Menu
Your Cart

INBACSAM008O000 – bidirectional Samsung NASA VRF to BACnet IP/MS/TP gateway, offering full HVAC control, monitoring and diagnostics for up to 8 indoor units.

INBACSAM008O000 is INBACSAM008O000 – Samsung NASA VRF to BACnet IP/MS/TP Gateway for 8 Indoor Units.

Samsung to BACnet IP & MS/TP Gateway – Model INBACSAM008O000 for HVAC Integration | Intesis by HMS
5-7 days
INBACSAM008O000 – bidirectional Samsung NASA VRF to BACnet IP/MS/TP gateway, offering full HVAC control, monitoring and diagnostics for up to 8 indoor units.
  • Stock: 5-7 days
  • Model: INBACSAM008O000
0,00 zł
A proven choice for industrial installations.
Ask for compatibility and model selection.
Additional discounts for registered customers.

Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports

If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.

  • Device User Manual
  • CE Declaration of Conformity (EU Declaration of Conformity)
  • Mechanical DrawingsCAD (STEP/DWG) or high-quality PDF
  • Additional Certificates and Test Reports (if available for the model)
Request a package: User manual, CE declaration, CAD, PDF, certificates, test reports

INBACSAM008O000 – Samsung NASA VRF to BACnet IP/MS/TP Gateway for 8 Indoor Units. 

The newer version of this device is IN770AIR00SO000

The INBACSAM008O000 Intesis Gateway delivers seamless, bidirectional communication between Samsung NASA VRF systems and any automation platform that speaks BACnet IP or MS/TP. Designed for integrators who need reliable control of small to mid-sized VRF installations, it exposes every essential HVAC datapoint to a BMS, SCADA or PLC, unlocking energy-optimised set-points, fault reporting and remote maintenance from a single supervisory screen.

Connected directly to the outdoor-unit communication bus, the gateway supervises up to eight indoor units without disturbing native Samsung networking. Beyond start/stop and set-temperature commands, it reveals advanced diagnostics such as compressor status, discharge temperature, error codes and fan feedback, enabling predictive maintenance and rapid troubleshooting. Each value is mapped to standard BACnet objects, so integrators can drop the device into existing building projects with zero scripting.

Commissioning is handled by Intesis MAPS, an intuitive PC tool that auto-discovers indoor units, builds point lists and pushes configurations over USB or Ethernet in minutes. MAPS offers bulk-edit wizards, live packet capture and health dashboards, so engineers can validate networks before hand-over. Once on-line, the gateway’s non-volatile memory stores alarms and running hours, while dual power options (9–36 V DC or 24 V AC) give flexibility on site. A rugged, DIN-rail enclosure with UL-94 V-0 plastic keeps electronics safe in control cabinets, and LEDs on both serial ports simplify on-site diagnostics.

Specification

Ports:
  • Port A
    • 1 × Samsung NASA screw terminal (2-pole) R1/R2 – 1500 V DC isolation
    • 1 × Green 2-pole terminal – reserved
  • Switch A – DIP-switch (future use, default OFF)
  • Port B
    • 1 × EIA-232 SUB-D9 (male) – reserved
    • 1 × EIA-485 3-pole terminal (A, B, SGND) – 1500 V DC isolation
  • Switch B – DIP for EIA-485 (termination & polarisation)
  • Ethernet – 1 × RJ45 10/100 Mb/s
Power:
  • 3-pole screw terminal
  • Input: 9–36 V DC (max 140 mA) or 24 V AC ±10 % (max 127 mA)
LED Indicators:
  • Run / Error
  • Ethernet Link / Speed
  • Port A TX/RX, Port B TX/RX
  • Button A / Button B status
Mechanical:
  • UL 94 V-0 PC plastic, RAL 7035
  • Dimensions (W×H×D): 90 × 88 × 56 mm
  • Protection: IP20 (IEC 60529)
  • Mounting: Wall or DIN-rail EN 60715 TH35
Environmental:
  • Operating temperature: 0 °C – 60 °C
  • Humidity: 5 % – 95 %, non-condensing
Warranty: 36 months