Menu
Your Cart

NSHTÖU-J 0.6/1kV

NSHTÖU-J 0.6/1kV
To be confirmed
NSHTÖU-J 0.6/1kV
0,00 zł

Wires with insulation and rubber coating for lifting equipment, transport equipment and conveyors.

Cables are used where there is frequent winding and unwinding during operation, especially with simultaneous tensile load and / or twisting load and / or forced cable routing. Perfect for use in construction, mines, mobile shearers, cranes, conveyors, high mechanical loads, especially at high dynamic tensile loads, e.g. at high acceleration. High resistance to oils, greases, chemicals and moisture, to the spread of flame.

Construction:

  • Core: Copper tinned round multi-wire class 5 according to DIN-EN 60228
  • Insulation: Rubber compound type 3GI3 according to VDE 0207 part 20
  • Inner coating: Rubber compound type GM1b according to VDE 0207 part 21
  • Reinforcement braid: With plastic thread
  • Outer shell: 5GM3 rubber compound according to VDE 0207 part. 21
  • Coating color: Black
  • Identification of veins:
    • 3-wire: green-yellow, blue, brown
    • 4-wire: green-yellow, brown, black, gray
    • 5-wire: green-yellow, blue, brown, black, gray
    • over 5 veins: green-yellow (in the outer layer), other blacks with digital overprint

Characteristic:

  • Maximum temperature of the conductor during cable operation: + 90°C
  • The minimum ambient temperature for laying cables: - 25°C
  • Maximum core temperature during short circuit: + 200°C
  • Maximum permissible load: 15 N per mm² of copper cross-section
  • Resistance to flame spread: PN-EN 60332-1-2
  • Test voltage testing: 2500V
  • Standard packaging: On drums of 500 m or 1000 m. It is possible to offer other lengths of sections and types of packaging

Compliant with: DIN VDE 0250-814


Industrial grade
Operating temperature to 90°C
Cable parameters
Minimum bending radius 1D, 2D, 3D, 4D, 6D, 7.5D, 5D, 10D, 12D, 15D
Core Copper
Insulation Rubber
Installation temperature -25°C to 90°C
Inner coating Rubber compound
Outer coating Rubber compound
Maximum short circuit temperature 200°C
Test voltage 2.5 kV
Standard packaging On drums
Resistance to flame spread EN 60332-1-2
Outer diameter [mm] 13.3, 14.1, 14.7, 15.0, 16.5, 16.9, 17.4, 18.0, 18.1, 18.5, 18.6, 19.2, 19.6, 19.9, 20.3, 22.5, 24.2, 25.0, 27.3, 28.0, 28.9, 29.4, 29.6, 31.1, 31.5, 32.2, 32.3, 32.5, 33.1, 33.2, 33.5, 33.7, 34.9, 37.3, 38.9, 42.1, 42.8, 43.4, 46.5, 50.0, 51.7, 52.3, 54.3, 57.2, 58.7, 63.4, 64.2, 69.0
Cable weight [kg/km] 211, 244, 269, 272, 346, 366, 392, 394, 404, 439, 463, 478, 520, 544, 571, 727, 761, 878, 902, 961, 1004, 1012, 1164, 1185, 1242, 1301, 1391, 1400, 1641, 1698, 1820, 1821, 1837, 2021, 2249, 2596, 3213, 3335, 4165, 4458, 5016, 5272, 5562, 6401, 6873, 8350, 9126, 10555
Working conductor cross section [mm2] 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 240.0

Write a review

Note: HTML is not translated!
Bad Good

We know that choosing the right product can be difficult. Get a free consultation with a technical expert and make the right decision!

We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.