OnZGcekż-GW (A) 0.6/1 kV
To be confirmed
OnZGcekż-GW (A) 0.6/1 kV
- Stock: To be confirmed
- Brand: TELE-FONIKA Kable
- Model: OnZGcekż-GW (A) 0.6/1 kV
0,00 zł
Power cables for mobile and portable receivers. Mining wires shielded for rated voltage 0.6 / 1 kV.
Construction:
- Working, protective and auxiliary veins: Copper tinned multi-wire class 5 acc. PN-EN 60228
- Separator: On operating wires made of polyester film
- Insulation: IEP heat-resistant rubber according to PN-89 / E-29100
- Screen on the working veins and on the sheath of the auxiliary veins: In the form of a roll with a conductive band and a braid of tinned copper wires of 0.30 mm diameter and plastic yarn with a coverage density of at least 30%
- Coating on the center of auxiliary veins: IZ or IEP rubber according to PN-89 / E-29100
- Inserts: Made of vulcanised rubber
- Color of insulation:
- Working: blue, natural, red
- 3 auxiliary: blue, natural, red
- 6 auxiliary: 2 blue, 2 natural, 2 red
- Outer tire: Of rubber type ON-5 according to PN-E22100: 1989
- Water-blocking tape: On the twisted medium of the hose, a loop of blocking tape with a swelling height of at least 5 mm
- Braid made of aramid cables: At least 18 aramid strands with a minimum breaking force of 2300 N
- Tire: Made of ON-4 type rubber, according to PN-89 / E-29100
- Tire color: Black
Characteristic:
- Application: For powering mine underground equipment, the cable can be installed without the use of a cable picker
- Explanation of the conductor symbol: power cable with copper conductors, heat-resistant rubber insulation (Gc) and flame retardant rubber (On), reinforced with a steel wire braid (OnZ) or aramid wires (A) with shielded wires with copper wire (ekż), mining (-G) waterproof (W)
- Example of wire marking: OnZGcekż-GW (A) ten-core cable for 0.6 / 1 kV with a cross section of 70 mm2 conductors, 35 mm2 protective conductor and 4 mm2 auxiliary conductors
- Maximum cable temperature: + 90 °C
- Cable application range: For operation in the temperature range from -30 °C to + 50 °C
- Assay voltage:
- Working veins: 3.2 kV
- Auxiliary veins: 2kV
- Packing: On drums
Compliant with: ZN-96 / MP-13-K1172
Industrial grade | |
Operating temperature | -30°C to 90°C, -30°C to 50°C |
Cable parameters | |
Core | Copper |
Shield | Conductive tape, Copper wires, Plastic yarn |
Insulation | Heat-resistant rubber |
Test voltage | 3.2 kV, 2 kV |
Standard packaging | On drums |
Tire | Rubber |
Number of wires in the cable | Multi-core |
Outer diameter [mm] | 44.1, 46.5, 57.6, 59.9 |
Cable weight [kg/km] | 2710, 3576, 5140, 3000, 3600, 5172, 6418 |
Working conductor cross section [mm2] | 35.0, 50.0, 70.0, 95.0 |
1
We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!