Menu
Your Cart

KNX to Modbus converters for building automation, compatible with ETS software

Industrial KNX to Modbus converters

In this section of our shop you will find converters from the KNX interface to Modbus TCP or RTU. KNX is a communication protocol used in industrial automation (mainly building automation) for, among other things, communication with air conditioning, heating, lighting, but also temperature sensors, control of blinds, light switches, actuators or alarms. The converters allow the integration of all KNX devices into a Modbus TCP or RTU network (e.g. control systems, controllers, SCADA system or BMS).

Learn more about our KNX to Modbus converters

The KNX to Modbus converters available in our range offer a wide supply voltage range of 12-35VDC or a battery range of 24VAC, easy DIN rail mounting, resistance to electromagnetic interference and the ability to be installed in harsh environments with a wide operating temperature range of -40°C to 85°C. The industrial design and specification of the converters guarantees long, trouble-free operation of the gateways on site and allows them to be installed both in freezing temperatures and in cabinets that generate significant heat.

Our KNX to Modbus converters are devices that support KNX, Ethernet (RJ45 connector for Modbus TCP programming and communication) and RS-232 and RS-485 (screw connectors for Modbus RTU communication) ports. Thanks to the free software included with each unit, the converters are very easy to configure and do not require any additional licences. Depending on the model, the converters are limited in the number of variables that can be mapped. ADFweb converters are limited to 1440 bytes in read and write, while Intesis gateways are divided into models according to the number of variables supported. On the Modbus side, the converters can act as both Modbus master and Modbus slave, depending on the version. All converters are compatible with the ETS software.

Select the KNX to Modbus converter you are interested in and read the detailed technical description:

HD67812-KNX-232-B2 HD67812-KNX-232-B2
3-4 days
Brand: ADF Web Model: HD67812-KNX-232-B2
Industrial Modbus RS232 master to KNX TP converter, housing type B (wide), DIN rail mount. HD67812 allows to communicate KNX TP with RS232 Modbus RTU devices like SCADA, HMI or Modbus controllers. Converter is easy to use thanks to free SW67812 software.Configuration:Thanks to the SW67812 software on your PC you can:Define the parameters of Modbus lineDefine the parameters of KNX lineDefine the KNX messages that the Converter can acceptDefine the..
1 586,11 zł
HD67812-KNX-485-B2
3-4 days
Brand: ADF Web Model: HD67812-KNX-485-B2
Industrial Modbus RS485 master to KNX TP converter, housing type B (wide), DIN rail mount. HD67812 allows to communicate KNX TP with RS485 Modbus RTU devices like SCADA, HMI or Modbus controllers. Converter is easy to use thanks to free SW67812 software.Configuration:Thanks to the SW67812 software on your PC you can:Define the parameters of Modbus lineDefine the parameters of KNX lineDefine the KNX messages that the Converter can acceptDefine the..
1 586,11 zł
HD67813-KNX-232-B2
3-4 days
Brand: ADF Web Model: HD67813-KNX-232-B2
Industrial Modbus RS232 slave to KNX TP converter, housing type B (wide), DIN rail mount. HD67813 allows to communicate KNX TP with RS232 Modbus RTU devices like SCADA, HMI or Modbus controllers. Converter is easy to use thanks to free SW67813 software.Configuration:Thanks to the SW67813 software on your PC you can:Define the parameters of Modbus lineDefine the parameters of KNX lineDefine the KNX messages that the Converter can acceptDefine the ..
1 586,11 zł
HD67813-KNX-485-B2
3-4 days
Brand: ADF Web Model: HD67813-KNX-485-B2
Industrial Modbus RS485 slave to KNX TP converter, type B (wide) housing, DIN rail mounting. HD67813 allows communication between KNX devices such as air conditioning, heating, lighting, security systems and Modbus RTU devices with RS485 such as controllers or HMI panels. The product features a capacity of up to 1440 bytes for both reading and writing data. An important aspect is the triple isolation between the different parts of the device: KNX..
1 586,11 zł
HD67814-KNX-B2 HD67814-KNX-B2
3-4 days
Brand: ADF Web Model: HD67814-KNX-B2
Industrial Modbus TCP master to KNX TP converter, housing type B (wide), DIN rail mount. HD67814 allows to connect Modbus TCP slaves with KNX network (for example light switches or actuators). Converter is easy to install and configure thanks to free SW67814 software available with device.Configuration:Thanks to the SW67814 software on your PC you can:Define the parameters of Modbus TCP lineDefine the parameters of KNX lineDefine the KNX messages..
2 116,42 zł
HD67815-KNX-B2
3-4 days
Brand: ADF Web Model: HD67815-KNX-B2
Industrial Modbus TCP slave to KNX TP converter, housing type B (wide), DIN rail mount. HD67815 allows to connect Modbus TCP masters (SCADA or PC) with KNX networ. Converter is easy to install and configure thanks to free software SW67815.Configuration:Thanks to the SW67815 software on your PC you can:Define the parameters of Modbus TCP lineDefine the parameters of KNX lineUpdate the deviceCharacteristics:Up to 1440 bytes in reading and 1440 byte..
2 116,42 zł
INKNXMBM1000200
5-7 days
Brand: Intesis Model: INKNXMBM1000200
INKNXMBM1000200 Modbus RTU Client to KNX TP Gateway - 100 pointsIntegrate any Modbus RTU server device with any KNX device or system using ETS. The aim of this integration is to make accessible any Modbus registers data and resources from a KNX system, as if it was part of the own KNX system and vice-versa.Features:KNX CertifiedSupport for Modbus RTU only (RS485)Support for KNX TPSupports KNX standard datapoints (DPTs) that guarantees a seamless ..
2 415,32 zł
INMBSKNX1000000
5-7 days
Brand: Intesis Model: INMBSKNX1000000
KNX to Modbus Gateway. Model INMBSKNX1000000 Modbus Server RTU &TCP - KNX- 100 points. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. This bidirectional INMBSKNX1000000 gateway provides a stra..
3 316,85 zł
IBOX-MBS-KNX IBOX-MBS-KNX
5-7 days
Brand: Intesis Model: IBOX-MBS-KNX
KNX to Modbus Gateway. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to it..
3 471,12 zł
INMBSKNX2500000
5-7 days
Brand: Intesis Model: INMBSKNX2500000
KNX to Modbus Gateway. Model INMBSKNX2500000 Modbus Server RTU &TCP - KNX- 250 points. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. This bidirectional INMBSKNX2500000 gateway provides a str..
4 883,67 zł
INMBSKNX6000000
5-7 days
Brand: Intesis Model: INMBSKNX6000000
KNX to Modbus Gateway. Model INMBSKNX3K00000 Modbus Server RTU &TCP - KNX- 600 points. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. This bidirectional INMBSKNX6000000 gateway provides a st..
6 228,73 zł
IN701KNX6000000
5-7 days
Brand: Intesis Model: IN701KNX6000000
KNX to Modbus Gateway. Model IN701KNX6000000 Modbus Server RTU &TCP - KNX- 600 points. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX communication objects and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa. This bidirectional gateway provides a straightforward and..
6 604,77 zł
Showing 1 to 12 of 14 (2 Pages)
We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.