Menu
Your Cart

FlameBlocker NTKOXSekw IB 150/250V (300V)

FlameBlocker NTKOXSekw IB 150/250V (300V)
To be confirmed
FlameBlocker NTKOXSekw IB 150/250V (300V)
  • Stock: To be confirmed
  • Brand: TELE-FONIKA Kable
  • Model: FlameBlocker NTKOXSekw IB 150/250V (300V)
Product Views: 3720
0,00 zł

Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, multi-core or multi-pair (triple), jointly shielded with copper wires (with extruded internal IB filling).

Construction:

  • Conductors: Circular stranded bare or tinned copper class 2 or class 5 acc. to IEC 60228
  • Insulation: Cross-linked polyethylene HF-XLPE 90ºC acc. to IEC 60092-351
  • Inner covering: Lapped with non-hygroscopic tape
  • Armour (screen): Copper wire braiding with the metallic contact with a copper drain wire (optional)
  • Sheath: Thermoplastic halogen free polyolefin compound type SHF1 acc. to IEC 60092-359
  • Colour of sheath: Blue
  • Core identification: White with black printed numbers
  • Pair identification:
    • core a: blue (or black)
    • core b: white
    • with printed pair number
  • Triple identification:
    • core a: blue
    • core b: white
    • core c: red
    • with printed triple number

Technical Data:

  • Maximum conductor operating temperature: +90°C
  • Lowest ambient temperature for fixed installation: -40°C
  • Lowest installation temperature: -15°C
  • Maximum short-circuit conductor temperature: +250°C
  • Minimum bending radius: 6 x D (D is the overall diameter of the cable)
  • Flame retardant: IEC 60332-3-22 Category A
  • Smoke emission: IEC 61034-2
  • Gases evolved during combustion:
    • IEC 60754-1: < 5 mg/g acid gas
    • IEC 60754-2: pH ≥ 4,3; conductivity ≤ 10 μSmm-1
  • Application: Cables are designed for interconnection of all sorts of instrumentation and communication equipment including that telephone equipment whose proper functioning is necessary for the safety of the ship
  • Standard length cable packing: 500 or 1000 m on drums. Other forms of packing are available on request
  • Approvals: GL, DNV, LR, RINA, CLASSNK, BV
  • Standard: IEC 60092-376

Industrial grade
Operating temperature to 90°C
Cable parameters
Minimum bending radius 6D
Core Copper
Shield Copper wires
Insulation Polyethylene
Installation temperature -15°C to 90°C
Maximum short circuit temperature 250°C
Standard packaging On drums
Coating Thermoplastic halogen-free polyolefin
Filling Extruded IB
Minimum ambient temperature -40°C
Resistance to flame spread IEC 60332-3-22
Fume emission during combustion IEC 61034-2
Number of wires in the cable Multi-core
Outer diameter [mm] 8.6, 9.5, 11.4, 12.4, 14.0, 17.7, 18.1, 18.8, 20.7, 23.7, 26.7, 9.1, 12.5, 15.9, 19.8, 9.6, 10.5, 13.0, 13.9, 16.6, 18.3, 20.4, 21.0, 21.9, 23.1, 24.1, 25.2, 27.8, 31.6, 9.9, 14.8, 23.3, 10.9, 13.7, 15.3, 21.6, 22.2, 23.2, 25.6, 29.7, 33.7, 10.3, 15.5, 19.3, 24.7, 12.3, 16.0, 17.4, 20.3, 22.3, 25.0, 25.8, 27.1, 28.4, 30.0, 31.5, 35.4, 40.8, 15.8, 19.0, 24.8, 28.9, 32.0, 13.3
Cable weight [kg/km] 119, 142, 184, 219, 284, 435, 466, 501, 611, 737, 958, 130, 230, 394, 578, 173, 235, 271, 405, 468, 559, 604, 654, 732, 801, 857, 978, 1296, 157, 323, 514, 769, 160, 196, 269, 356, 483, 632, 706, 768, 953, 1176, 1550, 377, 586, 914, 192, 247, 380, 455, 626, 705, 852, 935, 1036, 1151, 1290, 1341, 1623, 2290, 211, 334, 485, 552, 793, 922, 1234, 1507, 306

Write a review

Note: HTML is not translated!
Bad Good
We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.