Menu
Your Cart

OnGcrekgż-G (Z) 3.6/6 kV

OnGcrekgż-G (Z) 3.6/6 kV
To be confirmed
OnGcrekgż-G (Z) 3.6/6 kV
0,00 zł
A proven choice for industrial installations.
Ask for compatibility and model selection.
Register and get cheaper offers today.

Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports

If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.

  • Device User Manual
  • CE Declaration of Conformity (EU Declaration of Conformity)
  • Mechanical DrawingsCAD (STEP/DWG) or high-quality PDF
  • Additional Certificates (if available for the model)
  • Test Reports (if available for the model)
Request a package: User manual, CE declaration, CAD, PDF, certificates, test reports

Minerals shielded for rated voltage 3.6 / 6 kV.

Construction:

  • Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228
  • Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989
  • Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989
  • The color of the insulation of the veins: Natural
  • Screen on the insulation of working cores: GP semiconductor rubber according to PN-E 29100: 1989
  • Tire inner layer: Of rubber type ON-4 according to PN-E-29100: 1989. In the case of a double-layer tire, ext. made of rubber IZ or IEP, external rubber ON-4
  • Strengthening braid: Made of polyamide yarn
  • Tire outer layer: Of rubber type ON-4 according to PN-E-29100: 1989
  • Tire color: Red or black

Characteristic:

  • Application: For powering mining open-cast mining machines, for work in continuous coiling and unwinding conditions
  • Explanation of the conductor symbol: OnGcrekgż-G (Z) - power cable with tinned copper conductors, heat-resistant rubber insulated, reduced (Gcr) and flame-retardant proud (On), with shielded conductors semi-conductive rubber (ekgż), mining (-G ), for winding and developing ((Z))
  • Example of cable marking: OnGcrekgż-G (Z) four-wire conductor for 3.6 / 6 kV voltage with a section of 70 mm2 working wires, 35 mm2 protective conductor: OnGcrekgż-G (Z) 3x70 + 3x35 / 3 mm2 3.6 / 6 kV cable according to ZN- 95 / MP-13-K104
  • Maximum core temperature during insulation operation: + 90 °C
  • Working range in the temperature range: -40 °C to + 50 °C
  • Minimum bending radius: 12 x D, D - outer diameter of the wire
  • Assay voltage: 11 kV working veins
  • Packing: Cable drums

Compliant with: ZN-95 / MP-13-K 104


Industrial grade
Operating temperature-40°C to 50°C, -40°C to 90°C
Cable parameters
Minimum bending radius12D
CoreCopper
ShieldSemi-conductive rubber
InsulationHeat-resistant rubber
Maximum allowable tensile stresses0.45 kN, 0.72 kN, 1.125 kN, 1.575 kN, 2.25 kN, 3.15 kN, 4.275 kN, 5.4 kN, 6.75 kN, 8.325 kN
Test voltage11 kV
Standard packagingOn drums
TireRubber
Outer diameter [mm]32.9, 35.4, 37.9, 40.7, 45.0, 48.9, 54.8, 57.1, 62.6, 67.3
Cable weight [kg/km]1525, 1875, 2275, 2750, 3525, 4350, 5575, 6650, 7975, 9450
Working conductor cross section [mm2]10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0

Write a review

Note: HTML is not translated!
Bad Good
1