Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV.Construction:Working, protective and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228Separator: On operating wires made of polyester filmInsulation: IEP heat-resistant rubber accordin..
Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV.Construction:Working resins: Copper multi-wire class 5 acc. PN-EN 60228Auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228Protective conductor: Made in the form of a braid made of tinned..
Power cables for mobile and portable receivers. Mining shielded cables with six working conductors for rated voltage of 1.9 / 3.3 kV.Construction:Working, protective and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228Separator: Coils made of polyester film on working veinsInsulati..
A power cable with insulation and a rubber tire for mobile and mobile receivers shielded to 3.6 / 6 kV. Construction:Working and protective conductors: Copper, copper tinned multi-wire class 5 according to PN-88 / E-60228Insulation: Made of heat-resistant rubber IEP according to PN-E 29100The color ..
Single-core power cables with insulation and rubber tire for mining mobile and portable receivers for nominal voltage 0.6 / 1kV.Construction:Wire: Copper multi-wire class 5c (tinned) according to PN-88 / E-90160Separator: On operating wires made of polyester filmInsulation: Made of rubber IZ accordi..
Power cables with insulation and rubber tire for mining mobile and portable receivers, multicore unshielded for rated voltage 0.6 / 1kV.Construction:Wire: Copper multi-wire class 5c (tinned) according to PN-88 / E-90160Separator: On operating wires made of polyester filmInsulation: Made of rubber IZ..
Power cables with insulation and rubber tire for mining mobile and portable receivers, multicore unshielded for rated voltage 0.6 / 1kV.Construction:Wire: Copper multi-wire class 5c (tinned) according to PN-88 / E-90160Insulation: Made of rubber IZ according to PN-89 / E-29100Color of insulation:2-w..
Miner tire unground wires with insulation and rubber tire for rated voltage 0.6 / 1 kV.Construction:Veins:Multi-wire copper according to PN-88 / E-90160Class 5 workplaceProtective class 5c (tin plated)Separator: On working conductors made of polyester film or paperInsulation: On working conductors m..
Miner shielded tire duct with insulation and rubber tire for 3.6 / 6 kV voltage.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989The color of the insulation of the veins: Nat..
Mineral shielded tire duct with insulation and rubber tire for 6/10 kV voltage. Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989The color of the insulation of the veins: Nat..
Power cables for mobile and portable receivers. Mining wires shielded at rated voltage 0.6 / 1 kV.Construction:Working, protective and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228Separator: On operating wires made of polyester filmInsulation: IEP heat-resistant rubber according..
Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV.Construction:Working cores: Copper multi-wire class 5 acc. PN-EN 60228Auxiliary cores: Copper tinned multi-wire class 5 acc. PN-EN 60228Protective conductor: Made in the form of a braid made of tinned ..
Mining tire ducts with two screens for rated voltage 3.6 / 6 kV. Construction:Working and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228, protective conductor are connected screens of working and auxiliary conductorsSeparator: On operating conductors made of polyester film or oth..
Mining wires with insulation and rubber tire with individually shielded wires for nominal voltage 0.6 / 1 kV.Construction:Working, protective and auxiliary veins: Copper tinned multi-wire class 5c according to PN-88 / E-90160Insulation: IEP heat-resistant rubber according to PN-89 / E-29100Screen: I..
Mining wires shielded for rated voltage 18/30 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 19..
Minerals shielded for rated voltage 3.6 / 6 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989..
Mining wires shielded for rated voltage 6/10 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 198..
Mining wires shielded for rated voltage 18/30 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 19..
Minerals shielded for rated voltage 3.6 / 6 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989..
Mining wires shielded for rated voltage 6/10 kV.Construction:Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989Insulation: IEP heat-resistant rubber according to PN-E 29100: 198..