NSGAFÖU 0.6/1 kV, 1.8/3 kV i 3.6/6 kV

NSGAFÖU 0.6/1 kV, 1.8/3 kV i 3.6/6 kV
To be confirmed
NSGAFÖU 0.6/1 kV, 1.8/3 kV i 3.6/6 kV
  • Stock: To be confirmed
  • Brand: TELE-FONIKA Kable
  • Model: NSGAFÖU 0.6/1 kV, 1.8/3 kV i 3.6/6 kV
0,00 zł

Special single-core cables in rubber insulation.

The cables are intended for permanent installation in rail vehicles, in pipes and closed ducts. 1.8 / 3 kV cables can be used in control devices and distributors up to 1000V. In power and connection systems, this type of cable gives high resistance to short-circuit and earth-fault overloads.

Construction:

  • Cores: Of tinned copper wires, multi-wire flexible classes 5 according to DIN-EN 60228
  • Insulation: EPR rubber compound type 3GI3 according to DIN VDE 0207 part 20
  • Insulation color: Natural
  • Outer coverage: 5GM3 flame retardant and oil resistant compound according to DIN VDE 0207 part 21
  • The color of the outer cover: Black

Characteristics:

  • Maximum conductor temperature during cable operation: +90°C
  • Minimum ambient temperature for permanently laid cables: -40°C
  • Minimum ambient temperature for cable laying: -25°C
  • Maximum core temperature during short circuit: +250°C
  • Minimum bending radius: 5x outer diameter of the wire
  • Standard packaging: On drums of 500 or 1000 m. It is possible to offer other lengths of sections and types of packaging.

Reaction to fire:

  • Resistance to flame spread: IEC 60332-1-2
  • CPR - reaction to fire class (according to EN 50575): Eca

Complies with: DIN VDE 0250-602


Industrial grade
Operating temperature to 90°C
Cable parameters
Minimum bending radius 5D
Core Copper
Insulation Ethylene-propylene rubber (EPR)
Installation temperature -25°C to 90°C
Outer coating Rubber compound
Maximum short circuit temperature 250°C
Standard packaging On drums
Minimum ambient temperature -40°C
Resistance to flame spread IEC 60332-1-2
Number of wires in the cable Single-core
Outer diameter [mm] 4.7, 5.4, 5.7, 6.1, 6.2, 6.6, 6.7, 7.2, 8.0, 8.1, 8.7, 8.8, 9.2, 9.8, 10.8, 11.5, 11.9, 12.0, 12.7, 14.3, 14.5, 14.7, 16.1, 16.5, 18.0, 18.6, 19.4, 19.7, 20.5, 21.9, 22.0, 22.7, 24.0, 24.5, 25.0, 25.3, 25.4, 26.9, 27.3, 30.9, 31.3, 34.4, 39.7
Cable weight [kg/km] 35, 47, 50, 60, 68, 74, 76, 84, 89, 98, 99, 139, 151, 170, 199, 212, 282, 292, 324, 396, 400, 418, 558, 571, 600, 740, 754, 769, 861, 986, 1020, 1106, 1219, 1255, 1335, 1514, 1555, 1676, 1865, 1887, 1953, 2404, 2429, 3007, 3035, 3849, 3853, 4972
Working conductor cross section [mm2] 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0, 240.0, 300.0, 400.0, 500.0