Industrial Isolated RS-232 to RS-422/485 Converter. Most industrial computer systems provide standard RS-232 serial ports. Though widely accepted, RS-232 has limited transmission speed, range, and networking capabilities. The RS-422 and RS-485 standards overcome these limitations by using differential voltage lines for data and control signals, which transparently converts RS-232 signals into isolated RS-422 or RS-485 signal with no need to chang..
16-channel Open Collector Isolated Digital Output Module. I-87057PW offers 16 channels for digital output, each of which features Photo-couple isolation. I-87057PW supports sink type output with shortcircuits protection. There are options for power-on value and safe value for your consideration. I-87057PW has 16 LED indicators for DO channel status. 4 kV ESD protection, 3750 VDC intra-module isolation are standard.Features:Support Digital Outputs..
8-channel Isolated Digital Input Module using the DCON and Modbus Protocols. The I-7052 offers 6 fully independent channels and 2 common ground channels for digital input. The diffential inputs feature channel-to-isolation. In addition, you can choose either sink- or source-type input via wire connections. All channels are able to be used as 16-bit has 8 LED indicators for DI channel status monitoring. 4 kV ESD protection and 5000 Vrms intra-modu..
Tiny Ethernet module with 2 Digital Inputs (Dry Contact) and 2 Form A PhotoMos relay. Providing various digital I/O functions, the tET/tPET series is an IP-based Ethernet I/O monitoring and control module. The module can be remotely controlled through a 10/100 M Ethernet network by using Modbus TCP protocol. Modbus has become a de facto standard communications protocol in industry, and is now the most commonly available means of connecting indust..
Tiny Ethernet module with PoE, 2 Digital Inputs (Wet Contact) and 2 Form A Power Relays.Providing various digital I/O functions, the tET/tPET series is an IP-based Ethernet I/O monitoring and control module. The module can be remotely controlled through a 10/100 M Ethernet network by using Modbus TCP protocol. Modbus has become a de facto standard communications protocol in industry, and is now the most commonly available means of connecting indu..
4-channel Isolated Digital Input and 4-channel Relay Output Module using the DCON Protocol with LED Display. The 7060 series provides 4 digital input channels, 2 Form A and 2 Form C signal relay output channels, while the M-7060P provides 4 digital input channels, 2 Form A and 2 Form C power relay output channels. All digital input channels can be used as 16-bit counters. In addition, the digital input channels can be selected either as sink- or ..
8-channel Isolated Digital Input and 3-channel Relay Output Module using the DCON Protocol with LED Display. The I-7063 module provides 8 digital input channels and 3 Form A relay output channels, and the 7065 series provides 4 digital input channels and 5 Form A relay output channels. All digital input channels can be used as 16-bit counters. In addition, the digital input channels can be selected either as sink- or source-type via wire connecti..
Industrial isolated RS-485 repeater, I-7510 by ICPDAS. Repeaters for RS-485 buses such as the I-7510 are used to extend the network range and increase the number of nodes that can be connected to a single bus. With repeaters, the limitations of a standard RS-485 bus, such as maximum cable length and number of devices, can be overcome. Features of RS-485 repeaters:Range extension: They amplify the data signal, allowing transmission over longe..
Industrial Unmanaged 5-port Ethernet Switch. The NS-205/NS-205A/NS-105A has 5 Ethernet Switching ports that support 10/100 Base-TX, with a 10/100M autonegotiation feature and auto MDI/MDI-X function. It can connect 5 workstations and automatically switches the transmission speed (10 Mbps or 100 Mbps) for corresponding connections. The flow control mechanism is also negotiated. There is activity/link/data rate LEDs for each port to aid trouble-sho..
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-232 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then ..
14-channel Isolated Digital Input Module with DCON Protocol. The I-7041 and I-7041P provide 14 channels for digital input, each of which features photocouple isolation. In addition, either sink- or source-type digital input can be selected via wire connections, and all channels are able to be used as 16-bit counters. The I-7041D and I-7041PD include 14 LED indicators that can be used for DI channel status monitoring. 4 kV ESD protection and 3750 ..
7-channel Non-isolated Digital Input and 8-channel Non-isolated Digital Output Module using the DCON Protocol with LED Display. The I-7050 series of modules offers channels for digital input and 8 channels for digital output, each of which are non-isolated. The I-7050 supports sink-type output using an NPN open collector, and source-type input. All input channels are able to be used as 16-bit counters. There are also options to enable both power-..