5-10 days
Coded Non Contact IDEM HYGIECODE SMC-F.
A member of the HYGIECODE family of switches the SMC-F has a CODED MAGNETIC Actuation and a SWITCHING TOLERANCE of up to 14mm. Specified to 105°C the SMC-F has been designed to work up to 125°C.
The robust Stainless Steel 316 Mirror Polished Finish (Ra4) enclosure has been specifically designed for Food Processing applications. Suitable for CIP SIP cleaning - mounting holes are at the rear - thereby creating no food traps.
Specifications:
Standards:
- ISO14119
- EN60947-5-1
- EN60204-1
- ISO13849-1
- EN62061
- UL508
Safety Classification and Reliability Data:
- ISO13849-1: Up to PLe Category 4
- EN62061: Up to SIL3
- PFHd: 8.71 x 10-11
- Proof Test Interval (Life): 20 years
- MTTFd: 866 years
- Safety Channel 1 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 2 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 3 NO: 24Vdc 0.2A Max. Rating
- Minimum Switched Current: 10Vdc 1mA
- Dielectric Withstand: 250Vac
- Insulation Resistance: 100 Mohms
- Recommended Setting Gap: 5mm
- Switching Distance: Sao 10mm Close
- Switching Distance (Target to Target): Sar 20mm Open
- Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
- Switching Frequency: 1.0Hz maximum
- Approach Speed: 200mm/min to 1000mm/sec
- Body Material: Stainless Steel 316 mirror polished finish to Ra4
- Operating Temperature: -25°C ~ 105°C
- Enclosure Protection: IP67; IP69K
- Shock Resistance: IEC68-2-27; 11ms; 30g
- Vibration Resistance: IEC 68-2-6; 10-55Hz; 1mm
- Cable Type: PVC 6 or 8 core 6mm OD; Conductors 0.25mm2
- Mounting Bolts: 2xM4 Tightening torque 1.0Nm
- Mounting Position: Any
Warranty: 36 months
Ordering Information:
- Hygiecode SMC-F 137001 - Cable Length: 2M; Circuits: 2NC
- Hygiecode SMC-F 137002 - Cable Length: 5M; Circuits: 2NC
- Hygiecode SMC-F 137003 - Cable Length: 10M; Circuits: 2NC
- Hygiecode SMC-F 137004 - Cable Length: QC-M12; Circuits: 2NC
- Hygiecode SMC-F 137005 - Cable Length: 2M; Circuits: 2NC, 1NO
- Hygiecode SMC-F 137006 - Cable Length: 5M; Circuits: 2NC, 1NO
- Hygiecode SMC-F 137007 - Cable Length: 10M; Circuits: 2NC, 1NO
- Hygiecode SMC-F 137008 - Cable Length: QC-M12; Circuits: 2NC, 1NO
- Hygiecode SMC-F 137105 - Cable Length: 2M; Circuits: 3NC
- Hygiecode SMC-F 137106 - Cable Length: 5M; Circuits: 3NC
- Hygiecode SMC-F 137107 - Cable Length: 10M; Circuits: 3NC
- Hygiecode SMC-F 137108 - Cable Length: QC-M12; Circuits: 3NC
Industrial grade | |
Casing | Metal |
IP rating | IP67, IP69K |
Operating temperature | -25°C to 105°C |
Input voltage | 24VDC |
Manufacturer's warranty | 36 months |
1
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!