Medium Voltage Cables in XLPE insulation for wind power with copper conductor, multi-strand class 2, burnished, RMC type. Compliant with DIN VDE 0276-620 and HD 620S2:2010 part 10 section C...
High voltage XLPE insulated cables and lead shield. Aluminum working core. Available configurations:NA2X(F)K2Y - 26/45 ÷ 47 (52) kV; according to DIN VDE 0276-632NA2X(F)K2Y - 36/60 ÷ 69 (72.5) kV; according to DIN VDE 0276-632NA2X(F)K2Y - 64/110 ÷ 115 (123) kV; according to DIN VDE 0276-632NA2X(F)K2Y - 76/132 ÷ 138 (145) kV; according to DIN VDE 0276-632NA2X(F)K2Y - 87/150 ÷ 161 (170) kV; according to DIN VDE 0276-632..
High voltage XLPE insulated cables with corrugated aluminum sheath. Aluminum working core. Available configurations:NA2X(F)KLD2Y - 26/45 ÷ 47 (52) kV; according to DIN VDE 0276-632NA2X(F)KLD2Y - 36/60 ÷ 69 (72.5) kV; according to DIN VDE 0276-632NA2X(F)KLD2Y - 64/110 ÷ 115 (123) kV; according to DIN VDE 0276-632NA2X(F)KLD2Y - 76/132 ÷ 138 (145) kV; according to DIN VDE 0276-632NA2X(F)KLD2Y - 87/150 ÷ 161 (170) kV; according to DIN VDE 0276-632..
Power cables with aluminum wires with XLPE insulation and PE coating. Construction:Veins: Multi-round round class 2 according to EN 60228Screen on the veins: Semi-conductive polyethyleneIsolation: Cross-linked polyethyleneScreen on insulation: Semi-conductive polyethyleneSealing: ThrustMetallic screen: Cu wires / Cu bandCoating: PolyethyleneCoating color: UV-resistant redCharacteristic:Maximum core temperature during cable operation: + 90 °CMinim..
High voltage cables XLPE insulated and copper wire shield. Aluminum working core. Available configurations:NA2XS(FL)2Y - 26/45 ÷ 47 (52) kV; according to DIN VDE 0276-632NA2XS(FL)2Y - 36/60 ÷ 69 (72.5) kV; according to DIN VDE 0276-632NA2XS(FL)2Y - 64/110 ÷ 115 (123) kV; according to DIN VDE 0276-632NA2XS(FL)2Y - 76/132 ÷ 138 (145) kV; according to DIN VDE 0276-632NA2XS(FL)2Y - 87/150 ÷ 161 (170) kV; according to DIN VDE 0276-632..
Medium Voltage Cables in XLPE insulation for wind energy with 2-class aluminum conductor, multi-strand, burnished, type RMC. Compliant with DIN VDE 0276-620 and HD 620S2:2010 part 10 section C...
Power cables with aluminum wires, XLPE insulation and PVC coating.PVC insulated and sheathed cables for the transmission of electricity. Designed for installation in the air, in the ground, under water, inside buildings and in cable ducts.Construction:Cores: Aluminum, round class 1 (RE) or round, round compressed class 2 (RM) or sector solid one (SE) or sectoral multi-wire class (SM) according to EN 60228Insulation: A special DIX3 XLPE compound a..
Power cables with aluminum wires, PVC insulation and PE coating.PVC insulated and sheathed cables for the transmission of electricity. Designed for installation in the air, in the ground, under water, inside buildings and in cable ducts.Construction:Cores: Aluminum, round class 1 (RE) or round, round compressed class 2 (RM) or sector solid one (SE) or sectoral multi-wire class (SM) according to EN 60228Insulation: Polwinit type DIV4 according to ..
Halogen free electrical ship cables of medium voltage with low smoke emission, one and three-core. Compliant with IEC 60092-354. Construction:Conductors: Bare copper conductor, round, stranded and compacted Class 2 acc. to BS EN 60228Insulation:extruded semi-conducting conductor screeninsulation XLPE, dry curedextruded semi-conducting insulation screen, fully bondedScreen:semi-conducting tapemetallic screen, double bare copper tapes over each cor..
Installation cables with XLPE insulation and halogen-free plastic coating. Installation cables with crosslinked polyethylene insulation and a sheath of halogen-free thermoplastic material, with low fumes and corrosive gases emission during combustion. Designed for installation in buildings with stricter fire protection requirements. Designed for permanent installation in power and lighting installations, for laying in dry and damp rooms above, un..
Special single-core cables in rubber insulation. The cables are intended for permanent installation in rail vehicles, in pipes and closed ducts. 1.8 / 3 kV cables can be used in control devices and distributors up to 1000V. In power and connection systems, this type of cable gives high resistance to short-circuit and earth-fault overloads.Construction:Cores: Of tinned copper wires, multi-wire flexible classes 5 according to DIN-EN 60228Insulation..
Wires with insulation and rubber coating for lifting equipment, transport equipment and conveyors.Cables are used where there is frequent winding and unwinding during operation, especially with simultaneous tensile load and / or twisting load and / or forced cable routing. Perfect for use in construction, mines, mobile shearers, cranes, conveyors, high mechanical loads, especially at high dynamic tensile loads, e.g. at high acceleration. High res..