40W Single Output Industrial DIN Rail Power Supply.

DIN rail mounted power supply unit with 24VDC output voltage, 40W power, 1.7A output current and fanless cooling.

Features:

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Class I, Div 2 Hazardous Locations T4
  • DC OK relay contact
  • 100% full load burn-in test
  • No load power consumption < 0.75W

Specification:

Power supply

  • Output:
    • DC Voltage: 24V
    • Rated Current: 1.7A
    • Current Range: 0 ~ 1.7A
    • Rated Power: 40.8W
    • Ripple & Noise (max.): 150mVp-p
    • Voltage Adj. Range: 24 ~ 30V
    • Voltage tolerance: +/- 1.0%
    • Line Regulation: +/- 1.0%
    • Load Regulation: +/- 1.0%
    • Setup, Rise Time: 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load
    • Hold up time (typical): 50ms/230VAC; 20ms/115VAC at full load
  • Input:
    • Voltage Range: 85 ~ 264VAC; 120 ~ 370VDC
    • Frequency range: 47 ~ 63Hz
    • Efficiency (typical): 88%
    • AC Current (typical): 1.1A/115VAC; 0.7A/230VAC
    • In Rush Current (typical): Cold Start 30A/115VAC; 60A/230VAC
    • Leakage Current: <1mA / 240VAC

Protection

  • Overload: 105 ~ 150% rated output power
  • Protection type: Constant current limiting, recovers automatically after fault condition is removed
  • Over Voltage: 31.2 ~ 36V
  • Protection type: Shut down o/p voltage, re-power on to recover

Function

  • DC OK Active Signal: Relay contact rating (max.): 30V/1A resistive

Safety & EMC

  • Safety Standards: UL508, TUV EN60950-1, TUV EN60950-1, Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 approved
  • Withstand Voltage: I/P-O/P:3KVAC; I/P-FG:2KVAC; O/P-FG:0.5KVAC
  • Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25°C/70% RH
  • EMC Emission: Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
  • EMC Immunity: Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A

Environmental Characteristics

  • MTBF: 301.700 h
  • Weight: 0,3 kg
  • Dimensions (W x D x H): 22.5mm x 90mm x 100mm
  • Operation Temperature: -20°C ~ 70°C (Refer to output load derating curve)
  • Storage Temperature: -40°C ~ 85°C
  • Humidity: 20% to 90% while working; 10% to 95% storage
  • Vibration: Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

Warranty: 36 months

ORDERING INFORMATION: MDR-40-24


General technical parameters
Power 40W
Output current 1.7A
Output voltage 24VDC
Industrial grade
Operating temperature -20°C to 70°C
Input voltage 85~264VAC, 120~370VDC
Manufacturer's warranty 36 months