A proven choice for industrial installations.
Ask for compatibility and model selection.
Register and get cheaper offers today.

Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports

If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.

  • Device User Manual
  • CE Declaration of Conformity (EU Declaration of Conformity)
  • Mechanical DrawingsCAD (STEP/DWG) or high-quality PDF
  • Additional Certificates (if available for the model)
  • Test Reports (if available for the model)
Request a package: User manual, CE declaration, CAD, PDF, certificates, test reports

Power cables with aluminum wires with XLPE insulation and PE coating.

Construction:

  • Veins: Multi-round round class 2 according to EN 60228
  • Screen on the veins: Semi-conductive polyethylene
  • Isolation: Cross-linked polyethylene
  • Screen on insulation: Semi-conductive polyethylene
  • Sealing: Thrust
  • Metallic screen: Cu wires / Cu band
  • Coating: Polyethylene
  • Coating color: UV-resistant red

Characteristic:

  • Maximum core temperature during cable operation: + 90 °C
  • Minimum ambient temperature for permanently laid cables: -30 °C
  • The minimum ambient temperature for cable laying: -20 °C
  • Maximum core temperature during short circuit: + 250 °C
  • Maximum pull force for the work piece: 30 x S (S = cross-section Al in mm²) [N]
  • Min. Bending radius: 15d (d = cable diameter)
  • Test voltage: 3.5 * Uo / 5 min
  • Application: For the transmission of electricity. They can be laid in the ground, indoors and outdoors.
  • Packing: 500 or 1000 m on the drum. It is possible to offer other lengths and types of packaging

Compliant with: PN-HD-620 S2: 10C / DIN VDE 0276-620


Cable parameters
CoreAluminium
InsulationXLPE
Outer coatingPolyethylene, Polyvinyl chloride (PVC)
Maximum allowable tensile stresses1.5 kN, 2.1 kN, 2.85 kN, 3.6 kN, 4.5 kN, 5.55 kN, 7.2 kN, 9.0 kN, 12.0 kN, 15.0 kN, 18.9 kN, 24.0 kN, 30.0 kN
Diameter of the working conductor [mm]8.25, 9.5, 11.3, 12.5, 14.2, 15.8, 17.9, 20.0, 22.9, 25.7, 29.3, 33.0, 38.0
Outer diameter [mm]28.1, 29.4, 31.2, 32.4, 34.1, 35.7, 37.8, 39.9, 42.8, 46.3, 50.3, 54.6, 60.0, 30.1, 31.4, 33.2, 34.4, 36.1, 37.7, 39.8, 41.9, 44.8, 48.3, 52.3, 56.8, 62.0
Cable weight [kg/km]720, 890, 1100, 1330, 1440, 1580, 1780, 1990, 2300, 2710, 3190, 3780, 4510, 790, 970, 1180, 1420, 1540, 1680, 1890, 2110, 2420, 2840, 3330, 3950, 4680