5-10 days
SMC-H: Coded Non Contact HYGIECODE
IDEM’s coded non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO14119. They feature solid state technology, providing a high tolerance to shock, vibration and tampering.The hall effect operation means the contacts are volt free with a switching capability of 0.2A dc. They are suitable for hinged, sliding or removable guard applications and can connect to most safety relays to provide a higher level of functional safety.
Features:- Housing/Fixing: Compact Body, 22mm Fixing Holes
- Material: Mirror Polish (Ra4), 316 stainless steel ideal for exposure to chemical cleaning agents
- Contacts: Up to 3 N/C or 2 N/C + 1 N/O
- Sensing Distance: Wide 14mm operation
- Ingress Protection: IP67 and IP69K
- Operating Temperature: -25C to 105C
- Connection: Pre-Wired or M12 8-pole Quick Connect
Specification:- Switching Frequency 1.0Hz maximum
- PFHd 2.6 x 10-10
- Proof Test Interval (Life) 20 years
- Dielectric Withstand 250Vac
- Insulation Resistance 100 Mohms
- Recommended Setting Gap 5mm
- Switching Distance Sao 10mm Close
- Tolerance to Misalignment 5mm in any direction from 5mm setting gap
- Approach Speed 200mm/min to 1000mm/sec
- Body Material Stainless Steel 316 mirror polished finish to Ra4
- Operating Temperature -25C +105C (CIP SIP cleaning)
- Enclosure Protection IP69K IP67
- Shock Resistance IEC68-2-27 11ms 30g
- Vibration Resistance IEC68-2-6 10-55Hz 1mm
- Cable Type PVC 6 or 8 core 6mm OD Conductors 0.25mm2
- Mounting Bolts 2xM4 Tightening torque 1.0Nm
- Mounting Position Any
Certificates: ISO14119 EN60947-5-1 EN60204-1 ISO13849-1 EN62061 UL508
Warranty: 36 months