Industrial Isolated Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-232 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy seri..
14-channel Isolated Digital Input Module with DCON Protocol with LED Display. The I-7041 and I-7041P provide 14 channels for digital input, each of which features photocouple isolation. In addition, either sink- or source-type digital input can be selected via wire connections, and all channels are ..
8-channel Isolated Digital Input and 8-channel Isolated Digital Output Module using the DCON Protocol. The I-87054W module offers 8 isolated Digital Input channels and 8 isolated Digital Output channels. Either sink- or source-type Digital Input can be selected via the wire connections, and all Digi..
8-channel Form A Signal Relay Output Module. The M-7064 module provides 8 Form A signal relay output channels. The M-7064D module include 8 LED indicators that can be used to monitor the status of the relay output, and options are provided that allow power-on and safe Relay Output values to be confi..
4-channel Form A Signal Relay Output and 4-channel Form C Signal Relay Output Module. The M-7068 provides 4 Form A signal relay output channels and 4 Form C signal relay output channels, while the M-7069 provides 4 Form A power relay output channels and 4 Form C power relay output channels. Both inc..
Industrial isolated RS-422/485 Repeater/Converter. The I-7510/I-7510A provides 2-way optical isolation between one piece of RS-422/RS-485 equipment and the rest of the system. It can also be used as a repeater to extend the transmission of an existing network. Additionally, an RS-485 system can be e..
Industrial USB to Isolated RS-232/422/485 Converter. The I-7561 is a cost-effective module for transferring serial data via USB. It allows you to connect your serial devices to systems that use a USB interface. Connecting the I-7561 to a PC, you get one RS-232/422/485 port. Like the I-7520A, the I-7..
Industrial Isolated RS-485 Repeater. The tM-7510U repeater simply amplifies, or boosts, existing RS-485 signals to enable them to cover longer distances. It extends the communication distance by 4000 ft. (1200 m) or increases the maximum number of bus nodes. The module provides 2500 VDC of isolation..
4-port Industrial USB 2.0 Hub. The USB-2560 allows you to add multiple high performance USB 2.0 peripheral devices to your computer (Or XP-8000 series). It supports the USB 2.0 high-speed mode that can achieve 480 Mbps data transmitting rate.The USB-2560 only supports self-powered mode (drawing powe..
8-channel Isolated AC/DC Digital Input Module using the DCON Protocol with LED Display. The I-7058/I-7059 module offers 8 differential channels for AC/DC Digital Input, each of which features channel-to-channel Photocouple isolation. All DI channels are also able to be used as 16-bit counters. The I..
4-channel Isolated Digital Input and 4-channel Relay Output Module using the DCON Protocol. The 7060 series provides 4 digital input channels, 2 Form A and 2 Form C signal relay output channels, while the M-7060P provides 4 digital input channels, 2 Form A and 2 Form C power relay output channels. A..
14-channel Isolated Digital Input Module with DCON and Modbus Protocols.The I-7041 and I-7041P provide 14 channels for digital input, each of which features photocouple isolation. In addition, either sink- or source-type digital input can be selected via wire connections, and all channels are able t..
14-channel Isolated Digital Input Module with DCON and Modbus Protocols and LED Display.The I-7041 and I-7041P provide 14 channels for digital input, each of which features photocouple isolation. In addition, either sink- or source-type digital input can be selected via wire connections, and all cha..
7-channel Non-isolated Digital Input and 8-channel Non-isolated Digital Output Module using the DCON and Modbus Protocols with LED Display. The I-7050 series of modules offers channels for digital input and 8 channels for digital output, each of which are non-isolated. The I-7050 supports sink-type ..
Tiny Ethernet module with PoE and 6-channel Digital Inputs (Dry Contact).Providing various digital I/O functions, the tET/tPET series is an IP-based Ethernet I/O monitoring and control module. The module can be remotely controlled through a 10/100 M Ethernet network by using Modbus TCP protocol. Mod..
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 3 RS-232 Ports. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial commu..
8-channel Isolated AC/DC Digital Input Module using the DCON Protocol with LED Display. The I-7058/I-7059 module offers 8 differential channels for AC/DC Digital Input, each of which features channel-to-channel Photocouple isolation. All DI channels are also able to be used as 16-bit counters. The I..
16-channel 68-150 VDC Isolated Digital Input Module with 16-bit Counters. The I-87053W-A5 and I-87053W-E5 provide 16 channels for high voltage digital input, each of which features photocouple isolation. The input voltage level can be as high as 150 VDC. In addition, either sink- or source type digi..
16-channel 68-150 VDC Isolated Digital Input Module with 16-bit Counters. The I-87053W-A5 and I-87053W-E5 provide 16 channels for high voltage digital input, each of which features photocouple isolation. The input voltage level can be as high as 150 VDC. In addition, either sink- or source type digi..
15-channel Isolated Digital Input Module using the DCON or Modbus Protocol with LED Display. The M-7046 is a 15-channel Digital Input module. Each channel features optoisolation and can be used as a 16-bit counter. In addition, the Digital Input type can be selected as either sink or source via wire..