Bare wires made of AlMgSi alloy for overhead power lines. Characteristics:Material: AlMgSi alloy wires type AL3 according to PN-EN 50183Structure of the wire: Wires twisted in coaxial layers, directions of twisting opposite layers, direction of the outer layer should be rightApplication: For the construction of overhead power linesPacking: On drumsComplies with: PN-EN 50182..
Self-supporting cable (s) with a conductor of aluminum alloy (AA) in the insulating coating of crosslinked polyethylene resistant to sunlight (XS), and the spread of the flame (n). Construction:Conductor: Condensed core of AlMgSi alloy, aluminum grade AL3 according to EN 50182; sealed with a special powder to prevent longitudinal moisture migrationInsulation: XLPE polyethylene insulation according to EN 50397-1: 2006Insulation color: BlackPropert..
Bare steel and aluminum wires for overhead power lines. Characteristics:Material:Hard aluminum wires according to PN-EN 60889Steel wires type ST1A according to PN-EN 50189Structure of the wire: Single or multi-wire core made of galvanized steel wires, lubricated, subsequent layers made of aluminum wires twisted concentrically, the twisting directions of adjacent layers must be opposite and the direction of the outer layer should be rightApplicati..
Aluminum bare wires for overhead power lines. Characteristics:Material: Hard aluminum wires according to PN-EN 60889Structure of the wire: Wires twisted with concentric layers, directions of twisting of adjacent opposing layers, direction of the outer layer should be rightApplication: For the construction of overhead power linesPacking: On drumsComplies with: PN-EN 50182..
Self-supporting power cables with aluminum cores and cross-linked polyethylene insulation, resistant to flame propagation. One and multi-core, rated voltage: 0.6 / 1 kV.Construction:Veins: Aluminum, round, compactedCore insulation: Cross-linked polyethylene, resistant to flame propagationMarking: Digital printing or longitudinal notches, the number of which corresponds to the number of the vein. In 6-core cables, the wires with reduced cross-sect..
Copper bare wires for overhead power lines. Characteristics:Material: Hard wires according to ZN-PBP-213:1997 from copper Cu-ETP according to PN-EN 1977Explanation of markings:Cable D 4 mm² - ZN-PBP-213: 1997 - Copper single-wire conductor (D) with rated cross-section (4 mm²)Cable L 25 mm² - Multi-strand bare copper wire (L) with rated cross-section (25 mm²)Structure of a multi-conductor wire: Wires twisted with concentric layers, directions of t..
Fire-resistant safety cables, halogen-free, low-emission, shielded.For use where special protection of people, cultural and material assets is required. It ensures the functioning of warning systems, fire extinguishing, emergency lighting ventilation, smoke dampers and other, whose operation is necessary for effective rescue operation.Construction:Wires: Made of solid soft copper wire class 1 (RE) or twisted multi-wire class 2 (RM) according to E..
Fire-resistant safety cables, halogen-free, low-emission, shielded.For use where special protection of people, cultural and material assets is required. It ensures the functioning of warning systems, fire extinguishing, emergency lighting ventilation, smoke dampers and other, whose operation is necessary for effective rescue operation.Construction:Wires: Made of solid soft copper wire class 1 (RE) or twisted multi-wire class 2 (RM) according to E..
Fire-resistant safety cables, halogen-free with low smoke emission.Halogen-free and fire-proof electric and signal cables are designed for applications where special protection of people, cultural and material assets is required. They ensure the functioning of warning systems, fire extinguishing, power emergency lighting, ventilation, smoke dampers and other, whose operation is necessary for the effective conduct of rescue operations.Construction..
Fire-resistant safety cables, halogen-free with low smoke emission. Halogen-free and fire-proof electric and signal cables are designed for applications where special protection of people, cultural and material assets is required. They ensure the functioning of warning systems, fire extinguishing, power emergency lighting, ventilation, smoke dampers and other, whose operation is necessary for the effective conduct of rescue operations.Constructio..
Halogen-free, flame-retardant cables with low smoke emission.Intended for use as power and signaling cables in facilities with stricted fire-fighting requirements (hotels, hospitals, offices, airports, shopping centers, industrial facilities, etc.). Recommended for use in emergency lighting installations, smoke extractors, alarm, signaling, control systems, fire alarms and fire alarm systems as well as other safety circuits.The cables must be fas..
Single core cables for permanent installation, low smoke emission and corrosive gases during smoking. ApplicationIn electrical engineering, control cabinets, switching stations, automation devices, as well as in lighting equipment and installations, in facilities with stricter fire-fighting requirements. Intended for laying in installation pipes mounted outside or embedded in the ground, or similar closed systems. For permanently protected instal..