INMBSLGE001R000 LG VRF to Modbus RTU RS-485 gateway for control and monitoring

INMBSLGE001R000 is LG VRF to Modbus RTU RS-485 gateway for control and monitoring, temp. 0…40°C.

INMBSLGE001R000 - LG VRF to Modbus RTU RS-485 gateway for control and monitoring
3 year warranty 5-7 days
INMBSLGE001R000 LG VRF to Modbus RTU RS-485 gateway for control and monitoring
  • Stock: 5-7 days
  • Brand: Intesis
  • Model: INMBSLGE001R000
1 137,87 zł
2 pieces or more 1 080,98 zł
5 pieces or more 1 058,22 zł
10 pieces or more 1 024,08 zł
26 pieces or more 967,19 zł
51 pieces or more 864,78 zł
A proven choice for industrial installations.
Ask for compatibility and model selection.
Additional discounts for registered customers.

Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports

If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.

  • Device User Manual
  • CE Declaration of Conformity (EU Declaration of Conformity)
  • Mechanical DrawingsCAD (STEP/DWG) or high-quality PDF
  • Additional Certificates and Test Reports (if available for the model)
Request a package: User manual, CE declaration, CAD, PDF, certificates, test reports

LG VRF to Modbus RTU (RS-485) gateway – bi-directional monitoring & control, INMBSLGE001R000

IntesisBox INMBSLGE001R000 is an industrial communication gateway that integrates LG VRF air conditioning systems with Modbus RTU (EIA485 / RS-485) networks. It enables standardized HVAC control and feedback through Modbus registers, making it a practical interface for PLC, SCADA and BMS environments where interoperability and repeatable commissioning matter.

The communication is fully bi-directional. From the Modbus side you can manage core AC functions (e.g., operating mode, fan speed, temperature setpoint) and at the same time read back the unit’s status. In addition to normal supervision, the gateway can expose errors, alarms and selected internal variables, allowing you to build service-oriented logic, notifications and energy-saving strategies within the control system.

INMBSLGE001R000 is wired directly to the indoor unit, which helps ensure stable communication and simplifies installation. Commissioning is typically fast—mainly wiring the gateway to the AC unit and setting parameters via DIP switches (configuration is also possible via Modbus RTU). No configuration software is required, and no external power supply is needed in typical applications. A consistent Modbus register mapping across this gateway family can also reduce engineering time on multi-brand HVAC projects.

Manufacturer designation change
Old code: LG-RC-MBS-1
New code: INMBSLGE001R000
Technically identical product – only the name / SKU has changed.

Product features

  • Bi-directional LG VRF ↔ Modbus RTU (RS-485) integration for monitoring and control.
  • Direct indoor unit connection for stable communication and access to operational feedback.
  • Fast setup: configuration via DIP switches and via Modbus RTU.
  • No external power supply required in typical applications.
  • RS-485 scalability: up to 63 LG-RC-MBS-1 devices on the same Modbus RTU network.
  • Support for error/alarm handling and internal variable readout in the supervisory system.
  • Allows simultaneous operation via IR and wired remote controllers as well as via Modbus RTU.

Technical specification

Features (from documentation):

  • Reduced dimensions
  • Quick and easy installation
  • No external power supply required
  • Direct connection to Modbus RTU network (EIA485). Up to 63 LG-RC-MBS-1 devices can be connected to the same network
  • Direct connection to indoor AC units
  • Configuration via built-in DIP switches and via Modbus RTU
  • Total control and supervision
  • Real internal variable states of the AC unit
  • Allows simultaneous use of IR and wired remote controller as well as Modbus RTU

Specification:

  • Dimensions: 93 x 53 x 58 mm
  • Weight: 85 g
  • Current consumption: 80 mA
  • Operating temperature: 0°C ~ 40°C
  • Storage temperature: -40°C ~ 85°C
  • Operating humidity: <95% RH, non-condensing
  • Storage humidity: <95% RH, non-condensing
  • Isolation voltage: 1000 VDC
  • Insulation resistance: 1000 MΩ
  • Modbus media: compatible with Modbus RTU network - EIA485

Warranty: 36 months

INMBSLGE001R000 – LG VRF to Modbus RTU (RS-485) gateway – technical drawing

Product code: INMBSLGE001R000


General technical parameters
Protocol supportModbus RTU
Industrial grade
Manufacturer's warranty3 years

Write a review