8-channel Differential/16-channel Single-ended Analog Input Module. The I-87017DW is a 8-channel differential/16-channel single-ended analog input module. The analog input range is software selectable and supports +/-10 V, +/-5 V, +/-1 V, +/-500 mV, +/-150 mV, 0 ~ +20 mA, +4 ~ +20 mA, and +/-20 mA. And all channels support 240 Vrms overvoltage protection in differential mode. Differential mode and single-ended mode is selected via jumper selectab..
1/8-channel Vibrating Wire Input Module. The vibrating wire sensor has a wire which is initially plucked by a series of electrical magnetic forces from a coil. The conductive wire after plucking is vibrating in a magnetic field. The wire will disturb the field, and then the coil can pick up the induced voltage change. The signal is amplified and detected by a VW readout device, or called VW reader. After plucking, there is no other force acting o..
1-channel RTD Input Module using the DCON and Modbus Protocols with 7-segment LED Display. The I-7013(D) and M-7013P(D) is a 1-channel RTD Input module that is used for measuring temperatures via an RTD sensor and supports Pt100, Ni120, and Pt1000 type sensors. The module allows 2/3/4-wire RTD connections and features open wire detection. In addition, the I-7013(D) and M-7013P(D) also includes 3000 VDC intra-module isolation and supports lead res..
Ethernet PoE I/O Module with 8-channel Isolated Source Type Open Collector Output and 8-channel Digital Input. WISE-7255 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables a..
The BAST-221C-BW2 wireless thermostat model is BACnet/IP connected using a wireless connection to a nearby Wi-Fi router/access point which supports IEEE 802.11b/g/n. The respective maximum indoor range is 115 ft. for IEEE 802.11b, 125 ft. for IEEE 802.11g, and 225 ft. for IEEE 802.11n considering there are little to no substantial obstructions between the Wi-Fi router and the thermostats which is the case in most standard buildings. Some buildin..
I/O BACnet MS/TP Module with 4 digital inputs and 2 relay outputs.For those installations that support a fieldbus solution such as BACnet MS/TP, Contemporary Controls provides solutions for expanding the number of I/O points in the field. These compact cost-effective modules are available with analog and digital inputs and outputs in varying combinations. The BACnet MS/TP module with 4 digital inputs and 2 relay outputs with manual control was..
MQTT I/O Module with 2-port Ethernet Switch, 8 Digital Inputs (Dry/Wet contact) and 8 Digital Outputs. The MQ-7244M, MQ-7252M and MQ-7255M are Ethernet I/O devices equipped with 8-channel DI and 8-channel DO, as well as the MQTT protocol is supported for connecting with a variety of digital sensors in Industrial Internet of Things (IIoT) applications. A web-based user interface is provided to configure module, monitor the network connection statu..
CANopen Remote I/O Unit with 1 Expansion Slot. The CAN-8x23 main control unit is specially designed for the slave device of CANopen protocol. It follows the CANopen Spec DS-301 V4.02 and DSP-401 V2.1, and supplies many features for users, such as dynamic PDO, EMCY object, error output value, SYNC cyclic and acyclic, etc.The CAN-8x23 supports up to 1/2/4/8 slots for I/O expansion and suits with a lot of ICP DAS DI/AI/DO/AO modules. User can choose..
DeviceNet Remote I/O Unit with 1 I/O Expansion Slot. The CAN-8124/CAN-8224 main control unit is specially designed for the slave device of DeviceNet protocol. It follows the Specification of DeviceNet. In order to expand I/O channel more flexible, an CAN-8x24 supports 1/2/4 slot(s) for I/O expansion and suits with a lot of ICP DAS DI/AI/DO/AO modules.Users can choose DI/DO/AI/AO modules of I-87K series or I-8000 series to fit the customized pract..
Ethernet I/O Module with 1 Ethernet port, 8-ch Thermistor Inputs and 4-ch Digital Outputs. ET-7005/PET-7005 is used for measuring temperature by the thermistor. It supports many kinds of thermistors and features individual channel configuration which means that eight of its input channels can individually be configured with different kind of thermistor and supports user-defined types by specifying the Steinhart coefficients to add other thermisto..
1-channel Transmitter Input Module with 7-segment LED Display using the DCON and Modbus Protocols. The I-7014 is an 1-channel Transmitter Input module that provides a +15 VDC isolated loop power supply for transmitter input, and is designed for both voltage and current input types. In addition, the module provides 1 Digital Input channel as a 50 Hz event counter and 2 Digital Output channels that can be used as a high/low alarm. The I-7014 also f..
Industrial Universal PCI card with 16 isolated Digital Inputs and 16 Open-collector Digital Outputs (Sink, NPN). The PCI-P16C16U universal PCI card supports 3.3 V/5 V PCI bus. These cards contain 16 optically isolated Digital Input channels and 16 open collector (Sink, NPN) Digital Output channels. The DI channels provide 5000 Vrms isolation protection that allows the input signals to be completely floated so as to prevent ground loops and isolat..