Menu
Your Cart

HD67611-A1 Industrial PROFINET to Modbus TCP converter with DIN rail mount and triple isolation

Industrial PROFINET to Modbus TCP converter – model HD67611-A1 | ADFweb
2 year warranty Quantity discount 3-4 days
HD67611-A1 Industrial PROFINET to Modbus TCP converter with DIN rail mount and triple isolation
  • Stock: 3-4 days
  • Brand: ADF Web
  • Model: HD67611-A1
2,063.30 zł
3 pieces or more 1,960.14 zł
10 pieces or more 1,856.97 zł
26 pieces or more 1,753.81 zł
51 pieces or more 1,547.48 zł

Industrial PROFINET to Modbus TCP master converter, housing type A (slim), DIN rail mount.

The HD67611-A1 converter is a reliable industrial solution that enables seamless integration between PROFINET networks (e.g. SIEMENS PLC) and Modbus TCP Slave devices. It supports bi-directional communication, allowing for real-time data exchange between automation systems and Modbus-based field devices. The unit is especially useful in applications that require stable interoperability between industrial Ethernet and Modbus TCP/IP controllers. Thanks to its compact slim-type housing (Type A) and DIN rail mounting, the device is easy to install even in densely packed electrical cabinets. It is a robust tool for system integrators, offering configuration flexibility, fast commissioning and long-term durability. With support for up to 1440 bytes of data in each direction and advanced isolation mechanisms, the HD67611 ensures data integrity and EMC resilience. The converter includes dual Ethernet ports (RJ45, 10/100Base-T), allowing easy connection and fast communication. With the provided SW67611 configuration software, setting up data mappings and protocol parameters is quick and intuitive. This makes the device ideal for projects involving building automation, process control or machine integration using Modbus TCP and PROFINET.

Industrial PROFINET to Modbus TCP converter – model HD67611-A1 | ADFweb

Configuration:

Using the free SW67611 software, users can easily configure both PROFINET and Modbus TCP parameters from a Windows PC. The tool enables the creation of detailed mapping schemes and simplifies integration with existing PROFINET masters.

  • Set PROFINET line parameters including GSDML import/export
  • Configure Modbus TCP parameters like IP address, port, device IDs
  • Define Modbus registers to be read and mapped into the PROFINET memory array
  • Define write registers from PROFINET to control Modbus TCP devices
  • Generate XML/GSDML files to import into the PROFINET master configuration
  • Update firmware and load final settings to the converter via Ethernet

Characteristics:

  • DIN rail mountable – 35 mm EN standard
  • Up to 1440 bytes for reading and 1440 bytes for writing
  • Bidirectional communication between Modbus TCP and PROFINET
  • Triple galvanic isolation between Power ↔ Ethernet, Ethernet ↔ Modbus, Power ↔ Modbus
  • Fast and stable data transmission with 100 Mbit/s Ethernet
  • Supports Modbus TCP slaves including energy meters, I/O modules, drives

Specifications:

  • Ethernet ports: 2 × RJ45
  • Supported speed: 10/100Base-T, autosensing
  • Power supply: 8...24VAC or 12...35VDC
  • Operating temperature: -40°C to +85°C (-40°F to +185°F)
  • Dimensions: 71 × 60 × 95 mm (Depth × Width × Height)
  • Weight: Approx. 200g
  • Mounting: DIN rail 35 mm (EN 60715)
  • Configuration software: SW67611 (included)
  • Order code: HD67611-A1

Configurator – Software SW67611 FREE DOWNLOAD

General technical parameters
Ethernet 2x 10/100BaseT(X)
Protocol support PROFINET, Modbus TCP
Industrial grade
Operating temperature -40°C to 85°C
Input voltage 8~24VAC, 12~35VDC
Manufacturer's warranty 24 months
Mount DIN rail

Write a review

Note: HTML is not translated!
Bad Good
1

We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!

Do you have a question about a product? Write to us!

We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.