
  • Mechanical fixing: DIN Rail mount
  • ORDER CODE: HD67504-A1
The wide range of supported CANopen data rates (10K to 1Mbps) allows flexible integration with both legacy and modern CAN networks. Autosensing Ethernet ensures automatic adaptation to the connected network speed without manual configuration. Its wide input power supply range supports various installation environments and simplifies system design. The operating temperature range of -40°C to +85°C makes it suitable for both indoor and outdoor applications. Compact size combined with robust construction guarantees reliability in harsh industrial conditions. All technical features are optimized to deliver performance, durability, and interoperability.

Configurator – Software SW67504 FREE DOWNLOAD

Manufacturer's warranty: 24 months

CANopen to Modbus TCP Master Converter – model HD67504 | ADFweb

General technical parameters
Ethernet 1x 10/100BaseT(X)
CAN ports 1x CAN
Protocol support CANopen, Modbus TCP
Industrial grade
Operating temperature -40°C to 85°C
Input voltage 8~19VAC, 8~35VDC
Manufacturer's warranty 24 months
Mount DIN rail

Write a review

Note: HTML is not translated!
Bad Good
1

We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!

Tags: hd67504-a1 , can adf , web

Do you have a question about a product? Write to us!

We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.