5-10 days
Coded Non Contact IDEM IDECODE WPC.
The SPC has been designed with a CODED MAGNETIC Actuation adnd SWITCHING TOLERANCE of up to 14mm. Designed with a specification of 80°C the SPC has been designed to work up to 100°C.
The slim fitting of the WPC makes it a suitable safety switch for all industry applications. Manufactured with a durable polyester housing and there's no moving parts - survives shock and vibration.
Specifications:
Standards:
- ISO14119
- EN60947-5-1
- EN60204-1
- ISO13849-1
- EN62061
- UL508
Safety Classification and Reliability Data:
- ISO13849-1: Up to PLe Category 4
- EN62061: Up to SIL3
- PFHd: 8.71 x 10-11
- Proof Test Interval (Life): 20 years
- MTTFd: 866 years
- Safety Channel 1 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 2 NC: 24Vdc 0.2A Max. Rating
- Safety Channel 3 NO: 24Vdc 0.2A Max. Rating
- Minimum Switched Current: 10Vdc 1mA
- Dielectric Withstand: 250Vac
- Insulation Resistance: 100 Mohms
- Recommended Setting Gap: 5mm
- Switching Distance: Sao 10mm Close
- Switching Distance (Target to Target): Sar 20mm Open
- Tolerance to Misalignment: 5mm in any direction from 5mm setting gap
- Switching Frequency: 1.0Hz maximum
- Approach Speed: 200mm/min to 1000mm/sec
- Body Material: UL approved polyester
- Operating Temperature: -25°C ~ 80°C
- Enclosure Protection: IP67; IP69K
- Shock Resistance: IEC68-2-27; 11ms; 30g
- Vibration Resistance: IEC 68-2-6; 10-55Hz; 1mm
- Cable Type: PVC 6 or 8 core 6mm OD; Conductors 0.25mm2
- Mounting Bolts: 2xM4 Tightening torque 1.0Nm
- Mounting Position: Any
Warranty: 36 months
Ordering Information:
- Idecode WPC 112013 - Cable Length: 2M; Circuits: 2NC
- Idecode WPC 112014 - Cable Length: 5M; Circuits: 2NC
- Idecode WPC 112015 - Cable Length: 10M; Circuits: 2NC
- Idecode WPC 112016 - Cable Length: QC-M12; Circuits: 2NC
- Idecode WPC 112017 - Cable Length: 2M; Circuits: 2NC, 1NO
- Idecode WPC 112018 - Cable Length: 5M; Circuits: 2NC, 1NO
- Idecode WPC 112019 - Cable Length: 10M; Circuits: 2NC, 1NO
- Idecode WPC 112020 - Cable Length: QC-M12; Circuits: 2NC, 1NO
- Idecode WPC 112105 - Cable Length: 2M; Circuits: 3NC
- Idecode WPC 112106 - Cable Length: 5M; Circuits: 3NC
- Idecode WPC 112107 - Cable Length: 10M; Circuits: 3NC
- Idecode WPC 112108 - Cable Length: QC-M12; Circuits: 3NC
Industrial grade | |
Casing | Plastic |
IP rating | IP67, IP69K |
Operating temperature | -25°C to 80°C |
Input voltage | 24VDC |
Manufacturer's warranty | 36 months |