To be confirmed
OnGcrekgż-G (Z) 18/30 kV
- Stock: To be confirmed
- Brand: TELE-FONIKA Kable
- Model: OnGcrekgż-G (Z) 18/30 kV
0,00 zł
Mining wires shielded for rated voltage 18/30 kV.
Construction:
- Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228
- Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989
- Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989
- The color of the insulation of the veins: Natural
- Screen on the insulation of working cores: GP semiconductor rubber according to PN-E 29100: 1989
- Tire inner layer: Of rubber type ON-4 according to PN-E-29100: 1989
- Strengthening braid: Made of polyamide yarn
- Tire outer layer: Of rubber type ON-4 according to PN-E-29100: 1989
- Tire color: Red or black
Characteristic:
- Application: For powering mining open-cast mining machines, for work in continuous coiling and unwinding conditions
- Explanation of the conductor symbol: OnGcrekgż-G (Z) - power cable with copper conductors, with heat-resistant, reduced rubber insulation (Gcr) and flame retardant rubber (On), with shielded conductors semi-conductive rubber (ekgż), mining (-G) , for folding and developing ((Z))
- Example of wire marking: OnGcrekgż-G (Z) four-wire conductor for 18/30 kV voltage with a cross section of 70 mm2 working wires, 35 mm2 protective conductor: OnGcrekgż-G (Z) 3x70 + 3x35 / 3 mm2 18/30 kV cable according to ZN- 95 / MP-13-K104
- Maximum core temperature during insulation operation: + 90 °C
- Working range in the temperature range: -40 °C to + 50 °C
- Minimum bending radius: 10 x D, D - outer diameter of the wire
- Test voltage: 43 kV working vein
- Packing: Cable drums
Compliant with: ZN-95 / MP-13-K 104
Industrial grade | |
Operating temperature | -40°C to 90°C, -40°C to 50°C |
Cable parameters | |
Minimum bending radius | 12D |
Core | Copper |
Shield | Semi-conductive rubber |
Insulation | Heat-resistant rubber |
Test voltage | 43 kV |
Standard packaging | On drums |
Tire | Rubber |
Outer diameter [mm] | 51.5, 54.0, 56.5, 58.1, 63.8, 67.6, 73.6, 75.9, 79.9, 86.1 |
Cable weight [kg/km] | 3325, 3800, 4300, 4725, 5875, 6875, 8375, 9525, 10825, 12775 |
Working conductor cross section [mm2] | 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0 |