FLAMEBLOCKER H07Z-U/07Z-U 450V/750V, H07Z-R/07Z-R 450/750V
To be confirmed
FLAMEBLOCKER H07Z-U/07Z-U 450V/750V, H07Z-R/07Z-R 450/750V
- Stock: To be confirmed
- Brand: TELE-FONIKA Kable
- Model: FLAMEBLOCKER H07Z-U/07Z-U 450V/750V, H07Z-R/07Z-R 450/750V
0,00 zł
Single core cables for permanent installation, low smoke emission and corrosive gases during smoking.
Application
In electrical engineering, control cabinets, switching stations, automation devices, as well as in lighting equipment and installations, in facilities with stricter fire-fighting requirements. Intended for laying in installation pipes mounted outside or embedded in the ground, or similar closed systems. For permanently protected installations inside or outside of lighting or control devices for alternating voltage up to 1000V or constant voltage up to 750V relative to ground.
Construction:
- Live: Copper, annealed according to EN 60228:
- Class 1 H07Z-U
- Class 2 H07Z-R
- Insulation: Special cross-linked halogen-free blend EI5 type according to EN 50363-5
- Insulation color: green-yellow, blue, black, brown, gray, orange, red, white, (other colors not included in the standard 50525-1, available on request as 07Z-U, -R)
Characteristics:
- Maximum temperature of the core during cable operation: +90°C
- The minimum ambient temperature when laying cables: -5°C
- The minimum ambient temperature for permanently laid cables: -40°C
- Maximum core temperature during short circuit: +250°C
- Voltage test 50Hz: 2500V
- Rated short-term current density for short-circuit time 1 sec: 143 A/mm² (for core temperature at the beginning of a short circuit of 90°C)
Reaction to fire:
- Resistance to flame spread: IEC 60332-1-2, IEC 60332-3-24
- Smoke emission: EN 61034-2
- Separation of corrosive gases during combustion:
- IEC 60754-1: < 0,5% HCl
- IEC 60754-2: pH³ ≥ 4,3; conductivity ≤ 10 μSmm-1
- CPR - reaction to fire class (according to EN 50575): Eca; Cca-s2, d0, a1; Dca-s1, d0, a1
Complies with: PN-EN 50525-3-41, BS-EN 50525-3-41
Industrial grade | |
Operating temperature | to 90°C |
Cable parameters | |
Minimum bending radius | 4D, 2D, 5D, 3D, 6D |
Core | Copper |
Insulation | Cross-linked halogen-free compound |
Installation temperature | -5°C to 90°C |
Maximum short circuit temperature | 250°C |
Test voltage | 2.5 kV |
Standard packaging | Discs |
Minimum ambient temperature | -40°C |
Resistance to flame spread | IEC 60332-1-2, IEC 60332-3-24 |
Fume emission during combustion | EN 61034-2 |
Number of wires in the cable | Single-core |
Outer diameter [mm] | 2.8, 3.3, 3.8, 4.3, 5.5, 3.0, 3.6, 4.1, 4.7, 6.0, 7.0, 8.7, 9.8, 11.6, 13.3, 15.6, 17.2, 18.4, 20.3, 23.2, 25.4, 28.5, 32.1, 36.3 |
Cable weight [kg/km] | 19, 30, 45, 63, 105, 21, 32, 47, 67, 111, 168, 263, 356, 478, 674, 932, 1155, 1421, 1774, 2307, 2886, 3729, 4768, 6030 |
1
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!
Tags:
h07z
, 750v
, flameblocker
, 450v
, electroenergetic
, cables
, tele
, fonika
, kable
, FLAMEBLOCKER
, H07Z-U/07Z-U
, 450V/750V
,
, H07Z-R/07Z-R
, 450/750V
, Electroenergetic cables