5-10 days
Coded Non Contact IDEM HYGIECODE RMC.
The cylindrical body of the RMC has Coded Magnetic Actuation and a switching tolerance of up to 10mm. Specified to 105°C - although the RMC has been designed to work up to 125°C. Operating with most Safety Relays the RMC can achieve PLe/Cat4 ISO13849-1.
The cylindrical fitting of the RMC makes it suitable for all industry applications, particularly those found within the food processing and packaging industries. The RMC with its M30 threaded body is easy to install and easy to set.
Specifications:
Standards:
- ISO14119
- EN60947-5-1
- EN60204-1
- ISO13849-1
- EN62061
- UL508
Safety Classification and Reliability Data:
- ISO13849-1: Up to PLe Category 4
- EN62061: Up to SIL3
- PFHd: 8.71 x 10-11
- Proof Test Interval (Life): 20 years
- MTTFd: 866 years
- Safety Channel 1 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 2 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 3 NO: 24Vdc 0.2A Max. Rating
- Minimum Switched Current: 10Vdc 1mA
- Dielectric Withstand: 250Vac
- Insulation Resistance: 100 Mohms
- Recommended Setting Gap: 5mm
- Switching Distance: Sao 10mm Close
- Switching Distance (Target to Target): Sar 20mm Open
- Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
- Switching Frequency: 1.0Hz maximum
- Approach Speed: 200mm/min to 1000mm/sec
- Body Material: Stainless Steel 316 mirror polished finish to Ra4
- Operating Temperature: -25°C ~ 105°C (CIP SIP cleaning)
- Enclosure Protection: IP67; IP69K
- Shock Resistance: IEC68-2-27; 11ms; 30g
- Vibration Resistance: IEC 68-2-6; 10-55Hz; 1mm
- Cable Type: PVC 6 or 8 core 6mm OD; Conductors 0.25mm2
- Mounting Bolts: 2xM4 Tightening torque 1.0Nm
- Mounting Position: Any
Warranty: 36 months
Ordering Information:
- Hygiecode RMC 134001 - Cable Length: 2M; Circuits: 2NC
- Hygiecode RMC 134002 - Cable Length: 5M; Circuits: 2NC
- Hygiecode RMC 134003 - Cable Length: 10M; Circuits: 2NC
- Hygiecode RMC 134004 - Cable Length: QC-M12; Circuits: 2NC
- Hygiecode RMC 134005 - Cable Length: 2M; Circuits: 2NC, 1NO
- Hygiecode RMC 134006 - Cable Length: 5M; Circuits: 2NC, 1NO
- Hygiecode RMC 134007 - Cable Length: 10M; Circuits: 2NC, 1NO
- Hygiecode RMC 134008 - Cable Length: QC-M12; Circuits: 2NC, 1NO
- Hygiecode RMC 134105 - Cable Length: 2M; Circuits: 3NC
- Hygiecode RMC 134106 - Cable Length: 5M; Circuits: 3NC
- Hygiecode RMC 134107 - Cable Length: 10M; Circuits: 3NC
- Hygiecode RMC 134108 - Cable Length: QC-M12; Circuits: 3NC
Industrial grade | |
Casing | Metal |
IP rating | IP67, IP69K |
Operating temperature | -25°C to 105°C |
Input voltage | 24VDC |
Manufacturer's warranty | 36 months |
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!