GW1101-1DI(RS485)
5-10 days
GW1101-1DI(RS485)
- Stock: 5-10 days
- Brand: 3onedata
- Model: GW1101-1DI(RS485)
641,25 zł
Available Options
Industrial Modbus RTU / ASCII gateway to Modbus TCP. Communication ports 485 and Ethernet 100M
GW1101-1D(RS-485)-DB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; they can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product supports 1 RS-485 serial port to 1 100M Ethernet copper port. It adopts wall mounting to meet the requirements of different application scenes. Modbus gateway supports multiple network protocols, such as Modbus, TCP, IP, UDP, TELNET, ARP, ICMP, HTTP, HTTPS, SNMP, SSH,SMTP, SNTP,DNS and DHCP protocols. It possesses complete management function, and supports access control, rapid configuration, online upgrading, etc. RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes are supported; it supports up to 256 Modbus TCP client (master) accesses and connects up to 128 Modbus TCP server (slave) devices. TELNET, WEB, SSHD and other access modes are also supported. It can provide users with good experience with friendly design of network management system interface, simple and convenient operation.
DIP switch can achieve restore factory defaults of the device. Hardware adopts fanless, low power consumption, wide temperature and voltage design and has passed rigorous industrial standard tests, which can suit for the industrial scene environment with harsh requirements for EMC. It can be widely used in PLC control and management, Building Automation System, Health Care Automation System, measuring instrument and environmental forces monitoring system, etc.
Features:
- Support 1 RS-485 serial port and 1 10/100Base-T(X) self-adaptive Ethernet interface
- Support conversion between Modbus RTU/ASCII and Modbus TCP protocol
- Support RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes
- Support virtual and real ID mapping to achieve flexible access between Master and Slave devices
- Support 12~48VDC power supply input
- Support -40~75°C wide operating temperature range
Specification:
Ethernet
- Standards: 10Base-T, 100Base-TX
- Protocol: Modbus TCP, TCP, IP, UDP, ARP, HTTP, TELNET, SNMP, ICMP, DHCP, DNS
- Rate: 10/100M Automatic Flow Control, MDI/MDI-X Autotunning
- Interface quantity: 1
- Interface form: RJ45
- Duplex mode: Full/Half Duplex Mode Self-adaption
Serial port
- Standard: EIA RS-485
- Protocol: Modbus RTU/ASCII
- Quantity of serial port: 1 RS-485 serial port
- RS-232 signal: DSR, RTS, GND, TXD, RXD,CTS, DTR
- RS-485 signal: D+, D-, GND
- RS-422 signal: T+, T-, GND, R+, R-
- Baud rate: 110-115200bps
- Data bit: 7bit, 8bit
- Stop bits: 1bit, 2bit
- Parity bit: None, Even, Odd, Space, Mark
- Stop bit: 1bit, 2bit
- Interface form: DB9
- Flow control: RTS/CTS, DTR/DSR, XON/XOFF
- Directional control: RS-485 direction adopts Automatic Data Direction Control technology
- Pull high/low resistor for RS-485: 4.7kΩ
- Electromagnetic isolation strength: 3KVDC/2KVrms
- Operating mode: RTU Master, RTU Slave, ASCII Master and ASCII Slave
- Connection quantity: support up to 256 Modbus TCP client (master) accesses and connect up to 128 Modbus TCP server (slave) devices.
Configuration Method
- WEB configuration management, TELNET configuration, Windows configuration tool, SSHD configuration
Security
- User right classification, IP address filtering, MAC address filtering, SNMP/ Mail /System Log alarm, HTTP/HTTPS/SSHD/TELNET access control
Indicator
- Power supply indicator, running indicator, Ethernet port indicator, serial port indicator
Power Supply
- 12~48VDC, 3-pin 5.08mm pitch terminal blocks
- Power supply nonpolarity
Power Consumption
- No-load: 0.9W@12VDC
- Full-load: 1.1W@12VDC
Working Environment
- Operating temperature: -40°C ~ 75°C
- Storage temperature: -40°C ~ 85°C
- Humidity: 5% ~ 95% (no condensation)
Physical Characteristic
- Housing: IP40 protection, metal
- Installation: wall mounting
- Dimension (W x H x D): 97mm×110mm×25mm
- Weight: 297g
Industrial Standard:
IEC 61000-4-2 (ESD, electrostatic discharge), Level 4
- Air discharge: ±15kV
- Contact discharge: ±8kV
IEC 61000-4-4 (EFT, electrical fast transient pulses), Level 3
- Power supply: ±2kV
- Signal: ±1kV
IEC 61000-4-5 (Surge), Level 3
- Power supply: common mode±2kV, differential mode±1kV
- Signal: common mode ±1kV, differential mode ±1kV
- Shock: IEC 60068-2-27
- Free fall: IEC 60068-2-32
- Vibration: IEC 60068-2-6
Authentication: CE, FCC, RoHS
Warranty: 5 years
General technical parameters | |
Ethernet | 1x 10/100BaseT(X) |
Serial port | 1x RS-485 |
Industrial grade | |
Casing | Metal |
IP rating | IP40 |
Operating temperature | -40°C to 75°C |
Input voltage | 12~48VDC |
Certificates & standards | CE, FCC, RoHS |
Manufacturer's warranty | 3 years |
Mount | Wall mount |
1