5-10 days
Magnetic Non Contact IDEM IDEMAG CPR.
Magnetic Actuation - Power Series. Medium Duty Version 1A or Heavy Duty Version 230VAC/24VDC 2A. Switching tolerance up to 12mm.
Features:
- Specified to 80°C but designed to work up to 100°C.
- Will operate with most Safety Relays.
- Can be high pressure hosed at high temperature, rated IP69K.
- Slim fitting suitable for all industry applications.
- Easy to install within narrow frame structures.
- Operates from two sides for ease of application.
- Wide sensing at 12mm and high tolerance to misalignment.
- Quick Connect version available.
Specifications:
Standards:
- ISO14119
- EN60947-5-1
- EN60204-1
- ISO13849-1
- EN62061
- UL508
Safety Classification and Reliability Data:
- Mechanical Reliability B10d: 3.3 x 106 operations at 100mA load
- ISO13849-1: Up to PLe depending upon system architecture
- EN62061: Up to SIL3 depending upon system architecture
- Safety Data – Annual Usage: 8 cycles per hour/24 hours per day/365 days
- PFHd: 2.52 x 10-8
- Proof Test Interval (Life): 47 years
- MTTFd: 470 years
- Heavy Duty:
- Safety Channel 1 NC: Voltage Free: 250Vac 2A Max. Rating
- Safety Channel 2 NC: Voltage Free: 250Vac 2A Max. Rating
- Safety Channel 3 NO: Voltage Free: 24Vdc 0.2A Max. Rating
- Fuse: Internal 2.0A (F); External 1.6A (F) (User)
- Medium Duty:
- Safety Channel 1 NC: Voltage Free: 250Vac 1A Max. Rating
- Safety Channel 2 NC: Voltage Free: 250Vac 1A Max. Rating
- Safety Channel 3 NO: Voltage Free: 24Vdc 0.2A Max. Rating
- Fuse: Internal 1.0A (F); External 0.8A (F) (User)
- Contact Release Time: <2ms
- Initial Contact Resistance: <500 milliohm
- Minimum Switched Current: 10Vdc 1mA
- Dielectric Withstand: 250Vac
- Insulation Resistance: 100 Mohms
- Recommended Setting Gap: 5mm
- Switching Distance: Sao 10mm Close
- Switching Distance (Target to Target): Sar 22mm Open
- Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
- Switching Frequency: 1.0Hz maximum
- Approach Speed: 200mm/min to 1000mm/sec
- Body Material: UL approved polyester
- Operating Temperature: -25°C ~ 80°C
- Enclosure Protection: IP67 (NEMA 6); IP69K (NEMA PW12)
- Shock Resistance: IEC68-2-27; 11ms; 30g
- Vibration Resistance: IEC 68-2-6; 10-55Hz; 1mm
- Cable Type: PVC 6 core 6mm OD; Conductors 0.25mm2
- Mounting Bolts: 2xM4 Tightening torque 1.0Nm
- Mounting Position: Any
Warranty: 36 months
Ordering Information:
- Idemag CPR 113001 - Cable Length: 2M; Circuits: 2NC; NC Duty: Medium 1A
- Idemag CPR 113002 - Cable Length: 5M; Circuits: 2NC; NC Duty: Medium 1A
- Idemag CPR 113003 - Cable Length: 10M; Circuits: 2NC; NC Duty: Medium 1A
- Idemag CPR 113004 - Cable Length: QC-M12; Circuits: 2NC; NC Duty: Medium 1A
- Idemag CPR 113005 - Cable Length: 2M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Idemag CPR 113006 - Cable Length: 5M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Idemag CPR 113007 - Cable Length: 10M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Idemag CPR 113008 - Cable Length: QC-M12; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Idemag CPR 113009 - Cable Length: 2M; Circuits: 1NC; NC Duty: Heavy 2A
- Idemag CPR 113010 - Cable Length: 5M; Circuits: 1NC; NC Duty: Heavy 2A
- Idemag CPR 113011 - Cable Length: 10M; Circuits: 1NC; NC Duty: Heavy 2A
- Idemag CPR 113012 - Cable Length: QC-M12; Circuits: 1NC; NC Duty: Heavy 2A
- Idemag CPR 113013 - Cable Length: 2M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Idemag CPR 113014 - Cable Length: 5M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Idemag CPR 113015 - Cable Length: 10M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Idemag CPR 113016 - Cable Length: QC-M12; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
Industrial grade | |
Casing | Plastic |
IP rating | IP67, IP69K |
Operating temperature | -25°C to 80°C |
Input voltage | 230VAC, 24VDC |
Manufacturer's warranty | 36 months |
1
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!