To be confirmed
Wires with insulation and rubber coating for lifting equipment, transport equipment and conveyors.
Cables are used where there is frequent winding and unwinding during operation, especially with simultaneous tensile load and / or twisting load and / or forced cable routing. Perfect for use in construction, mines, mobile shearers, cranes, conveyors, high mechanical loads, especially at high dynamic tensile loads, e.g. at high acceleration. High resistance to oils, greases, chemicals and moisture, to the spread of flame.
Construction:
- Core: Copper tinned round multi-wire class 5 according to DIN-EN 60228
- Insulation: Rubber compound type 3GI3 according to VDE 0207 part 20
- Inner coating: Rubber compound type GM1b according to VDE 0207 part 21
- Reinforcement braid: With plastic thread
- Outer shell: 5GM3 rubber compound according to VDE 0207 part. 21
- Coating color: Black
- Identification of veins:
- 3-wire: green-yellow, blue, brown
- 4-wire: green-yellow, brown, black, gray
- 5-wire: green-yellow, blue, brown, black, gray
- over 5 veins: green-yellow (in the outer layer), other blacks with digital overprint
Characteristic:
- Maximum temperature of the conductor during cable operation: + 90°C
- The minimum ambient temperature for laying cables: - 25°C
- Maximum core temperature during short circuit: + 200°C
- Maximum permissible load: 15 N per mm² of copper cross-section
- Resistance to flame spread: PN-EN 60332-1-2
- Test voltage testing: 2500V
- Standard packaging: On drums of 500 m or 1000 m. It is possible to offer other lengths of sections and types of packaging
Compliant with: DIN VDE 0250-814
Industrial grade | |
Operating temperature | to 90°C |
Cable parameters | |
Minimum bending radius | 1D, 2D, 3D, 4D, 6D, 7.5D, 5D, 10D, 12D, 15D |
Core | Copper |
Insulation | Rubber |
Installation temperature | -25°C to 90°C |
Inner coating | Rubber compound |
Outer coating | Rubber compound |
Maximum short circuit temperature | 200°C |
Test voltage | 2.5 kV |
Standard packaging | On drums |
Resistance to flame spread | EN 60332-1-2 |
Outer diameter [mm] | 13.3, 14.1, 14.7, 15.0, 16.5, 16.9, 17.4, 18.0, 18.1, 18.5, 18.6, 19.2, 19.6, 19.9, 20.3, 22.5, 24.2, 25.0, 27.3, 28.0, 28.9, 29.4, 29.6, 31.1, 31.5, 32.2, 32.3, 32.5, 33.1, 33.2, 33.5, 33.7, 34.9, 37.3, 38.9, 42.1, 42.8, 43.4, 46.5, 50.0, 51.7, 52.3, 54.3, 57.2, 58.7, 63.4, 64.2, 69.0 |
Cable weight [kg/km] | 211, 244, 269, 272, 346, 366, 392, 394, 404, 439, 463, 478, 520, 544, 571, 727, 761, 878, 902, 961, 1004, 1012, 1164, 1185, 1242, 1301, 1391, 1400, 1641, 1698, 1820, 1821, 1837, 2021, 2249, 2596, 3213, 3335, 4165, 4458, 5016, 5272, 5562, 6401, 6873, 8350, 9126, 10555 |
Working conductor cross section [mm2] | 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 240.0 |
1