Menu
Your Cart

FLAME-X 950 NTKOGsekwf 150/250V (300V)

FLAME-X 950 NTKOGsekwf 150/250V (300V)
To be confirmed
FLAME-X 950 NTKOGsekwf 150/250V (300V)
  • Stock: To be confirmed
  • Brand: TELE-FONIKA Kable
  • Model: FLAME-X 950 NTKOGsekwf 150/250V (300V)
Product Views: 3589
0,00 zł

Halogen-free and fire-proof telecommunication, measuring and signaling ship cables with low smoke emission jointly shielded with aluminum-polyester tape. Compliant with IEC 60092-376.

Construction:

  • Conductors: Circular stranded tinned copper class 5 acc. to IEC 60228
  • Insulation: Special cross-linked compound HF S 95 acc. to IEC 60092-351
  • Inner covering: Lapped with non-hygroscopic tape
  • Collective screen: Of aluminium/polyester tape with the metallic contact with a tinned copper drain wire
  • Sheath: Thermoplastic halogen free polyolefin compound type SHF1 acc. to IEC 60092-359
  • Colour of sheath: Red
  • Pair identification: Black and white

Technical Data:

  • Maximum conductor operating temperature: +90°C
  • Lowest ambient temperature for fixed installation: -40°C
  • Lowest installation temperature: -15°C
  • Minimum bending radius: 6 x D (D is the overall diameter of the cable)
  • Fire resistant: IEC 60331-21
  • Flame retardant: IEC 60332-3-22 Category A
  • Smoke emission: IEC 61034-2
  • Gases evolved during combustion:
    • IEC 60754-1: < 5 mg/g acid gas
    • IEC 60754-2: pH ≥ 4,3; conductivity ≤ 10 μSmm-1
  • Application: Cables are designed for interconnection of all sorts of instrumentation and communication equipment whose proper functioning is necessary for the safety of the ship. This cable type is especially designed for installations on passenger ships
  • Standard length cable packing: 500 or 1000 m on drums. Other forms of packing are available on request

Industrial grade
Operating temperature to 90°C
Cable parameters
Minimum bending radius 6D
Core Copper
Shield Aluminum-polyester foil
Installation temperature -15°C to 90°C
Standard packaging On drums
Coating Thermoplastic halogen-free polyolefin
Filling Tape
Minimum ambient temperature -40°C
Resistance to flame spread IEC 60332-3-22
Fume emission during combustion IEC 61034-2
Outer diameter [mm] 7.8
Cable weight [kg/km] 72

Write a review

Note: HTML is not translated!
Bad Good
We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.