1-channel Thermocouple Input Module using the DCON Protocol with LED Display. The I-7011 series of modules feature current and voltage input, as well as thermocouple input. The module provides 1-channel Analog Input, 1-channel Digital Input that functions as a 50 Hz event counter, and 2-channel Digital Output that can be used as a high/low alarm. The module also features open wire detection for the thermocouple input, and 3000 VDC intra-module is..
8-channel Differential/16-channel Single-ended Analog Input Module. The I-87017DW is a 8-channel differential/16-channel single-ended analog input module. The analog input range is software selectable and supports +/-10 V, +/-5 V, +/-1 V, +/-500 mV, +/-150 mV, 0 ~ +20 mA, +4 ~ +20 mA, and +/-20 mA. And all channels support 240 Vrms overvoltage protection in differential mode. Differential mode and single-ended mode is selected via jumper selectab..
1-channel Transmitter Input Module with 7-segment LED Display using the DCON and Modbus Protocols. The I-7014 is an 1-channel Transmitter Input module that provides a +15 VDC isolated loop power supply for transmitter input, and is designed for both voltage and current input types. In addition, the module provides 1 Digital Input channel as a 50 Hz event counter and 2 Digital Output channels that can be used as a high/low alarm. The I-7014 also f..
8-channel Analog Input Module using the DCON Protocol. The I-7017R is an 8-channel analog input module with an extremely high quality protection mechanism where the overvoltage protection is 240 Vrms. The input type includes both voltage and current. The I-7017R is an upgraded version of the I-7017, with the only difference being that the I-7017R is much more suitable for critically harsh environments. The sampling rate of the I-7017R is adjustab..
6-channel Analog Input, 2-channel Analog Output, 2-channel Digital Input and 2-channel Digital Output Module. The 87026PW is a multifunction module that includes 6 analog input channels, 2 analog output channels, 2 digital input channels, 2 digital output channels. It provides a programmable input range on all analog input (+/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V, +/-20 mA, 0 ~ 20 mA or 4 ~ 20 mA), analog outputs are 12 bit at +/-5 V, +/-10..
4-channel 14-bit Analog Output Module. The I-87024W is a 4-channel analog output module that provides either current or voltage output. There are options to set Power-on and safe values. The I-87024W also features 4 kV ESD protection and 3000 VDC intra-module isolation.The I-87024RW is a 4-channel analog output module. The programmable AO channels provide 14-bit resolution and support an output range of 0 ~ +5 V, ±5 V, 0 ~ +10 V, ±10 V, 0 ~ +20 m..
2-channel Strain Gauge Input Module using the DCON Protocol. The I-7016 not only can process the module data from a load cell or a strain gauge, it also features linear mapping that can be used to directly convert the resulting data into weight via a user-defined correspondent table. The I-7016 supports full-bridge strain gauges and provides 2 Analog Input channels, 1 excitation voltage output channel, 2 Digital Input channels and 2 Digital Outpu..
8-channel Current Input Module with Overcurrent Protection using the DCON Protocol. The I-87017RCW is an 8-channel current input module that is specifically designed to measure current only. Its user-friendly design saves both time and effort when measuring a current thanks to a built-in resistor, meaning that current can now be measured directly. The I-87017RCW is much more suitable for critically harsh environments since it also has 4 kV ESD pr..
8-channel True RMS Input Module. The I-87017W-RMS is an 8-channel differential AC input module that is used to convert the AC input signals to their true RMS DC values. The RMS input range can be from +150 mVrms to +10 Vrms, and each channel can be configured individually. The I-87017W-RMS is a complete, high-accuracy, RMS-to-DC converter that computes the true RMS DC value of any complex waveform. It also features 4 kV ESD protection, 3000 VDC i..
10/20-channel Analog Input Module with High Voltage Protection. The I-87017ZW is an analog input module that includes 10 differential or 20 single-ended analog input channels. It provides a programmable input range on all analog inputs. (+/-150 mV, +/-500 mV, +/-1 V, +/-5 V,+/-10 V, +/-20 mA or 0 ~ 20 mA) Each analog input can be configured for an individual range that provides 240 Vrms high overvoltage protection and 50mA overcurrent protection ..
8-channel Analog Input Module using the DCON Protocol with High Voltage Protection. The I-7018/M-7018 is an 8-channel Analog Input module that provides current and voltage input, as well as thermocouple input. The I-7018R/M-7018R is an upgraded version of the I-7018/M-7018 that includes an extremely high-quality protection mechanism where the overvoltage protection can be as high as 240 Vrms. The I-7018R/M-7018R is more suitable for critically ha..
8-channel Thermocouple Input Module. Includes the I-87018PW Module and a CN-1824 Daughter Board. The I-87018PW-G/S is an 8-channel thermocouple input module. The analog input range is software selectable and supports +/-15 mV, +/-100 mV, +/-500 mV, +/-1 V, +/-2.5 V, 0 ~ +20 mA, +4 ~ +20 mA or +/-20 mA, and thermocouples of type J, K, T, E, R, S, B, N, C, L, M, and LDIN43710. It features automatic cold-junction compensation for each channel, and s..