To be confirmed
Power cables 3 and 4-core wires with insulation and rubber tire for rated voltage 0.6 / 1kV for deep-water engines.
It is recommended:
- to use wire in a well at a depth of immersion up to 20m
- to not install cables at a temperature lower than -10 ° C
- that the radius of bending expressed in multiples of the outside diameter of duct D is not less than 5D
It is allowed:
- to use in conductors with veins made of wires with a nominal diameter of 0.31 mm and larger use of a separator made of polyester or paper tape, in which case they do not have to be tinned wires
- Tinning of wires intended only for a layer of a wire directly in contact with the rubber insulation
Construction:
- Working and protective conductors: Copper multi-wire according to PN-EN 60228 class 5 (tinned wires)
- Separator: Polyester film or telephone paper
- Insulation: Made of rubber IZ according to PN-89 / E-29100
- Insulation color:
- 3-wire: blue, black, brown
- 4-wire: green-yellow, blue, black, brown
- Tire: Of type OZ3 rubber according to PN-89 / E-29100
- Tire color: Black
Characteristic:
- Application: For powering electric motors of submersible pumps working in a moderate climate
- Explanation of the letter code of the wire: OGŁ - Copper conductor with insulation and rubber tire (O), for deep water engines (GŁ)
- Example of wire marking:
- 3-wire OGŁ wire for 6/1 kV, 16mm² cross-section
- Wire OGŁ 0.6 / 1 kV 3x16mm² ZN-95 / MP-13-K12 192
- Working temperature: In water and air from -40 ° C to + 60 ° C
- Test voltage: 3 kV - before the test The cable is immersed in water at 20 ± 5 ° C for the duration of:
- 12h - in the case of a full test
- 6h - in the case of an incomplete examination
- Packing: On drums
Compliant with: ZN-95 / MP-13-K12 192
Industrial grade | |
Operating temperature | -40°C to 60°C |
Cable parameters | |
Core | Copper |
Insulation | Rubber |
Test voltage | 3 kV |
Standard packaging | On drums |
Tire | Rubber |
Number of wires in the cable | Multi-core |
Outer diameter [mm] | 12.8, 13.7, 15.3, 16.4, 16.9, 18.2, 19.5, 21.1, 23.8, 25.8, 28.3, 30.7, 33.4, 35.9, 36.4, 39.1, 40.6, 44.0, 44.3, 48.0, 54.9 |
Cable weight [kg/km] | 170, 195, 230, 335, 365, 375, 460, 615, 750, 880, 1085, 1255, 1560, 1610, 2010, 2070, 2290, 2840, 3040, 3800, 4945 |
Working conductor cross section [mm2] | 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0 |
1