PROFIBUS Remote I/O Module with 24 Isolated Digital Outputs. The PROFI-5045 is one of the PROFIBUS DP series products produced by ICP DAS. It provides the PROFIBUS DP communication protocol with any DP-Masters. The PROFI-5045 provides ±4KV ESD protection contacting for all terminals (include I/O Terminals and PROFIBUS connector). By applying the PROFI-5045, users can easily establish a PROFIBUS DP network with other DP-Masters. In advance, it can..
I/O Expansion Unit with 8 Slots and 1x USB Port. USB-87Pn is an unit to expand I/O via the USB. It is designed to be used in harsh and noisy environment, so the hardware is manufactured with wide power input range (10 ~ 30 VDC), isolated power input and can operate under wide temperature (-25 ~ +75°C). To simplify installation and maintenance of I/O modules, it provides many useful features, such as: hot swap allowed, auto configuration, LED indi..
8-channel Analog Input Module using the DCON and Modbus Protocols. The I-7017R is an 8-channel analog input module with an extremely high quality protection mechanism where the overvoltage protection is 240 Vrms. The input type includes both voltage and current. The I-7017R is an upgraded version of the I-7017, with the only difference being that the I-7017R is much more suitable for critically harsh environments. The sampling rate of the I-7017R..
8-channel Analog Input Module using the DCON and Modbus Protocols with High Voltage Protection. The I-7018/M-7018 is an 8-channel Analog Input module that provides current and voltage input, as well as thermocouple input. The I-7018R/M-7018R is an upgraded version of the I-7018/M-7018 that includes an extremely high-quality protection mechanism where the overvoltage protection can be as high as 240 Vrms. The I-7018R/M-7018R is more suitable for c..
Programmable Intelligent Communication Controller with LED Display. 1x 5-wire RS-232 or 2-wire RS-485 port, 1 RS-422 port and 1 RS-485 port.Onboard 1 KB Queue bufferThe I-752N series module is equipped with a 1 KB queue buffer for its local RS-232 device. All input data can be stored in the queue buffer until the Host PC has time to read it. This feature allows the Host PC to link thousands of RS-232 devices without any loss of data.3000V isolati..
Industrial USB to DeviceNet Master Converter. I-7565-DNM can represent an economic solution of DeviceNet application and be a DeviceNet master device on the DeviceNet network. It is a "Predefined Master-Slave connection Set". I-7565-DNM supports Group 2 only Server and UCMM functions to communication with slave devices. It has an independent CAN bus communication port and has the ability to cover a wide range of DeviceNet applications.I-7565-DNM ..
Unmanaged 8-port 10/100/1000 Base-T Ethernet Switch with plastic casing. The NS-208G/NSM-208G has 8 Ethernet Switching ports that support 10/100/1000 Base-T, with a 10/100/1000M auto negotiation feature and auto MDI/MDI-X function. It can connect 8 workstations and automatically switches the transmission speed (10 Mbps or 100 Mbps or 1000 Mbps) for corresponding connections.The flow control mechanism is also negotiated. There is link/data rate LE..
Ethernet I/O Module with 1 Ethernet PoE port, 8-ch Thermistor Inputs and 4-ch Digital Outputs. ET-7005/PET-7005 is used for measuring temperature by the thermistor. It supports many kinds of thermistors and features individual channel configuration which means that eight of its input channels can individually be configured with different kind of thermistor and supports user-defined types by specifying the Steinhart coefficients to add other therm..
Ethernet I/O Module with 1 Ethernet Port and 7 RTD Inputs. The ET-7015/PET-7015/ET-7215/PET-7215 is specifically designed for long-distance RTD measurement. It features automatic compensation for three-wire RTD regardless of the length of wires and provides open wire detection for RTD measurement. The ET-7015/PET-7015/ET-7215/PET-7215 offers 7 channels, each of which could be connected with different kinds of RTD (Pt100, Pt1000, Ni120, Cu100, Cu1..
4-channel Analog Output Module using the DCON Protocol. The I-7024 is a 14-bit 4-channel analog output module that provides current and voltage outputs. There are options for power-on values and safe values. It features 3000 VDC intra-module isolation. The I-7024R is the same as the I-7024 and provides additional 5-channel digital inputs and 4 KV ESD protection on each terminal. The M-7024/M-7024R support Modbus RTU and DCON protocols and can be ..
10-channel Thermocouple Input Module. The “Z” version is another milestone in the development of I-87018 and a testament to excellence by ICP DAS R&D team. I-87018ZW is specifically designed for extremely accurate thermocouple measurement. It features automatic compensation for each channel. Current input and voltage input are supported. Another feature is that ten of its input channels can individually be configured with different kinds of a..
16-channel Analog Input Module using the DCON and Modbus Protocols. The M-7018-16 is an analog input module that includes 16 differential analog input channels. The voltage input range can be from ±15 mV to ±2.5 V, the current input range can be either +4 to +20 mA, 0 to +20 mA, or ±20 mA, and types J, K, T, E, R, S, B, N, C, L, M, LDIN43710 thermocouple can be used for the thermocouple input. Overvoltage protection of up to 30 VDC is provided. T..