MOD-16I-M



2-3 days



By the same series
Brand: Aspar
Model: MOD-16I
Industrial expansion module, 16 digital inputs on Modbus RTU, with RS485 interface. The module communicates with all commercially available PLCs, devi..
564.00 zł
Brand: Aspar
Model: MOD-16RO
Industrial expansion module, 16 relay outputs on Modbus RTU, with RS485 interface. Features:OUTPUT: 16 relay outputsINPUT: RS485 - Modbus Slave (ASCII..
606.30 zł
Brand: ICPDAS
Model: M-7080 CR
2-channel Counter/Frequency Input Module with DCON and Modbus Protocol.The I-7080 offers 2 high speed counter or frequency input channels and 2 digita..
799.00 zł
Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports
If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.
- Device User Manual
- CE Declaration of Conformity (EU Declaration of Conformity)
- Mechanical Drawings – CAD (STEP/DWG) or high-quality PDF
- Additional Certificates (if available for the model)
- Test Reports (if available for the model)
Industrial expansion module with FRAM memory, 16 digital inputs to Modbus RTU, with RS485 interface.
Features:
- INPUT: 16 digital inputs with memory
- OUTPUT: RS485 - Modbus Slave (ASCII, RTU)
- FRAM - non-volatile random-access memory
- Mounting on a DIN rail
- 16 configurable 32-bit counters
- Counter modes: pulse counter, timer, encoder
- Inputs PNP or NPN, depending on the connection
- Galvanic isolation of inputs
- Comfortable connectors for cables (up to 2.5 mm2)
- Configuration: free software
- 2 years warranty
- Made in Poland
The MOD16I-M is an innovative device that provides a simple and inexpensive extension of the input lines of popular PLCs.
The module communicates with all commercially available PLCs, devices that support the popular MODBUS MASTER protocol.
The module has 16 digital inputs with counter option. Inputs are isolated from logic using optocouplers. Each channel can be individually configured in one of several modes (counting pulses, counting time, encoder).
The module has a fast non-volatile memory type FRAM that stores the values of the counters and the values of the counters captured. Thanks to this, even after power failure, these values are stored and can be used after the power is restored.
This module is connected to the RS485 bus via two wire twisted pair. Communication is made using the MODBUS RTU or MODBUS ASCII protocol. The use of a 32-bit ARM core processor provides fast data processing and fast communication. The transmission speed is configurable from 2400 to 115200.
The module is designed for mounting on DIN rail according to DIN EN 5002.
The module is equipped with a set of LEDs used to indicate the status of inputs useful for diagnostic purposes and to help identify errors.
Configuration of the module is done via USB with a dedicated computer program. It is also possible to change parameters using the MODBUS protocol.
SLIM modules can be easily connected to each other via the Quick Connector. Just supply the module and RS485 power to the first module. With the MOD-QC tape, both values will be passed to the next modules.
Available accessories:
- Connection tape: MOD-QC
- Programming cable: mini USB
| General technical parameters | |
| Serial port | 1x RS-485 |
| I/O | 16x digital input |
| Protocol support | Modbus RTU, Modbus ASCII |
| Industrial grade | |
| Optoisolation | 1500V |
| Operating temperature | -10°C to 50°C |
| Input voltage | 12~24VDC |
| Manufacturer's warranty | 2 years |
| Mount | DIN rail |
1