Menu
Your Cart

M-Bus to Modbus converters for meter reading

M-Bus to Modbus converters and gateways

Industrial M-Bus to Modbus converters

In this section of our shop you will find converters from M-Bus to Modbus TCP or RTU interface. M-Bus is the standard used for reading various types of consumer meters such as gas meters, water meters, electricity meters, heat meters and others. The converters allow the integration of M-Bus devices into Modbus TCP or RTU (e.g. control systems, air conditioning, heating, BMS).

Learn more about our M-Bus to Modbus converters

Each M-Bus to Modbus converter in our range features easy DIN rail mounting, immunity to electromagnetic interference and the ability to be installed in outdoor boxes and environments with a wide operating temperature range from -40°C to 85°C. Our M-Bus to Modbus converters are versatile devices suitable for use in diverse industrial environments.

Converters support all meters communicating in the M-Bus protocol, including manufacturers such as Kamstrup, Astat, Schrack, BMeters, Apator and many others. Depending on the model, the converter can read 20, 40, 80, 160 or 250 meters on a single bus. The devices have M-Bus connectors for connecting meters (screw connector), Ethernet for programming and communication over Modbus TCP and RS-485 and RS-232 for communication over Modbus RTU (screw connectors). The converters for reading the status of the M-Bus meters on the Modbus protocol side always operate as Modbus slaves.

The maximum power consumption of the converters depends on the number of meters connected to it, with 20 meters it is 4W, with 40 meters 5W, with 80 meters 8W, with 160 meters 14W and with 250 meters it is 30W. The M-Bus, as standard, allows meters to be connected on a bus with a maximum length of 350m with a JYStY N*2*0.8mm cable with a resistance of 29Ω and a baud rate between 300b/s and 9600b/s. To increase the length of the bus, we can lower the baud rate or reduce the number of counters plugged into the bus so that the bus voltage does not drop below 12V at any time. If achieving this is not possible, we suggest using M-Bus converters.

Thanks to the free software included with each device, the converters are very easy to configure. The included Scan&Decode tool allows you to very quickly scan the entire M-Bus and assign variables from all counters to subsequent Modbus registers. The configuration tool also allows mathematical operations on the readings (multiplication and division) and manual configuration of the readings of selected counter values.

Select the M-Bus to Modbus converter you are interested in and refer to the detailed technical description.

HD67029-B2-485-160
3-4 days
Brand: ADF Web Model: HD67029-B2-485-160
Industrial MBus to Modbus RTU converter, master MBus up to 160 slaves, modbus slave Port: RS485. The converter for communication with meters uses the MBus, RS-485 connector is used for Modbus RTU communication. The HD67029M-485-160 converter can read up to 160 MBus receivers of any type (eg water meters, gas meters, energy meters). Converter is easy to configure thanks to free SW67029 software.New converter functionality - automatic scan of MBus ..
2 540,67 zł
HD67044-B2-160 HD67044-B2-160
3-4 days
Brand: ADF Web Model: HD67044-B2-160
Industrial MBus to Modbus TCP converter, master MBus up to 160 slaves, modbus slave port: Ethernet, housing type B (wide), DIN rail mount. The converter for communication with meters uses the MBus, Ethernet connector is used for Modbus TCP communication. The HD67044-B2-160 converter can read up to 160 MBus receivers of any type (eg water meters, gas meters, energy meters). Converter is easy to install and configure thanks to free SW67044 software..
2 646,73 zł
IBOX-MBS-MBUS IBOX-MBS-MBUS
5-7 days
Brand: Intesis Model: IBOX-MBS-MBUS
M-Bus to Modbus Gateway. The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of M-Bus Meters from a Modbus BMS, SCADA, PLC or any other device working as a Modbus Master.The aim of this integration is to make available signals and resources of meters connected to M-Bus, from a Modbus master device or system. For this IntesisBox Modbus Server - M-Bus gateway works, ..
2 670,83 zł
INMBSMEB0100000
5-7 days
Brand: Intesis Model: INMBSMEB0100000
M-Bus to Modbus Gateway for 250 points and 10 devices. The INMBSMEB0100000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of M-Bus Meters from a Modbus BMS, SCADA, PLC or any other device working as a Modbus Master.The aim of this integration is to make available signals and resources of meters connected to M-Bus, from a Modbus master device or system. For this In..
2 670,83 zł
HD67029-B2-232-250
3-4 days
Brand: ADF Web Model: HD67029-B2-232-250
Industrial MBus to Modbus RTU Converter, Master MBus: up to 250 slaves - Modbus Slave Port: RS-232). The converter for communication with meters uses the MBus, RS-232 connector is used for Modbus RTU communication. The HD67029M-232-250 converter can read up to 250 MBus receivers of any type (eg water meters, gas meters, energy meters). Converter is easy to configure thanks to free SW67029 software.New converter functionality - automatic scan of M..
3 548,26 zł
HD67029-B2-485-250
3-4 days
Brand: ADF Web Model: HD67029-B2-485-250
Industrial MBus to Modbus RTU converter, master MBus up to 250 slaves, modbus slave Port: RS485. The converter for communication with meters uses the MBus, RS-485 connector is used for Modbus RTU communication. The HD67029M-485-250 converter can read up to 250 MBus receivers of any type (eg water meters, gas meters, energy meters). Converter is easy to configure thanks to free SW67029 software.New converter functionality - automatic scan of MBus ..
3 548,26 zł
HD67044-B2-250 HD67044-B2-250
3-4 days
Brand: ADF Web Model: HD67044-B2-250
Industrial MBus to Modbus TCP converter, master MBus up to 250 slaves, modbus slave port: Ethernet, housing type B (wide), DIN rail mount. The converter for communication with meters uses the MBus, Ethernet connector is used for Modbus TCP communication. The HD67044-B2-250 converter can read up to 250 MBus receivers of any type (eg water meters, gas meters, energy meters). Converter is easy to install and configure thanks to free SW67044 software..
3 707,35 zł
INMBSMEB0600000
5-7 days
Brand: Intesis Model: INMBSMEB0600000
M-Bus to Modbus Gateway for 1500 points and 60 devices. The INMBSMEB0600000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of M-Bus Meters from a Modbus BMS, SCADA, PLC or any other device working as a Modbus Master.The aim of this integration is to make available signals and resources of meters connected to M-Bus, from a Modbus master device or system. For this I..
5 158,47 zł
INMBSMEB1200000
5-7 days
Brand: Intesis Model: INMBSMEB1200000
M-Bus to Modbus Gateway for 3000 points and 120 devices. The INMBSMEB1200000 IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of M-Bus Meters from a Modbus BMS, SCADA, PLC or any other device working as a Modbus Master.The aim of this integration is to make available signals and resources of meters connected to M-Bus, from a Modbus master device or system. For this ..
7 086,87 zł