5-10 days
IDEM ESL-SS emergency stop switch.
IDEM ESL-SS Standard Duty Emergency Stop Switches have been designed to provide robust emergency stop protection for machines or exposed conveyors, and are suitable for use within virtually all industry sectors.
Features:
- Stainless Steel 316 (IP69K) can be high pressure hosed with detergents at high temperature
- Conformance to ISO13850, EN60947-5-1 and EN60947-5-5
- A special lid safety trip mechanism means that the safety contacts will open if the lid is removed
Specifications:
Standards:
- EN60947-5-1
- EN60947-5-5
- EN62061
- UL508
- ISO13850
- ISO13849-1
Safety Classification and Reliability Data:
- Mechanical Reliability B10d: 1.5 x 106 operations at 100mA load
- ISO13849-1: Up to PLe depending upon system architecture
- EN62061: Up to SIL3 depending upon system architecture
- Safety Data – Annual Usage: 8 cycles per hour/24 hours per day/365 days
- PFHd: <1.0 x 10-7
- Proof Test Interval (Life): 21 years
- MTTFd: 214 years
- Enclosure/Cover Material: Stainless Steel 316
- IP Rating: IP67; IP69K
- Mounting: 4 x M4
- Mounting Position: Any
- Conduit Entries: 3 x M20 or 3 x 1/2” NPT
- Tongue Settings:
- Mounting M4 4.0Nm
- Lid T20 Torx M4 1.5Nm
- Terminals 1.0Nm
- Ambient Temperature: -25°C ~ 80°C
- Vibration Resistance: 10-500Hz 0.35mm
- Shock Resistance: 11ms 15g
- Weight: 1060g to 1190g
- Contact Type:
- EN60947-5-1 double break type Zb
- Snap Action up to 4NC (positive break); 2NO (Auxiliary)
- Contact Material: Silver
- Termination: Clamp up to 2.5mm2 conductors
- Rating: Utilisation category AC15
- Operational Rating: 240V 3A
- Thermal Current (lth): 10A
- Rated Insulation Voltage (U): 500V
- Withstand Voltage (Uimp): 2500V
- Short Circuit Overload Protection: Fuse externally 10A(FF)
Warranty: 36 months
Ordering Information:
- ESL-SS 232001 - Conduit Entry: M20; Contacts: 2NC, 2NO
- ESL-SS 232002 - Conduit Entry: 1/2" NPT; Contacts: 2NC, 2NO
- ESL-SS 232003 - Conduit Entry: M20; Contacts: 3NC, 1NO
- ESL-SS 232004 - Conduit Entry: 1/2" NPT; Contacts: 3NC, 1NO
- ESL-SS 232005 - Conduit Entry: M20; Contacts: 4NC
- ESL-SS 232006 - Conduit Entry: 1/2" NPT; Contacts: 4NC
- ESL-SS 232002-GC - Conduit Entry: ½NPT Contacts: '2NC 2NO' with Gold Contacts
- ESL-SS 232003-GC - Conduit Entry: M20 Contacts: '3NC 1NO' with Gold Contacts
- ESL-SS-Ex 232007 - Conduit Entry: 3M Contacts: '1NC 1NO', Ex model
- ESL-SS-Ex 232008 - Conduit Entry: 3M Contacts: '2NC', Ex model
Industrial grade | |
Casing | Metal |
IP rating | IP69K, IP67 |
Operating temperature | -25°C to 80°C |
Input voltage | 240VAC |
Manufacturer's warranty | 36 months |