Industrial IEC 61850 Server to BACnet MSTP Master - Converter, housing type A (slim), DIN rail mount. HD67737-MSTP-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc.) with some BACnet slaves in order to exchange informations between the nets. Specifications:Ports: 2xEthernetBACnet protocol: BACnet IP MasterIEC 61850 protocol: ServerData Rates BACnet: 10/100 Base-T Autosensing Data Rates IEC 61850: 10/100 Base-T A..
Industrial IEC 61850 Server to BACnet IP Slave Converter, housing type A (slim), DIN rail mount. HD67738-IP-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc.) with a BACnet Master in order to exchange informations between the BACnet Master (for example a Supervisory System, PLC, etc.) and the IEC 61850 network. Specifications:Ports: 2xEthernetBACnet protocol: BACnet IP SlaveIEC 61850 protocol: ClientData Rates BA..
Industrial IEC 61850 Server to BACnet MSTP Slave Converter, housing type A (slim), DIN rail mount. HD67738-MSTP-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc.) with a BACnet Master in order to exchange informations between the BACnet Master (for example a Supervisory System, PLC, etc.) and the IEC 61850 network. Specifications:Ports: 2xEthernetBACnet protocol: BACnet MSTP SlaveIEC 61850 protocol: ClientData Ra..
Industrial IEC 61850 Server to MQTT Converter, housing type B, DIN rail mount. HD67747-B2 allows you to connect an IEC 61850 Client network (for example a SCADA, HMI etc.) with a MQTT net in order to exchange informations between the nets. Specifications:Ports: 1xEthernetEthernet protocol: MQTTIEC 61850 protocol: ServerData Rates MQTT: 10/100 Base-T AutosensingData Rates IEC 61850: 10/100 Base-T AutosensingMQTT connector: RJ45IEC 61850 connector..
Industrial IEC 61850 Server to SNMP Manager Converter, housing type A, DIN rail mount. HD67753-A1 allows you to can can connect an IEC 61850 Client network (for example a SCADA, HMI etc.) with some SNMP devices in order to exchange informations between the nets. Specifications:Ports: 2xEthernet;Ethernet protocol: SNMP ManagerIEC 61850 protocol: ServerData Rates SNMP: 10/100 Base-T AutosensingData Rates IEC 61850: 10/100 Base-T AutosensingSNMP co..
Industrial IEC 61850 Server to SNMP Agent Converter, housing type A, DIN rail mount. HD67754-A1 allows you to can connect an IEC 61850 Client network (for example a SCADA, HMI etc.) with an SNMP Manager in order to exchange informations between the nets. Specifications:Ports: 2xEthernet;Ethernet protocol: SNMP AgentIEC 61850 protocol: ClientData Rates SNMP: 10/100 Base-T AutosensingData Rates IEC 61850: 10/100 Base-T AutosensingSNMP connector: R..
Industrial IEC 61850 server to serial converter (RS232), housing type A (slim), DIN rail mount. HD67755-2-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc.) with some serial devices slaves in order to exchange informations between the nets. Specifications:Ports: 2xEthernet; 1xRS232Serial: Serial RS232IEC 61850 protocol: IEC 61850 server Data Rates serial: Up to 115200 bps Data Rates IEC 61850: 10/100 Base-T Autose..
Industrial IEC 61850 server to serial converter (RS485), housing type A (slim), DIN rail mount. HD67755-5-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc.) with some serial devices slaves in order to exchange informations between the nets. Specifications:Ports: 2xEthernet; 1xRS485Serial: Serial RS485IEC 61850 protocol: IEC 61850 server Data Rates serial: Up to 115200 bps Data Rates IEC 61850: 10/100 Base-T Autose..
Industrial IEC 61850 Server to Ethernet Converter, housing type A (slim), DIN rail mount. HD67756-A1 allows you to connect an IEC 61850 Client network (for example a SCADA, HMI etc.) and interface this by Ethernet in order to exchange informations between the nets. Specifications:Ports: 2xEthernetEthernet protocol: CANopenIEC 61850 protocol: ServerData Rates Ethernet: 10/100 Base-T AutosensingData Rates IEC 61850: 10/100 Base-T AutosensingEthern..
The HD67766-A1 is a IEC61850 Client / Modbus TCP Slave converter. <HD67766-A1 allows you to connect a IEC 61850 Client network (for example a SCADA, HMI etc..) with a Modbus TCP Master in order to exchange informations between the Modbus TCP Master (for example a PLC, etc..) and the IEC61850 network. Configuration:You need Compositor SW67766 software on your PC in order to perform the following:Define the parameters of the IEC61850Define the p..