What is the Modbus gateway used for?

The Modbus gateway allows rapid integration of devices communicating in Modbus RTU or ASCII protocol with devices communicating in Modbus TCP protocol. The gateway can have from 1 to 8 physical RS-232 or RS-485 communication ports for RTU and ASCII communication and up to 2 Ethernet ports for Modbus TCP communication.

Modbus gateway - product characteristics and features

The devices available in our range are characterised by industrial, energy-efficient design, up to 5-year warranty, resistance to vibration, shock and electromagnetic discharge. Depending on the model, the converters are DIN rail mounted, have galvanic isolation up to 3000V, a wide power supply range of 12-48VDC, 24VAC battery power or power supply via PoE function. The devices' wide operating temperature range of -40°C to 75°C allows the gateways to be installed in environments exposed to frost and the very high temperatures reached in industrial control cabinets. The converters have RS-232 to DB9, power and RS-485 ports on a screw connector and an Ethernet port with RJ45 connector.

The Modbus gateway has several operating modes, including. Modbus RTU/SCII master to Modbus TCP slave mode, where the TCP-side master communicates with slaves on the RTU side, and Modbus RTU/ASCII slave to Modbus TCP master mode, where the RTU-side master communicates with slaves on the TCP side. Selected gateways have a built-in Ethernet switch (2 LAN ports), support up to 256 clients on the Modbus TCP side, up to 240 slaves on the RTU bus, have IP or MAC address filtering capabilities, have SNMP or email alerting and event logging functionality. The MOD-ETH gateway is additionally equipped with digital inputs and outputs manageable from the Modbus TCP master.

Converters are configured using the free software supplied, telnet console or via the built-in web interface.

Choose the Modbus gateway you are interested in and read the detailed technical description of the product.

MOD-ETH MOD-ETH
2-3 days
Brand: Aspar Model: MOD-ETH
Modbus TCP/RTU/ASCII converter - Modbus Gateway with Ethernet interface. MOD-ETH is an innovative device that converts Modbus TCP to Modbus RTU / ASCII.The device has Ethernet and RS485 interface, 4 digital inputs with counters and 3 relay outputs. All inputs are isolated from logic using optocouplers.Up to 128 Modbus I / O Modules (SFAR: SLIM, MINI, STANDARD and other manufacturers) can be connected to the MOD-ETH via the RS485 interface. The da..
592,98 zł
tGW-712 CR tGW-712 CR
2-3 weeks
Brand: ICPDAS Model: tGW-712 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-232 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then ..
631,55 zł
GW1101-1D(RS-485) GW1101-1D(RS-485)
Shipping 24h Test for Free!
Brand: 3onedata Model: GW1101-1D(RS-485)
Industrial Modbus RTU / ASCII gateway to Modbus TCP. Communication ports RS-485/422 and Ethernet, wide temperature range, metal housing IP40.GW1101-1D(RS-485)-TB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; it can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product has 1 RS-485/422 serial port and 1 100M Ethernet copper port. It adopts wall mounting to meet the..
650,84 zł
GW1101-1DI(RS485)
5-10 days
Brand: 3onedata Model: GW1101-1DI(RS485)
Industrial Modbus RTU / ASCII gateway to Modbus TCP. Communication ports 485 and Ethernet 100MGW1101-1D(RS-485)-DB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; they can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product supports 1 RS-485 serial port to 1 100M Ethernet copper port. It adopts wall mounting to meet the requirements of different application scenes..
650,84 zł
tGW-722 CR tGW-722 CR
2-3 weeks
Brand: ICPDAS Model: tGW-722 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 2 RS-232 Ports. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then..
665,30 zł
tGW-712i CR
2-3 weeks
Brand: ICPDAS Model: tGW-712i CR
Industrial Isolated Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-232 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and ..
674,94 zł
tGW-732 CR tGW-732 CR
2-3 weeks
Brand: ICPDAS Model: tGW-732 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 3 RS-232 Ports. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then..
694,22 zł
GW1101-1DI(3IN1)-DB-P(12-48VDC) GW1101-1DI(3IN1)-DB-P(12-48VDC)
5-10 days
Brand: 3onedata Model: GW1101-1DI(3IN1)-DB-P(12-48VDC)
Industrial Modbus RTU / ASCII gateway to Modbus TCP. Communication ports RS-232/485/422 and Ethernet 100MGW1101-1DI(3IN1)-DB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; they can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product supports 1 3IN1 DB9 serial port to 1 100M Ethernet copper port. It adopts wall mounting to meet the requirements of different applic..
703,87 zł
tGW-724 CR tGW-724 CR
2-3 weeks
Brand: ICPDAS Model: tGW-724 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE, 1 RS-485 Port and 1 RS-232 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application)..
718,33 zł
tGW-718 CR tGW-718 CR
2-3 weeks
Brand: ICPDAS Model: tGW-718 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-232/422/485 Port. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and c..
732,79 zł
tGW-715 CR tGW-715 CR
2-3 weeks
Brand: ICPDAS Model: tGW-715 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE and 1 RS-422/485. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then r..
747,26 zł
tGW-734 CR tGW-734 CR
2-3 weeks
Brand: ICPDAS Model: tGW-734 CR
Industrial Modbus TCP to RTU/ASCII Converter with PoE, 1 RS-485 and 2 RS-232 Ports. The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), an..