M-Bus Converters for BMS and Automation Systems

M-Bus Converters

This category includes converters with an M-Bus interface. M-Bus is a standard used for reading various types of consumption meters, such as gas meters, water meters, electricity meters, heat meters, and others. The standard consists of a communication protocol and an electrical interface, which is why an additional converter is required to translate the data into an interface/protocol that is understandable to the data collection controller.

M-Bus converters bridge the gap between the world of meters and energy management and building automation systems. Their main task is to convert the signal from the M-Bus bus, which is optimized for meter reading, into standard communication protocols such as Modbus TCP, BACnet, or PROFINET. Thanks to this, data from meters can be easily integrated with BMS (Building Management Systems), SCADA, and other monitoring solutions. This is a crucial step in building smart buildings and factories where energy efficiency and accurate consumption billing are a priority.

What You'll Find Here

We have prepared various types of M-Bus converters for you, depending on the standard you want to use to read the meters. Our offer includes M-Bus converters for: BACnet Ethernet, BACnet MS/TP, DeviceNet, Ethernet, KNX, Modbus RTU, Modbus TCP, PROFIBUS, PROFINET, SNMP, RS-232, RS-485, and USB.

The versatility of our offer allows you to adapt the solution to any infrastructure. M-Bus converters to Modbus TCP and Modbus RTU are ideal for integration with popular PLC controllers. M-Bus to BACnet/IP gateways are standard in advanced BMS systems, enabling central management of utility consumption. Additionally, we offer converters for industrial protocols such as PROFIBUS and PROFINET, which are indispensable for monitoring utility consumption in large manufacturing plants.

Applications and Benefits of M-Bus Converters

Thanks to M-Bus converters, data from meters can be read automatically and sent to a central system, which eliminates the need for manual readings. This is especially useful in large commercial buildings, residential complexes, and industrial facilities. An M-Bus to Modbus TCP converter allows for real-time monitoring of water, gas, or energy consumption, which enables quick detection of leaks or irregularities. This data can then be used to create reports, analyze trends, and optimize consumption.

Our devices are also equipped with advanced features, such as galvanic isolation, which protects sensitive meters and controllers from damage caused by power surges in the network. A solid construction, DIN rail mounting, and a wide operating temperature range from -40°C to 85°C guarantee reliability in the most demanding conditions.

Smart Energy Management

In an era of rising energy prices and increased ecological awareness, M-Bus converters are an essential tool for building smart energy management networks. They enable the implementation of AMR (Automatic Meter Reading) systems, which automate the process of reading, monitoring, and billing consumption. Whether you need to read a dozen meters in a small building or hundreds in a large industrial complex, our converters will ensure stable and efficient communication. The choice of the right converter depends on the number of meters you want to connect (the number of slave units) and the master protocol with which it is to cooperate.

What Problems Do M-Bus Converters Solve?

M-Bus converters are more than just signal conversion devices. They solve a number of key problems faced by building managers, engineers, and network administrators. The first and most obvious is the problem of protocol incompatibility. Utility meters (water, gas, electricity, heat) often communicate exclusively using the M-Bus protocol, which is not understood by most advanced automation systems (e.g., Modbus, BACnet). A converter eliminates this barrier by translating the data into a language that is understandable to the master system.

Another significant problem is manual meter reading. It is not only time-consuming but also prone to human error. In large facilities where meters are located in many hard-to-reach places, automated reading with an M-Bus converter significantly saves time and resources and provides greater data accuracy. This allows for continuous monitoring of consumption, which is invaluable in energy management.

In industrial and commercial environments, there are often electromagnetic interferences and power surges in the power grid. Meters and controllers are sensitive devices that can be damaged. Our M-Bus converters, thanks to built-in galvanic isolation, effectively protect connected devices from such problems, increasing the reliability and safety of the entire installation. Additionally, the wide operating temperature range ensures that the converters operate stably in extreme conditions, from frost to heat.

Last but not least, the problem is the lack of data centralization. Without converters, data from meters is scattered, which makes it difficult to analyze and generate reports. Thanks to a converter, all data is collected at one point and made available to master systems, which enables effective utility management, predictive maintenance, and cost optimization.

For your convenience, we have divided our M-Bus converters according to the technology they support. Choose the one that interests you and see the available converters. You will find them here:

HD67D15-B2-915MHz-40
2 year warranty 3-4 days
Brand: ADF Web Model: HD67D15-B2-915MHz-40
Industrial LoRaWAN to M-Bus converter, up to 40 Slaves, housing type B (wide), DIN rail mounting, LoRaWAN 915MHz antenna protocol.The HD67D15-B2 are M-Bus Master / LoRaWAN Converters.They allow to publish (Uplink) the data read from the Modbus Slaves into a LoRaWAN Gat..
1,908.20 zł
HD67044-B2-80 - MBus to Modbus TCP converter, 80 meters HD67044-B2-80 - MBus to Modbus TCP converter, 80 meters
Shipping 24h Test for Free! 2 year warranty
Brand: ADF Web Model: HD67044-B2-80
Industrial MBus to Modbus TCP converter, master MBus up to 80 slaves, modbus slave port: Ethernet, housing type B (wide), DIN rail mount. The converter for communication with meters uses the MBus, Ethernet connector is used for Modbus TCP communication. The HD67044-B2-8..
1,922.30 zł
MBus to USB converter for up to 80 meters - HD67024-B2-160
2 year warranty 3-4 days
Brand: ADF Web Model: HD67024-B2-160
Industrial MBus to USB converter, master MBus up to 160 slaves, DIN rali mount, housing type B (wide), DIN rail mount. This series allows to read/write MBus Slaves by USB, ensuring galvanic isolation between MBus and USB. HD67024 is a configurable device with logic insi..
1,959.90 zł
Industrial M-Bus to Modbus TCP Gateway for 20 Devices - INMBSMEB0200100
3 year warranty 5-7 days
Brand: Intesis Model: INMBSMEB0200100
INMBSMEB0200100 – Industrial M-Bus to Modbus TCP Gateway for up to 20 Devices. The INMBSMEB0200100 gateway is designed for seamless integration of up to 20 M-Bus meters into any Modbus TCP-based system. Developed by Intesis (HMS Networks), this industrial-gra..
1,988.10 zł
HD67931-B2-G43-40
2 year warranty 3-4 days
Brand: ADF Web Model: HD67931-B2-G43-40
Industrial M-Bus Master to MQTT converter up to 40 Slaves, housing type B (wide), DIN rail mounting. The HD67931-B2-G43-40 model is an industrial converter equipped with a DIN rail mounting function. With an operating temperature range of -40°C to +70°C and IP20 prot..
2,011.60 zł
Industrial M-Bus display and master for up to 60 meters with LCD and keypad – MR004FA
New 5-10 days
Brand: Relay Model: MR004FA
MR004FA – industrial M-Bus display and master for up to 60 meters.MR004FA is an industrial M-Bus display and master designed for remote powering and central read-out of up to 60 M-Bus meters, including heat, water, gas and electricity meters. The device..
2,016.30 zł
HD67031-B2-80
2 year warranty 3-4 days
Brand: ADF Web Model: HD67031-B2-80
Industrial MBus meters analyzer, scanner & sniffer, master MBus up to 80 slaves, housing type B (wide), DIN rail mount. Devices from the series MBus analyzers, scanners allows, among others, on the diagnosis of MBus devices, eavesdropping on bus communication, sendi..
2,063.30 zł
HD67051-B2-40
2 year warranty 3-4 days
Brand: ADF Web Model: HD67051-B2-40
Industrial MBus Master to CANopen Converter, Master MBus up to 40 slaves, housing type B (wide), DIN rail mount. HD67051-B2-40 allow to monitor some MBus meters (like Engelmann, Amber-Wireless, Maddalena, Siemens, exc. meters) with a CANopen net (like a PLC exc). Conver..
2,063.30 zł
HD67053-B2-40 - MBus to PROFIBUS converter, 40 meters HD67053-B2-40 - MBus to PROFIBUS converter, 40 meters
2 year warranty 3-4 days
Brand: ADF Web Model: HD67053-B2-40
Industrial MBus to PROFIBUS converter, master MBus up to 40 slaves, PROFIBUS DP DPV0 support, housing type B (wide), DIN rail mount. HD67053-B2-40 allow to monitor some MBus meters (like Engelmann, Amber-Wireless, Maddalena, Siemens) with a PROFIBUS net (like an SIEMENE..
2,063.30 zł
HD67056-B2-40 HD67056-B2-40
2 year warranty 3-4 days
Brand: ADF Web Model: HD67056-B2-40
Industrial MBus to BACnet Ethernet IP converter with up to 40 MBus slaves, housing type B (wide), DIN rail mount. The converter for communication with meters uses the MBus, Ethernet connector is used for BACnet IP communication. The HD67056-B2-40 converter can read up t..
2,063.30 zł
HD67056-MSTP-40
2 year warranty 3-4 days
Brand: ADF Web Model: HD67056-MSTP-40
Industrial MBus to BACnet MS/TP converter with RS-485 interface with up to 40 MBus slaves. The converter for communication with meters uses the MBus, RS-485 connector is used for BACnet MS/TP communication. The HD67056-MSTP-40 converter can read up to 40 MBus receivers ..
2,063.30 zł
HD67063-485-B2-80
2 year warranty 3-4 days
Brand: ADF Web Model: HD67063-485-B2-80
MBus Multi-Master on Modbus RTU - Converter (Multi-Master MBus: up to 80 slaves - Modbus Slave Port: RS-485), housing type B (wide), DIN rail mount. Configuration:Thanks to the SW67063 software on your PC you can:Define the parameters of MBus lineDefine the parameters o..