Communication Modules for Bosch Air Conditioners – Quick BMS Integration and Remote Control

Communication modules for Bosch air conditioners

Are you looking for a way to better manage your Bosch air conditioners? Our communication modules allow you to integrate your Bosch air conditioners with master systems and devices using various industrial protocols. They give you full control over your units - remote management, rapid fault diagnosis, temperature and air conditioner output control. This not only saves time, but also energy and resources, which will significantly extend the life of your equipment.

What protocols do the communication modules support?

Our communication modules allow Bosch air conditioners to integrate with popular protocols such as:

  • Bosch air conditioner module on Modbus
  • Bosch air conditioner module on KNX

If you are not sure if your Bosch air conditioner is compatible with our module, contact our expert who will help you find the right solution. We are here to provide you with support and maximum product matching.

For your convenience, all communication modules are grouped by air conditioner model. Simply select the model you are interested in and the detailed technical description will help you make the right decision.

INKNXACA001I000
5-7 days
Brand: Intesis Model: INKNXACA001I000
Bosch Commercial & VRF systems to KNX Interface- 1 unitThe Bosch-KNX gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and KNX installations.The gateway is wired directly to an indoor or outdoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint but the monitoring of errors, alarms and some internal variables.Features:KNX certifiedCon..
1 209,04 zł
INMBSACA001I000
5-7 days
Brand: Intesis Model: INMBSACA001I000
Bosch Commercial & VRF systems to Modbus RTU Interface - 1 unitThe INMBSACA001I000 Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks.Features:Modbus RTU (EIA485) slave deviceConfiguration from both onboard DIP-switches and Modbus RTUQuick and easy installation (plug and set the DP-SW)Simultaneous control of the AC unit by the IR remote controller and by Mod..
1 280,44 zł
INMBSACA004I000
5-7 days
Brand: Intesis Model: INMBSACA004I000
Bosch Commercial & VRF systems to Modbus RTU Interface - 4 unitThe INMBSACA004I000 Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks.Features:Modbus RTU (EIA485) slave deviceConfiguration from both onboard DIP-switches and Modbus RTUQuick and easy installation (plug and set the DP-SW)Simultaneous control of the AC unit by the IR remote controller and by Mod..
3 489,08 zł
INMBSACA008I000
5-7 days
Brand: Intesis Model: INMBSACA008I000
Bosch Commercial & VRF systems to Modbus RTU Interface - 8 unitThe INMBSACA008I000 Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks.Features:Modbus RTU (EIA485) slave deviceConfiguration from both onboard DIP-switches and Modbus RTUQuick and easy installation (plug and set the DP-SW)Simultaneous control of the AC unit by the IR remote controller and by Mod..
5 878,60 zł
INKNXACA016I000
5-7 days
Brand: Intesis Model: INKNXACA016I000
Bosch Commercial & VRF systems to KNX Interface- 16 unitThe INKNXACA016I000 Bosch-KNX gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and KNX installations.TheINKNXACA016I000 gateway is wired directly to an indoor or outdoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoin but the monitoring of errors, alarms and some internal vari..
8 510,88 zł
INMBSACA032I000
5-7 days
Brand: Intesis Model: INMBSACA032I000
Bosch Commercial & VRF systems to Modbus RTU Interface - 32 unitThe INMBSACA032I000 Bosch-Modbus gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and Modbus RTU (RS-485) networks.Features:Modbus RTU (EIA485) slave deviceConfiguration from both onboard DIP-switches and Modbus RTUQuick and easy installation (plug and set the DP-SW)Simultaneous control of the AC unit by the IR remote controller and by Mo..
8 782,20 zł
INKNXACA064I000
5-7 days
Brand: Intesis Model: INKNXACA064I000
Bosch Commercial & VRF systems to KNX Interface - 64 unitThe INKNXACA064I000 Bosch-KNX gateway allows fully bi-directional communication between Bosch Commercial and VRF systems and KNX installations.The gateway is wired directly to an indoor or outdoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint but the monitoring of errors, alarms and some internal variables.Feature..
16 279,20 zł