5-10 days
Magnetic Non Contact IDEM HYGIEMAG CMR-F.
Magnetic Actuation - Power Series. Medium Duty Version 1A or Heavy Duty Version 230VAC/24VDC 2A. Switching tolerance up to 12mm.
Features:
- Specified to 105°C but designed to work up to 125°C.
- Will operate with most Safety Relays.
- Specifically designed for Food Processing applications.
- The mounting holes at the rear to give no Food Traps.
- Stainless Steel 316 Mirror Polished Finish (Ra4) enclosure.
- Suitable for CIP SIP cleaning, Food Splash Zones in accordance with EHEDG guidelines.
- Can be high pressure hosed with detergent at high temperature, rated IP69K.
- Wide sensing at 12mm and high tolerance to misalignment.
- Slim 20mm wide housing allowing fitting into narrow channels.
Specifications:
Standards:
- ISO14119
- EN60947-5-1
- EN60204-1
- ISO13849-1
- EN62061
- UL508
Safety Classification and Reliability Data:
- Mechanical Reliability B10d: 3.3 x 106 operations at 100mA load
- ISO13849-1: Up to PLe depending upon system architecture
- EN62061: Up to SIL3 depending upon system architecture
- Safety Data – Annual Usage: 8 cycles per hour/24 hours per day/365 days
- PFHd: 2.52 x 10-8
- Proof Test Interval (Life): 47 years
- MTTFd: 470 years
- Heavy Duty:
- Safety Channel 1 NC: Voltage Free: 250Vac 2A Max. Rating
- Safety Channel 2 NC: Voltage Free: 250Vac 2A Max. Rating
- Safety Channel 3 NO: Voltage Free: 24Vdc 0.2A Max. Rating
- Fuse: Internal 2.0A (F); External 1.6A (F) (User)
- Medium Duty:
- Safety Channel 1 NC: Voltage Free: 250Vac 1A Max. Rating
- Safety Channel 2 NC: Voltage Free: 250Vac 1A Max. Rating
- Safety Channel 3 NO: Voltage Free: 24Vdc 0.2A Max. Rating
- Fuse: Internal 1.0A (F); External 0.8A (F) (User)
- Contact Release Time: <2ms
- Initial Contact Resistance: <500 milliohm
- Minimum Switched Current: 10Vdc 1mA
- Dielectric Withstand: 250Vac
- Insulation Resistance: 100 Mohms
- Recommended Setting Gap: 5mm
- Switching Distance: Sao 10mm Close
- Switching Distance (Target to Target): Sar 22mm Open
- Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
- Switching Frequency: 1.0Hz maximum
- Approach Speed: 200mm/min to 1000mm/sec
- Body Material: Stainless Steel 316 mirror polished finish to Ra4
- Operating Temperature: -25°C ~ 105°C (CIP SIP cleaning)
- Enclosure Protection: IP67 (NEMA 6); IP69K (NEMA PW12)
- Shock Resistance: IEC68-2-27; 11ms; 30g
- Vibration Resistance: IEC 68-2-6; 10-55Hz; 1mm
- Cable Type: PVC 6 core 6mm OD; Conductors 0.25mm2
- Mounting Bolts: 2xM4 Tightening torque 1.0Nm
- Mounting Position: Any
Warranty: 36 months
Ordering Information:
- Hygiemag CMR-F 135017 - Cable Length: 2M; Circuits: 2NC; NC Duty: Medium 1A
- Hygiemag CMR-F 135018 - Cable Length: 5M; Circuits: 2NC; NC Duty: Medium 1A
- Hygiemag CMR-F 135019 - Cable Length: 10M; Circuits: 2NC; NC Duty: Medium 1A
- Hygiemag CMR-F 135020 - Cable Length: QC-M12; Circuits: 2NC; NC Duty: Medium 1A
- Hygiemag CMR-F 135021 - Cable Length: 2M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Hygiemag CMR-F 135022 - Cable Length: 5M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Hygiemag CMR-F 135023 - Cable Length: 10M; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Hygiemag CMR-F 135024 - Cable Length: QC-M12; Circuits: 2NC, 1NO; NC Duty: Medium 1A
- Hygiemag CMR-F 135025 - Cable Length: 2M; Circuits: 1NC; NC Duty: Heavy 2A
- Hygiemag CMR-F 135026 - Cable Length: 5M; Circuits: 1NC; NC Duty: Heavy 2A
- Hygiemag CMR-F 135027 - Cable Length: 10M; Circuits: 1NC; NC Duty: Heavy 2A
- Hygiemag CMR-F 135028 - Cable Length: QC-M12; Circuits: 1NC; NC Duty: Heavy 2A
- Hygiemag CMR-F 135029 - Cable Length: 2M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Hygiemag CMR-F 135030 - Cable Length: 5M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Hygiemag CMR-F 135031 - Cable Length: 10M; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
- Hygiemag CMR-F 135032 - Cable Length: QC-M12; Circuits: 1NC, 1NO; NC Duty: Heavy 2A
Industrial grade | |
Casing | Metal |
IP rating | IP67, IP69K |
Operating temperature | -25°C to 105°C |
Input voltage | 230VAC, 24VDC |
Manufacturer's warranty | 36 months |
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!